System identification of the suspension tower of Runyang Bridge based on ambient vibration tests

2017 ◽  
Vol 19 (5) ◽  
pp. 523-538 ◽  
Author(s):  
Zhijun Li ◽  
Dongming Feng ◽  
Maria Q. Feng ◽  
Xiuli Xu
2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Sergio Vincenzo Calcina ◽  
Laura Eltrudis ◽  
Luca Piroddi ◽  
Gaetano Ranieri

This paper deals with the ambient vibration tests performed in an arch dam in two different working conditions in order to assess the effect produced by two different reservoir water levels on the structural vibration properties. The study consists of an experimental part and a numerical part. The experimental tests were carried out in two different periods of the year, at the beginning of autumn (October 2012) and at the end of winter (March 2013), respectively. The measurements were performed using a fast technique based on asynchronous records of microtremor time-series. In-contact single-station measurements were done by means of one single high resolution triaxial tromometer and two low-frequency seismometers, placed in different points of the structure. The Standard Spectral Ratio method has been used to evaluate the natural frequencies of vibration of the structure. A 3D finite element model of the arch dam-reservoir-foundation system has been developed to verify analytically determined vibration properties, such as natural frequencies and mode shapes, and their changes linked to water level with the experimental results.


1978 ◽  
Vol 104 (5) ◽  
pp. 983-999
Author(s):  
Ahmed M. Abdel-Ghaffar ◽  
George W. Housner

2018 ◽  
Vol 3 (3) ◽  
pp. 39
Author(s):  
Marcos Chávez ◽  
Fernando Peña ◽  
Claudia Cruz ◽  
Gustavo Monroy

This article presents a study on the structural behavior of the Government Building that is part of the old Lecumberri Palace and which currently houses the Mexican General Archive of the Nation. This building was inaugurated in 1900 and closed in 1976, after serving as a prison for 76 years. It was reopened in 1982 after it had undergone several remodeling works. The construction is made of brick masonry with lime mortar. It is supported by a deposit of overly compressible high-plasticity clays. The main problems of this building are the appearance of cracks in both interior and exterior walls, and moisture in the ground floor, caused by differential settlements. The study entailed a geometric and a damage survey as well as ambient vibration tests in order to determine the dynamic properties of the construction. The data obtained was used for the making of a model that, using the finite element method, was analyzed under different load conditions. This study has focused on the overall response with the assumption of smeared crack damage. According to the results, the building’s safety was deemed as acceptable. It has the capability to withstand seismic actions as established by the Mexican Building Code due to the high density of its walls and the resulting stiffness, which infer that the fundamental vibration period of the building would be distant from the predominant vibration period of the soil. This highlights the idea that the building’s critical condition is constituted by the differential settlements, which cause damage in the construction.


2010 ◽  
Vol 24 (5) ◽  
pp. 1274-1290 ◽  
Author(s):  
Filipe Magalhães ◽  
Álvaro Cunha ◽  
Elsa Caetano ◽  
Rune Brincker

Sign in / Sign up

Export Citation Format

Share Document