scholarly journals Localization method of contact-type failure by measuring the structural intensity of low-frequency vibrations caused by frequency down-conversion of elastic vibrations

Author(s):  
Takashi TANAKA ◽  
Junnosuke ASANO ◽  
Yasunori OURA
2014 ◽  
Vol 926-930 ◽  
pp. 1857-1860
Author(s):  
Zhou Zheng ◽  
Meng Yuan Li ◽  
Wei Jiang Wang

In order to reduce the burden of the calculation and the low frequency resolution of the tradition GNSS signal intermediate narrow band anti-jamming method, it introduces a high efficient approach of narrow band interference rejection based on baseband GNSS signal processing. After digital down conversion to baseband and down sampling to a low rate, the interference is removed in frequency domain. According to the theoretical analysis and simulation, it claims that the method can reduce the calculation and increase the detection resolution in frequency domain which will realize a high efficient interference rejection.


2014 ◽  
Vol 40 (9) ◽  
pp. 854-858 ◽  
Author(s):  
S. M. Poperezhai ◽  
N. S. Bondar ◽  
V. I. Kut′ko ◽  
A. S. Kovalev

2021 ◽  
Vol 6 (1) ◽  
pp. 38
Author(s):  
Samuel Zeising ◽  
Rebecca Seidl ◽  
Angelika Thalmayer ◽  
Georg Fischer ◽  
Jens Kirchner

Wireless capsule endoscopy is a promising and less invasive alternative to conventional endoscopy. A patient swallows a small capsule with an integrated camera to capture a video of the gastrointestinal tract. For accurate diagnosis and therapy, the capsule position in terms of the travelled distance must be known for each video frame. However, to date, there is no reliable localization method for endoscopy capsules. In this paper, a novel magnetic localization method is proposed. A coil as a magnetic field source is integrated into a capsule and fed with a low-frequency alternating current to prevent static geomagnetic field interference. This alternating magnetic field is measured by twelve magnetic sensors arranged in rings around the abdomen. The coil and the capsule batteries were designed based on the geometry and power supply of a commercially available endoscopy capsule and simulated by COMSOL Multiphysics software. In this way, the coil position and orientation were determined with an accuracy below 1 mm and 1°, respectively. As an analytic model for the magnetic flux density of the coil in that setup, a modified dipole model was derived. It was used to show that the batteries help to increase the amplitude of the magnetic flux density. The model is valid when signals below 100 Hz are applied, and no eddy currents are generated within the batteries. It is concluded that the magnetic flux density generated by the developed coil would be measurable with state-of-the-art magnetic sensors.


Sign in / Sign up

Export Citation Format

Share Document