SPONTANEOUS DELAYED PROXIMAL MIGRATION OF ENTERPRISE STENT AFTER STAGED TREATMENT OF WIDE- NECKED BASILAR ANEURYSM

Neurosurgery ◽  
2009 ◽  
Vol 64 (5) ◽  
pp. 1012-1012 ◽  
Author(s):  
Sean D. Lavine ◽  
Philip M. Meyers ◽  
E. Sander Connolly ◽  
Robert S. Solomon

Abstract OBJECTIVE To document a unique technical issue with a relatively newly released intravascular stent used for adjunctive treatment of wide-necked cerebral aneurysms. CLINICAL PRESENTATION A 48-year-old woman with a sister who had a large unruptured wide-necked basilar aneurysm underwent screening evaluation that revealed a nearly identical aneurysm. She also harbored small unruptured right superior cerebellar and left anterior cerebral artery aneurysms. INTERVENTION Endovascular treatment of the 11.5-mm basilar aneurysm was performed in a staged manner. Stent placement was performed first, followed by delayed coil embolization of the aneurysm 9 weeks later. Follow-up angiography at the time of the second procedure revealed significant spontaneous proximal migration of the Enterprise Vascular Reconstruction Device and Delivery System (Cordis Neurovascular, Inc., Miami Lakes, FL) with the distal extent of the device migrating from the right P2 segment into the neck of the aneurysm. Coil embolization was performed despite migration of the vascular reconstruction device. CONCLUSION The use of stents in the endovascular treatment of cerebral aneurysms has vastly improved our ability to treat complex lesions. Technical issues remain with these devices, and description of this event may alter the way we use the Enterprise Vascular Reconstruction Device and Delivery System in terms of staging procedures, and when evaluating the particular vascular anatomy of the individual patient with special attention to parent artery vessel size.

2015 ◽  
Vol 21 (2) ◽  
pp. 178-183 ◽  
Author(s):  
Hideaki Ishihara ◽  
Shoichiro Ishihara ◽  
Jun Niimi ◽  
Hiroaki Neki ◽  
Yoshiaki Kakehi ◽  
...  

Objective Advances in vascular reconstruction devices and coil technologies have made coil embolization a popular and effective strategy for treatment of relatively wide-neck cerebral aneurysms. However, coil protrusion occurs occasionally, and little is known about the frequency, the risk factors and the risk of thrombo-embolic complications. Method We assessed the frequency and the risk factors for coil protrusion in 330 unruptured aneurysm embolization cases, and examined the occurrence of cerebral infarction by diffusion-weighted magnetic resonance imaging (DW-MRI). Result Forty-four instances of coil protrusion were encountered during coil embolization (13.3% of cases), but incidence was reduced to 33 (10% of cases) by balloon press or insertion of the next coil. Coil protrusion occurred more frequently during the last phase of the procedure, and both a wide neck (large fundus to neck ratio) (OR = 1.84, P = 0.03) and an inadequately stable neck frame (OR = 5.49, P = 0.0007) increased protrusion risk. Coil protrusions did not increase the incidence of high-intensity lesions (infarcts) on DW-MRI (33.3% vs 29% of cases with no coil protrusion). However, longer operation time did increase infarct risk ( P = 0.0003). Thus, tail or loop type coil protrusion did not increase the risk of thrombo-embolic complications, if adequate blood flow was maintained. Conclusion Coil protrusion tended to occur more frequently in cases of wide-neck aneurysms with loose neck framing. Moderate and less coil protrusion carries no additional thrombo-embolic risk, if blood flow is maintained, which can be aided by additional post-operative antiplatelet therapy.


2008 ◽  
Vol 108 (6) ◽  
pp. 1230-1240 ◽  
Author(s):  
Thomas R. Marotta ◽  
Thorsteinn Gunnarsson ◽  
Ian Penn ◽  
Donald R. Ricci ◽  
Ian Mcdougall ◽  
...  

Object The authors describe a novel device for the endovascular treatment of intracranial aneurysms, the endovascular clip system (eCLIPs). Descriptions of the device and its delivery system as well as the results of flow model tests and the treatment of experimental aneurysms are provided. Methods The eCLIPs comprises a flexible hybrid implantable device (an anchor and a covered leaf) and a balloon catheter delivery system, designed to be positioned and activated in the parent vessel in such a way that the covered portion will abut the aneurysm neck. The eCLIPs was subjected to testing in glass, elastomeric, and cadaveric flow models to determine its navigability, orientation, and activation compared with commercially available stents. In a second experiment, 8 carotid artery sidewall aneurysms in swine were treated using eCLIPs. The degree of occlusion was observed on angiography immediately following and 30 days after device activation, and a histological analysis was performed at 30 days. Results The device could navigate tortuous glass models and human cadaveric vessels. Compared with commercially available stents, the eCLIPs performed well. It could be navigated, oriented, and activated easily and reliably. With regard to the 8 porcine experimental aneurysms, immediate postactivation angiograms confirmed complete occlusion of 4 lesions and near occlusion of the other 4. Angiographic follow-up at 30 days postactivation showed occlusion of all 8 aneurysms and patency of all parent vessels. Histopathological analysis revealed aneurysm healing, with smooth-muscle cells growing across the lesion neck to allow reendothelialization. Conclusions Aneurysm occlusion with a single extrasaccular endovascular device has potential advantages. The authors believe that eCLIPs may prove to be a useful tool in the endovascular treatment of cerebral aneurysms. The system should reduce risks associated with coiling, procedure time, costs, and radiation exposure. The device satisfactorily occluded 8 experimental sidewall aneurysms. The observed healing pattern is similar to that seen after microsurgical clipping.


2012 ◽  
Vol 18 (3) ◽  
pp. 326-332 ◽  
Author(s):  
P. Gölitz ◽  
T. Struffert ◽  
M. Arc Saake ◽  
F. Knossalla ◽  
A. Doerfler

This investigation aimed to demonstrate the potential of intraprocedural angiographic CT in monitoring complex endovascular coil embolization of direct carotid cavernous fistulas. Angiographic CT was performed as a dual rotational 5 s run with intraarterial contrast medium injection in two patients during endovascular coil embolization of direct carotid cavernous fistulas. Intraprocedural angiographic CT was considered helpful if conventional 2D series were not conclusive concerning coil position or if a precise delineation of the parent artery was impossible due to a complex anatomy or overlying coil material. During postprocessing multiplanar reformatted and dual volume images of angiographic CT were reconstructed. Angiographic CT turned out to be superior in the intraprocedural visualization of accidental coil migration into the parent artery where conventional 2D-DSA series failed to reliably detect coil protrusion. The delineation of coil protrusion by angiographic CT allowed immediate correct coil repositioning to prevent parent artery compromising. Angiographic CT can function as a valuable intraprocedurally feasible tool during complex coil embolizations of direct carotid cavernous fistulas. It allows the precise visualization of the cerebral vasculature and any accidental coil protrusion can be determined accurately in cases where conventional 2D-DSA series are unclear or compromised. Thus angiographic CT might contribute substantially to reduce procedural complications and to increase safety in the management of endovascular treatment of direct carotid cavernous fistulas.


2019 ◽  
Vol 25 (4) ◽  
pp. 454-459
Author(s):  
Changchun Jiang ◽  
Wei Wang ◽  
Baojun Wang ◽  
Yuechun Li ◽  
Guorong Liu ◽  
...  

Background Rupture of cerebral aneurysm is an inevitable complication during embolization, followed by subsequent acute subarachnoid hemorrhage or intracranial hematoma, and results in the aggravation of a patient’s condition. In particular, for patients who have had a ruptured aneurysm, urgent treatment strategies are required during operation. The most common hemostatic methods seen in clinical practices are as follows: after lowering the blood pressure, we continue to embolize the aneurysms with detachable coils as soon as possible or inject with Glubran/Onyx embolization liquids, as well as use a balloon catheter to temporarily block the blood supply. If the conditions are permissible, a balloon guiding catheter may even be used to restrict the proximal blood flow. At times, due to limitations of these methods, neurosurgeons are requested to perform craniotomy to treat the hemostasis. However, the delayed transition often leads to rapid deterioration of the patient’s condition and even death due to cerebral hernia. Case description We herein presented two cases of ruptured cerebral aneurysms to provide an alternative method for hemostasis and to save the lives of patients as much as possible. In an extremely urgent situation (conventional treatment is ineffective), we successfully saved the patient’s life by injecting lyophilizing thrombin powder (LTP) solution into the aneurysmal sac and the parent artery through a microcatheter. Conclusions To our knowledge, this is the first report of successful hemostasis during coil embolization of ruptured cerebral aneurysm with LTP. Further prospective studies are needed to confirm the safety and efficacy of LTP in cerebrovascular interventional therapy.


Author(s):  
Robert M. King ◽  
Juyu Chueh ◽  
Imramsjah M. J. van der Bom ◽  
Christine F. Silva ◽  
Ajay K. Wakhloo ◽  
...  

Stent implantation has expanded the endovascular treatment of intracranial aneurysms to those with widenecks, that were previously unfavorable to coil embolization. Past studies have found that several mechanisms including stent-induced endothelization and hemodynamic changes due to alteration in vessel geometry may contribute to stable clot formation within the aneurysmal sac and aid in aneurismal healing [1,2]. Change in the angle of the parent arteries after stent-assisted coil embolization of anterior communicating artery (Acom) aneurysms has been measured on projection angiograms; however, use of 2D angiographic datasets to describe changes of vessel angle in 3D may result in significant error. The goal of this study was to quantitatively characterize the change in the radius of curvature (RC) of the parent artery induced by the implantation of an intracranial stent in 3D.


2012 ◽  
Vol 18 (4) ◽  
pp. 442-448 ◽  
Author(s):  
I. Ioannidis ◽  
N. Nasis ◽  
A. Andreou

Dissecting aneurysms of the posterior inferior cerebellar artery (PICA) distal to its origin from vertebral artery (VA) are very rare. Although rare, they associated with a high risk of rebleeding and they present a therapeutic challenge. This study reviewed the clinical presentations, angiographic characteristics of dissecting aneurysms of the PICA and to assess the clinical and angiographic outcomes of patients who underwent endovascular treatment. Ten patients with ten dissecting aneurysms who underwent endovascular treatment were identified in the clinical records of a single medical center from January 2000 to December 2010. The mean follow-up duration was 2.8 years. All patients presented with subarachnoid hemorrhage (SAH). They all underwent endovascular treatment, which included occlusion of the dissected segment and the parent artery after detailed angiographic evaluation of the vascular anatomy, and test occlusion of the PICA. In all patients the endovascular treatment was successfully completed without procedure related complications. Long-term follow-up studies in seven out of ten patients showed complete occlusion of the aneurysm with no new neurologic deficits. The clinical outcome was good in eight cases, whereas two patients with poor clinical condition at admission died during their initial hospital stay. Endovascular occlusion of the parent vessel and the dissected segment is relatively safe treatment option for dissecting aneurysms of the PICA distal to its origin.


Author(s):  
Ehab Mahmoud ◽  
Samuel Lenell ◽  
Christoffer Nyberg ◽  
Ljubisa Borota

A good working view is critical for safe and successful endovascular treatment of cerebral aneurysms. In a few cases, endovascular treatment of cerebral aneurysms may be challenging due to difficulty in obtaining a proper working view. In this report of 6 cases, we described the advantage of using a distal intracranial catheter (DIC) to achieve better visualization of cerebral aneurysms hidden by a parent artery or its branches. Between September 2017 and January 2021, we treated 390 aneurysms with endovascular techniques. In 6 cases in which it was difficult to obtain a proper working view, the DIC was placed distally close to the aneurysm in order to remove the parent artery projection from the working view and obtain better visualization of the aneurysm. Clinical and procedural outcomes and complications were evaluated. The position of the DIC was above the internal carotid artery siphon in the 6 cases. All aneurysms were successfully embolized. Raymond–Roy class 1 occlusion was achieved in all 4 unruptured aneurysms, while the result was class 2 in the 2 ruptured aneurysms. Placement of the DIC was atraumatic without dissections or significant catheter-induced vasospasm in all patients. Transient dysphasia was seen in 2 cases and transient aphasia in 1. Using this technique, we have found it possible to better visualize the aneurysm sac or neck and thereby treat cases we otherwise would have considered untreatable.


Author(s):  
Haithem Babiker ◽  
Justin Ryan ◽  
L. Fernando Gonzalez ◽  
Felipe Albuquerque ◽  
Daniel Collins ◽  
...  

Coil embolization is the most common endovascular treatment for cerebral aneurysms at many centers [1]. Nevertheless, the coiling of wide-neck aneurysms is a challenge. Incomplete filling of the aneurysmal sac due to coil configuration challenges and aneurysmal growth can often lead to recurrence. To assist treatment with coils, clinicians may deploy a high porosity stent in a staged process to act as a supporting bridge for coils. The stent is first deployed across the aneurysmal neck, and multiple coils are then deployed into the aneurysmal sac 6–8 weeks later [2]. Under certain circumstances, coil deployment is not possible and high porosity stents alone are used for treatment [2–3].


Neurosurgery ◽  
2020 ◽  
Author(s):  
Alexander Sirakov ◽  
Krasimir Minkin ◽  
Marin Penkov ◽  
Kristian Ninov ◽  
Vasil Karakostov ◽  
...  

Abstract Background Wide-necked cerebral aneurysms in the setting of acute subarachnoid hemorrhage (SAH) remain difficult to treat with endovascular methods despite recent progress in the neuroendovascular field. Objective To evaluate the effectiveness and safety of the Comaneci device (Rapid Medical, Israel) in endovascular coil embolization of acutely ruptured, wide-necked sidewall, or bifurcation cerebral aneurysms. Methods We retrospectively reviewed 45 anterior communicating artery, 24 internal carotid artery, 21 middle cerebral artery bifurcation, 15 anterior cerebral artery, and 13 posterior circulation aneurysms, which were treated using Comaneci-assisted coil embolization from August 2017 to January 2019. We evaluated procedural complications, clinical outcomes, and mid-term angiographic follow-up. Immediate and 90 d-clinical outcome and radiological follow-up were obtained in all patients. Results Comaneci-assisted coil embolization was performed in 118 acutely ruptured aneurysms. The technique was carried out successfully in all cases. Simultaneous application of 2 separated Comaneci devices was performed in 8/118 cases (6.77%). Periprocedural thromboembolic complications related to the device were seen in 7/118 cases (5.93%) and severe vasospasm of the parent artery after manipulation of the Comaneci device occurred in 5/118 cases (4.2%). The procedural-related morbidity rate was 2.54%, and there was no procedural related mortality. Among the available survivors, angiographic follow-ups were obtained at 3 and 6 mo, and complete aneurysmal obliteration was confirmed in 81/112 (72.3%) and 75/112 (66.9%) cases, respectively. Mid-term follow-up reviewed total recanalization rate of 14.28%. Conclusion Comaneci-assisted embolization of wide-necked intracranial aneurysms in patients presenting with acute SAH is associated with high procedural safety and adequate occlusion rates. Furthermore, dual antiplatelet therapy can be safely avoided in this patient group.


Sign in / Sign up

Export Citation Format

Share Document