A novel endovascular clip system for the treatment of intracranial aneurysms: technology, concept, and initial experimental results

2008 ◽  
Vol 108 (6) ◽  
pp. 1230-1240 ◽  
Author(s):  
Thomas R. Marotta ◽  
Thorsteinn Gunnarsson ◽  
Ian Penn ◽  
Donald R. Ricci ◽  
Ian Mcdougall ◽  
...  

Object The authors describe a novel device for the endovascular treatment of intracranial aneurysms, the endovascular clip system (eCLIPs). Descriptions of the device and its delivery system as well as the results of flow model tests and the treatment of experimental aneurysms are provided. Methods The eCLIPs comprises a flexible hybrid implantable device (an anchor and a covered leaf) and a balloon catheter delivery system, designed to be positioned and activated in the parent vessel in such a way that the covered portion will abut the aneurysm neck. The eCLIPs was subjected to testing in glass, elastomeric, and cadaveric flow models to determine its navigability, orientation, and activation compared with commercially available stents. In a second experiment, 8 carotid artery sidewall aneurysms in swine were treated using eCLIPs. The degree of occlusion was observed on angiography immediately following and 30 days after device activation, and a histological analysis was performed at 30 days. Results The device could navigate tortuous glass models and human cadaveric vessels. Compared with commercially available stents, the eCLIPs performed well. It could be navigated, oriented, and activated easily and reliably. With regard to the 8 porcine experimental aneurysms, immediate postactivation angiograms confirmed complete occlusion of 4 lesions and near occlusion of the other 4. Angiographic follow-up at 30 days postactivation showed occlusion of all 8 aneurysms and patency of all parent vessels. Histopathological analysis revealed aneurysm healing, with smooth-muscle cells growing across the lesion neck to allow reendothelialization. Conclusions Aneurysm occlusion with a single extrasaccular endovascular device has potential advantages. The authors believe that eCLIPs may prove to be a useful tool in the endovascular treatment of cerebral aneurysms. The system should reduce risks associated with coiling, procedure time, costs, and radiation exposure. The device satisfactorily occluded 8 experimental sidewall aneurysms. The observed healing pattern is similar to that seen after microsurgical clipping.

2006 ◽  
Vol 12 (1) ◽  
pp. 31-35 ◽  
Author(s):  
K.F. Layton ◽  
H.J. Cloft ◽  
D.F. Kallmes

Perforation of intracranial aneurysms during endovascular treatment with platinum micro-coils is a well-known and serious complication reported to occur in 2–4% of patients. Inflation of a remodelling balloon across the aneurysm neck or within the proximal parent vessel is an additional technique that theoretically might be useful to reduce flow within the aneurysm and achieve hemostasis. In the case reports that follow, we present our experience using this technique for managing intraprocedural aneurysm rupture.


2005 ◽  
Vol 18 (2) ◽  
pp. 1-5 ◽  
Author(s):  
Sepehr Sani ◽  
Kirk W. Jobe ◽  
Demetrius K. Lopes

Object Until recently, wide-necked aneurysms were not considered amenable to treatment with coil embolization. The recent introduction of intracranial stents has provided a method of preventing coil migration out of wide-necked aneurysms. The Neuroform2 Treo is a modification of the Neuroform stent; the new version has a higher metal/artery ratio. The authors' initial experience with the use of this stent in combination with coil embolization to treat wide-necked intracranial aneurysms is reported and technical considerations are discussed. Methods The authors' first 10 consecutive patients with wide-necked intracranial aneurysms were included in this study. Inclusion criteria restricted the group to adult patients with wide-necked intracranial aneurysms (ruptured and unruptured lesions). A wide neck was defined as a dome/neck ratio of less than 2 or a neck that was 4 mm or wider as measured on angiograms. Immediate postprocedure angiography studies were performed to determine successful coil occlusion of the aneurysm as well as patency of the parent vessel. Six-month follow-up angiograms were obtained in all patients. Ten aneurysms with poor dome/neck ratios (< 2) were studied in 10 patients. In all cases the stent was delivered to the aneurysm site and positioned without difficulty. No branch artery compromise was observed. A technical difficulty occurred in one case, with prolapse of a coil into the parent vessel, which was successfully corrected with no adverse clinical effects. There were no clinical or neurological complications associated with endovascular treatment of aneurysms in this series. One patient required further coil embolization because of findings on the 6-month follow-up cerebral angiogram. Conclusions The Neuroform2 Treo navigates similarly to the Neuroform2, with the advantage of increased aneurysm neck coverage. This feature may lower the retreatment rates for wide-necked cerebral aneurysms.


1997 ◽  
Vol 3 (2_suppl) ◽  
pp. 114-117
Author(s):  
K. Irie ◽  
W. Taki ◽  
I. Nakahara ◽  
N. Sakai ◽  
F. Isaka ◽  
...  

The aneurysmal neck size seems to be an import ant factor in the endovascular treatment outcome4,5. The purpose of the present study was to measure aneurysm neck size on angiographic films, and compare the measured value with the extent of intra-aneurysmal occlusion performed with detachable coils. The subjects were 22 patients with intracranial aneurysms treated using detachable coils. The cases were divided into two groups according to the aneurysmal neck size, 4 mm being the discriminating value for small neck. The neck of the aneurysm was successfully occluded in 19 of 22 patients. Ten aneurysms had a small neck and 9 aneurysms had a wide neck. Complete aneurysm occlusion was observed in 70% of small neck aneurysms and 25% of wide neck aneurysms. The results support that the size of the aneurysm neck correlates well with the effectiveness of endovascular treatment.


2010 ◽  
Vol 67 (3) ◽  
pp. ons-ons ◽  
Author(s):  
Thomas J. Gruber ◽  
Christopher S. Ogilvy ◽  
Erik F. Hauck ◽  
Elad I. Levy ◽  
L. Nelson Hopkins ◽  
...  

Abstract OBJECTIVE: Endovascular treatment of large intracranial aneurysms arising from a fenestrated parent vessel may prove particularly difficult. We present a case of a large, broad-based aneurysm arising from a proximal basilar artery (BA) fenestration treated with the wafflecone technique. Technical nuances and indications for this treatment option are reviewed. CLINICAL PRESENTATION: A 38-year-old man presented with headache, blurred vision, and dizziness. Angiography demonstrated an 11 × 14-mm BA aneurysm associated with the proximal portion of a BA fenestration. TECHNIQUE: A 28 × 4.5-mm Enterprise stent was placed from the right vertebral artery directly into the aneurysm. The stent tines were allowed to flare out in the aneurysm neck creating the “waffle cone.” The aneurysm was then coiled with a series of Presidio coils. CONCLUSION: Use of the waffle-cone technique for stent placement resulted in nearly complete embolization of the aneurysm, retention of the entire coil mass in the dome, and preservation of flow through both vertebral arteries and both limbs of the fenestration.


2013 ◽  
Vol 19 (1) ◽  
pp. 16-20 ◽  
Author(s):  
I. Oran ◽  
C. Çinar ◽  
H. Bozkaya ◽  
F.H. Beşir

Embolization of wide-necked and/or giant aneurysms may fail due to the inability to pass across the aneurysm neck. We describe the rapid bull-back technique used in four patients in which a small diameter microcatheter with the aid of a hydrophilic microguidewire was navigated along the inner surface of the aneurysm, making a loop in the dome, exiting the neck to reach distal intracranial vessels. After withdrawal of microguidewire, the microcatheter is pulled back rapidly up to a predetermined length. This maneuver results in elimination of the loop, straightening the microcatheter to allow an exchange procedure for another device to cross the neck distally and continue the embolization procedure. The rapid pull-back technique is useful during the endovascular treatment of wide-necked and/or giant aneurysms as it helps to achieve reliable access to the distal parent vessel with the microcatheter. This is of increasing importance since an increasing number of aneurysms will be treated in the future with refinements in various intracranial stents.


2019 ◽  
Vol 30 (4) ◽  
pp. 817-826
Author(s):  
Fei Peng ◽  
Xin Feng ◽  
Xin Tong ◽  
Baorui Zhang ◽  
Luyao Wang ◽  
...  

Abstract Purpose To investigate the long-term clinical and angiographic outcomes and their related predictors in endovascular treatment (EVT) of small (<5 mm) ruptured intracranial aneurysms (SRA). Methods The study retrospectively reviewed patients with SRAs who underwent EVT between September 2011 and December 2016 in two Chinese stroke centers. Medical charts and telephone call follow-up were used to identify the overall unfavorable clinical outcomes (OUCO, modified Rankin score ≤2) and any recanalization or retreatment. The independent predictors of OUCO and recanalization were studied using univariate and multivariate analyses. Multivariate Cox proportional hazards models were used to identify the predictors of retreatment. Results In this study 272 SRAs were included with a median follow-up period of 5.0 years (interquartile range 3.5–6.5 years) and 231 patients with over 1171 aneurysm-years were contacted. Among these, OUCO, recanalization, and retreatment occurred in 20 (7.4%), 24 (12.8%), and 11 (7.1%) patients, respectively. Aneurysms accompanied by parent vessel stenosis (AAPVS), high Hunt-Hess grade, high Fisher grade, and intraoperative thrombogenesis in the parent artery (ITPA) were the independent predictors of OUCO. A wide neck was found to be a predictor of recanalization. The 11 retreatments included 1 case of surgical clipping, 6 cases of coiling, and 4 cases of stent-assisted coiling. A wide neck and AAPVS were the related predictors. Conclusion The present study demonstrated relatively favorable clinical and angiographic outcomes in EVT of SRAs in long-term follow-up of up to 5 years. THE AAPVS, as a morphological indicator of the parent artery for both OUCO and retreatment, needs further validation.


Neurosurgery ◽  
2009 ◽  
Vol 65 (5) ◽  
pp. E1007-E1008 ◽  
Author(s):  
Demetrius K. Lopes ◽  
Kalani Wells

Abstract OBJECTIVE To describe a novel stent remodeling technique for the coiling of ruptured wide-neck cerebral aneurysms. CLINICAL PRESENTATION A 46-year-old man presented with acute subarachnoid hemorrhage (Hunt and Hess grade IV), intracerebral hemorrhage, and hydrocephalus. Cerebral angiography revealed a wide-neck small anterior communicating artery aneurysm. Conventional coiling was not successful because of coil instability and compromise of the dominant anterior cerebral artery. TECHNIQUE A 6-French shuttle sheath (Cook Medical, Indianapolis, IN) was advanced from a right femoral approach into the right common carotid artery. To protect the parent vessel during coiling without compromising blood flow, a Prowler Select Plus catheter (Cordis Corporation, Bridgewater, NJ) was navigated across the aneurysm neck. Subsequently, an Enterprise stent (22-mm length; Cordis Corporation) was partially deployed across the aneurysm's wide neck. It was very important to watch the distal markers of the stent and lock the stent delivery wire to the Prowler Select Plus with a hemostatic valve once the stent was halfway deployed. This maneuver was essential to prevent further deployment of the stent. The SL-10 microcatheter and Synchro 14 wire (Boston Scientific, Natick, MA) were carefully navigated to the aneurysm passing through the partially deployed stent. Coils were then delivered to the aneurysm using the stent as a scaffold. After coiling, the SL-10 microcatheter was removed and the stent was recaptured into the Prowler Select Plus catheter. During the recapture, there was initial resistance. This was easily overcome after deploying the stent a little more before resheathing. During the procedure, the patient received 2000 U of heparin after the first coil was detached in the aneurysm. CONCLUSION The stent remodeling technique is a novel endovascular technique that can be used to treat ruptured wide-neck aneurysms and maintain patency of parent vessels, avoiding the use of antiplatelet therapy in acute subarachnoid hemorrhage.


2002 ◽  
Vol 15 (5) ◽  
pp. 537-548 ◽  
Author(s):  
G.B. Bradač ◽  
G. Stura ◽  
M. Bergui

Balloon occlusion of parent vessel and direct coiling are the two endovascular techniques routinely used and commonly accepted as alternatives to surgery for treatment of the cerebral aneurysm in many patients. Based on our experience and what is reported in the literature, the various aspects concerning techniques, difficulties, risks, are described. In comparison to surgery, the endovascular approach is a relatively new technique, which is still in evolution. To date, there is no objective indication regarding the method to be used in a given case. The experience and attitude of the involved team still play an essential role.


1989 ◽  
Vol 71 (4) ◽  
pp. 512-519 ◽  
Author(s):  
Randall T. Higashida ◽  
Van V. Halbach ◽  
Leslie D. Cahan ◽  
Grant B. Hieshima ◽  
Yoshifumi Konishi

✓ Treatment of complex and surgically difficult intracranial aneurysms of the posterior circulation is now being performed with intravascular detachable balloon embolization techniques. The procedure is carried out under local anesthesia from a transfemoral arterial approach, which allows continuous neurological monitoring. Under fluoroscopic guidance, the balloon is propelled by blood flow through the intracranial circulation and, in most cases, can be guided directly into the aneurysm, thus preserving the parent vessel. If an aneurysm neck is not present, test occlusion of the parent vessel is performed and, if tolerated, the balloon is detached. Twenty-six aneurysms in 25 patients have been treated by this technique. The aneurysms have involved the distal vertebral artery (five cases), the mid-basilar artery (six cases), the distal basilar artery (11 cases), and the posterior cerebral artery (four cases). The aneurysms varied in size and included three small (< 12 mm), 15 large (12 to 25 mm), and eight giant (> 25 mm). Fifteen patients (60%) presented with hemorrhage and 10 patients (40%) with mass effect. In 17 cases (65%) direct balloon embolization of the aneurysm was achieved with preservation of the parent artery. In nine cases (35%), because of aneurysm location and size, occlusion of the parent vessel was performed. Complications from therapy included three cases of transient cerebral ischemia which resolved, three cases of stroke, and five deaths due to immediate or delayed aneurysm rupture. The follow-up period has ranged from 2 months to 43 months (mean 22.5 months). In cases where posterior circulation aneurysms have been difficult to treat by conventional neurosurgical techniques, intravascular detachable balloon embolization may offer an alternative therapeutic option.


Sign in / Sign up

Export Citation Format

Share Document