scholarly journals Mechanical thrombectomy for acute occlusion of the posterior inferior cerebellar artery: A case report

2021 ◽  
Vol 9 (10) ◽  
pp. 2268-2273
Author(s):  
Hong-Bo Zhang ◽  
Pian Wang ◽  
Yan Wang ◽  
Jiang-Hong Wang ◽  
Zheng Li ◽  
...  
2010 ◽  
Vol 19 (5) ◽  
pp. 420-424
Author(s):  
Kenta Aso ◽  
Yoshitaka Kubo ◽  
Shunsuke Kakino ◽  
Hiroshi Kashimura ◽  
Atsushi Sugawara ◽  
...  

1993 ◽  
Vol 33 (9) ◽  
pp. 634-637 ◽  
Author(s):  
Shoichiro KAWAGUCHI ◽  
Toshisuke SAKAKI ◽  
Kitaro KAMADA ◽  
Hideaki IWANAGA ◽  
Katsushige TAKEHASHI ◽  
...  

2019 ◽  
Vol 124 ◽  
pp. 110-115 ◽  
Author(s):  
Ali Tayebi Meybodi ◽  
Leandro Borba Moreira ◽  
Xiaochun Zhao ◽  
Michael T. Lawton ◽  
Mark C. Preul

2021 ◽  
Vol 12 ◽  
Author(s):  
Noriya Enomoto ◽  
Kenji Yagi ◽  
Shunji Matsubara ◽  
Masaaki Uno

Bow hunter's syndrome (BHS) is most commonly caused by compression of the vertebral artery (VA). It has not been known to occur due to an extracranially originated posterior inferior cerebellar artery (PICA), the first case of which we present herein. A 71-year-old man presented with reproducible dizziness on leftward head rotation, indicative of BHS. On radiographic examination, the bilateral VAs merged into the basilar artery, and the left VA was predominant. The right PICA originated extracranially from the right VA at the atlas–axis level and ran vertically into the spinal canal. During the head rotation that induced dizziness, the right PICA was occluded, and a VA stenosis was revealed. Occlusion of the PICA was considered to be the primary cause of the dizziness. The patient underwent surgery to decompress the right PICA and VA via a posterior cervical approach. Following surgery, the patient's dizziness disappeared, and the stenotic change at the right VA and PICA improved. The PICA could be a causative artery for BHS when it originates extracranially at the atlas–axis level, and posterior decompression is an effective way to treat it.


Author(s):  
Patrick J Grover ◽  
Lauren Harris ◽  
Ayman M Qureshi ◽  
Adam Rennie ◽  
Fergus Robertson ◽  
...  

This is the eighth case report of a pediatric dissecting posterior inferior cerebellar artery aneurysm. The authors present the case of a 13-year-old boy who presented with posttraumatic posterior fossa subdural, subarachnoid, and intraventricular hemorrhage with hydrocephalus. Initial vascular imaging findings were negative; however, a high level of suspicion is necessary. The aneurysm was identified on day 20, after recurrence of hydrocephalus, and was treated with endovascular vessel sacrifice. The patient made a good recovery. It is important to consider arterial dissection in pediatric traumatic brain injury, especially with suspicious findings on initial CT scan and clinical presentation out of proportion to the mechanism of injury. Delayed vascular imaging is imperative for appropriate management.


2020 ◽  
Vol 1 (2) ◽  
Author(s):  
Oded Goren ◽  
Raghuram Sampath ◽  
Akshal S Patel ◽  
Christoph J Griessenauer ◽  
Clemens M Schirmer ◽  
...  

ABSTRACT BACKGROUND AND IMPORTANCE The Coupler microanastomotic device (Medical Companies Alliance, Birmingham, Alabama) aims at facilitating safe and efficient end-to-end reconstruction of the native vessel ends following resection of intracranial aneurysms. CLINICAL PRESENTATION We report the first case of the Coupler device used to treat a ruptured posterior inferior cerebellar artery (PICA) aneurysm. Following aneurysmal trapping and excision, the native parent vessel ends were connected in an end-to-end fashion. CONCLUSION The microanastomotic Coupler device is an acceptable option for end-to-end anastomosis and was successfully applied in the management of a ruptured fusiform PICA aneurysm.


Sign in / Sign up

Export Citation Format

Share Document