scholarly journals Case Report: The efficacy of early phacoemulsification in the intraocular pressure control in primary angle closure glaucoma associated with cataract in a young female

F1000Research ◽  
2020 ◽  
Vol 9 ◽  
pp. 372
Author(s):  
Carmen-Ecaterina Leferman ◽  
Madalina Cazacut ◽  
Alin Dumitru Ciubotaru

Glaucoma is a leading cause of irreversible blindness in the world, second only to cataract. Among different types of glaucoma, irreversible bilateral visual impairment is more common in primary angle closure glaucoma (PACG) patients. PACG and cataract often coexist and are both more prevalent among the elderly population, being rare in children and young adults. Here, we discuss the case of a 39-year-old Caucasian woman with unilateral PACG associated with cataract. The patient presented with a several-day history of left sided headache, decreased and blurred vision as well as pain and redness of the left eye (LE). She reported similar episodes in the previous year. Visual acuity (VA) of the LE was limited to counting fingers and intra-ocular pressure (IOP) of the LE was 42 mmHg. Anterior segment examination of the LE revealed: edematous cornea, a peripheral anterior chamber depth corresponding to Van Herick’s grade 0, mid-dilated pupil and lens opacities with visible glaukomflecken. Gonioscopic evaluation revealed iridotrabecular contact for 360º, no visible angle structures and a flat–mild convex iris contour. The digital image of the optic disc suggested only a thinning of neuro-retinal rim at the lower pole. Following treatment of the initial symptoms, phacoemulsification with intra-ocular lens implant was performed. IOP improved and no IOP-lowering medication was required. The patient was monitored for VA, IOP, field of vision changes, and optic disc evaluation every six months for 2 years and no glaucomatous change occurred. The patient also denied ocular symptoms during this period. This case supports the effectiveness of early phacoemulsification in the IOP control in patients with PACG.

F1000Research ◽  
2021 ◽  
Vol 9 ◽  
pp. 372
Author(s):  
Carmen-Ecaterina Leferman ◽  
Madalina Cazacut ◽  
Alin Dumitru Ciubotaru

Glaucoma is a leading cause of irreversible blindness worldwide. Among different types of glaucoma, irreversible bilateral visual impairment is more common in primary angle closure glaucoma (PACG) patients. PACG and cataract often coexist and are both more prevalent among the elderly population, being rare in children and young adults. Here, we discuss the case of a 39-year-old Caucasian woman with unilateral PACG associated with cataract. The patient presented with a several-day history of left sided headache, decreased and blurred vision as well as pain and redness of the left eye (LE). She reported similar episodes in the previous year. Visual acuity (VA) of the LE was limited to counting fingers and intra-ocular pressure (IOP) of the LE was 42 mmHg. Anterior segment examination of the LE revealed: edematous cornea, a peripheral anterior chamber depth corresponding to Van Herick’s grade 0, mid-dilated pupil and lens opacities with visible glaukomflecken. Gonioscopic evaluation revealed iridotrabecular contact for 360º, no visible angle structures and a flat–mild convex iris contour. Spectral domain optical coherence tomography suggested only a thinning of neuro-retinal rim at the lower pole. Following treatment of the initial symptoms, phacoemulsification with intra-ocular lens implant was performed. IOP improved and no IOP-lowering medication was required. The patient was monitored for VA, IOP, field of vision changes, and optic disc evaluation every six months for 2 years and no glaucomatous change occurred. The patient also denied ocular symptoms during this period. This case supports the effectiveness of early phacoemulsification in the IOP control in patients with PACG.


2021 ◽  
Vol 8 ◽  
Author(s):  
Haijun Gong ◽  
Xu Dong ◽  
Bingru Zheng ◽  
Xinbo Gao ◽  
Liming Chen ◽  
...  

Objective: The treatment procedures of primary angle-closure glaucoma (PACG) with extensive peripheral anterior synechia (PAS) is a subject of debate. This study is to investigate the clinical features of phacoemulsification (Phaco)-visco dissection in medically controlled PACG patients with PAS > 180° and evaluate the predictability of Ultrasound Biomicroscopy (UBM) parameters on postoperative intraocular pressure (IOP).Methods: 48 eyes (48 patients) with acute angle-closure glaucoma (AACG) and 30 eyes (30 patients) with chronic angle-closure glaucoma (CACG) were prospectively included. All patients underwent phaco-viscogoniolysis and foldable lens implantation and were followed for 1 year after surgery. We analyzed preoperative and postoperative IOP, the numbers of anti-glaucoma medicine, the visual field value, the extent of PAS, and UBM parameters alterations, and evaluated the correlation between preoperative UBM parameters and one-year postoperative IOP.Results: IOP reduced significantly from 16.24 ± 4.33 to 14.49 ± 3.69 mmHg in AACG group and from 16.16 ± 3.69 mmHg to 14.31 ± 4.12 mmHg in CACG group, and PAS decreased significantly from 270 ± 60.33 to 171 ± 56.44° in AACG group and from 285 ± 70.46 to 168 ± 61.32° in CACG group, and the number of anti-glaucoma drugs decreased significantly in both groups. Several UBM parameters, including anterior chamber depth, trabecular iris angle, and peripheral iris thickness 500 increased while iris convex reduced considerably in the two groups, and angle opening distance 500 and trabecular-meshwork ciliary process angle increased significantly only in AACG group. One-year postoperative IOP correlated with preoperative angle opening distance 500 and trabecular iris angle negatively and iris convex positively.Conclusion: Phaco-visco dissection can effectively reduce IOP, the numbers of glaucomatous medications, and PAS in medically controlled PACG patients with extensive PAS. UBM parameters might be valuable for analyzing postoperative anterior segment structure and predicting postoperative IOP of Phaco-visco dissection in PACG patients with extensive PAS.


2017 ◽  
Vol 11 (3) ◽  
pp. 86-91 ◽  

ABSTRACT Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student's t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 μm from scleral spur (AOD 500), trabecular—ciliary process distance (TCPD), iris—ciliary process distance (ICPD), and iris—zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral—iris angle (SIA), and scleral—ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris—lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yunhua Loo ◽  
Tin A. Tun ◽  
Eranga N. Vithana ◽  
Shamira A. Perera ◽  
Rahat Husain ◽  
...  

AbstractTo investigate the association of peripheral anterior synechiae (PAS) with intraocular pressure (IOP) and anterior-segment parameters in subjects with primary angle-closure glaucoma (PACG). A total of 267 subjects with PACG were recruited and underwent gonioscopy and anterior-segment optical coherence tomography (ASOCT). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750) and trabecular-iris-space-area (TISA750) at 750 µm from the scleral spur, anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Presenting IOP was defined as the first IOP reading before the initiation of IOP-lowering treatment. The mean age of the 267 subjects was 67.0 ± 8.9 years, 140 (52.4%) were male, and 246 (92.1%) were of Chinese ethnicity. PAS was present in 122 (45.7%) subjects, and was most frequently found in the superior quadrant (79.5%). Subjects with PAS had greater presenting IOP (28.7 ± 12.9 vs 22.4 ± 9.7 mmHg, p < 0.001), narrower AOD750 (p < 0.001), smaller TISA750 (p < 0.001), ACD (p = 0.04), ACA (p = 0.02), ACV (p = 0.01) and larger LV (p = 0.01) compared to PACG eyes without PAS. No significant differences were noted for iris parameters. A multivariate logistic regression analysis showed that higher presenting IOP (β = 0.20, p < 0.001), worse visual field mean deviation (β = − 0.20, p = 0.01) and narrower AOD750 (β = − 0.25, p = 0.03) were the only parameters that significantly correlated with the extent of PAS in clock hours. Almost one-half of the subjects with PACG demonstrated PAS; these eyes were associated with higher presenting IOP, smaller anterior segment dimensions and more severe disease.


PLoS Genetics ◽  
2014 ◽  
Vol 10 (3) ◽  
pp. e1004089 ◽  
Author(s):  
Monisha E. Nongpiur ◽  
Chiea Chuen Khor ◽  
Hongyan Jia ◽  
Belinda K. Cornes ◽  
Li-Jia Chen ◽  
...  

Eye ◽  
2016 ◽  
Vol 31 (4) ◽  
pp. 572-577 ◽  
Author(s):  
M E Nongpiur ◽  
E Atalay ◽  
T Gong ◽  
M Loh ◽  
H K Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document