Development of a MEA for proton-exchange membrane type water electrolyzer using a platinum substitution nickel-CNO catalyst

2020 ◽  
Vol 2020.57 (0) ◽  
pp. 65-66
Author(s):  
Shou SOUMA ◽  
Shin’ya OBARA ◽  
Akihiko MIYAKOSHI ◽  
Fumihiro KODERA
Author(s):  
Denise A. McKay ◽  
Anna G. Stefanopoulou ◽  
Jeffrey Cook

For temperature and humidity control of proton exchange membrane fuel cell (PEMFC) reactants, a membrane based external humidification system was designed and constructed. Here we develop and validate a physics based, low-order, control-oriented model of the external humidification system dynamics based on first principles. This model structure enables the application of feedback control for thermal and humidity management of the fuel cell reactants. The humidification strategy posed here deviates from standard internal humidifiers that are relatively compact and cheap but prohibit active humidity regulation and couple reactant humidity requirements to the PEMFC cooling demands. Additionally, in developing our model, we reduced the number of sensors required for feedback control by employing a dynamic physics based estimation of the air-vapor mixture relative humidity leaving the humidification system (supplied to the PEMFC) using temperature and pressure measurements. A simple and reproducible methodology is then employed for parameterizing the humidification system model using experimental data.


2019 ◽  
Author(s):  
Valentina Guccini ◽  
Annika Carlson ◽  
Shun Yu ◽  
Göran Lindbergh ◽  
Rakel Wreland Lindström ◽  
...  

The performance of thin carboxylated cellulose nanofiber-based (CNF) membranes as proton exchange membranes in fuel cells has been measured in-situ as a function of CNF surface charge density (600 and 1550 µmol g<sup>-1</sup>), counterion (H<sup>+</sup>or Na<sup>+</sup>), membrane thickness and fuel cell relative humidity (RH 55 to 95 %). The structural evolution of the membranes as a function of RH as measured by Small Angle X-ray scattering shows that water channels are formed only above 75 % RH. The amount of absorbed water was shown to depend on the membrane surface charge and counter ions (Na<sup>+</sup>or H<sup>+</sup>). The high affinity of CNF for water and the high aspect ratio of the nanofibers, together with a well-defined and homogenous membrane structure, ensures a proton conductivity exceeding 1 mS cm<sup>-1</sup>at 30 °C between 65 and 95 % RH. This is two orders of magnitude larger than previously reported values for cellulose materials and only one order of magnitude lower than Nafion 212. Moreover, the CNF membranes are characterized by a lower hydrogen crossover than Nafion, despite being ≈ 30 % thinner. Thanks to their environmental compatibility and promising fuel cell performance the CNF membranes should be considered for new generation proton exchange membrane fuel cells.<br>


Sign in / Sign up

Export Citation Format

Share Document