Two-shot common-path phase-shifting interferometer with a four-step algorithm and an unknown phase shift

2014 ◽  
Vol 53 (10) ◽  
pp. 2067 ◽  
Author(s):  
Zhi Zhong ◽  
Bengong Hao ◽  
Mingguang Shan ◽  
Ying Wang ◽  
Ming Diao ◽  
...  
2020 ◽  
Vol 59 (7) ◽  
pp. 2128
Author(s):  
Luis García-Lechuga ◽  
Patricia Pérez-Luna ◽  
Victor H. Flores ◽  
Areli Montes-Pérez ◽  
Adolfo Quiroz-Rodríguez ◽  
...  

2007 ◽  
Vol 273 (1) ◽  
pp. 54-59 ◽  
Author(s):  
X.F. Xu ◽  
L.Z. Cai ◽  
Y.R. Wang ◽  
X.F. Meng ◽  
H. Zhang ◽  
...  

2014 ◽  
Vol 3 (4) ◽  
Author(s):  
David-Ignacio Serrano-García ◽  
Amalia Martinez-García ◽  
Noel-Iván Toto-Arellano ◽  
Yukitoshi Otani

AbstractAn interferometer capable of retrieving the phase information in a single shot was implemented, the system was made by taking into account the double interferogram output obtained in a Mach Zehnder interferometer and then retrieving the phase information using a two-step algorithm already encountered in the literature. By controlling the polarization properties of the system, a new polarization phase shifting technique was implemented based upon the rotation of two quarter wave retarders placed in each of the arms of the interferometer. We present the analytical model taking into account the necessary conditions presented by the demodulation method. The configuration presented does not require micro-polarizer arrays or diffraction gratings presenting the advantage of avoiding the use of conventional polarizing filters to control the phase shift. Experimental results are presented.


2020 ◽  
Author(s):  
Songsong Zhang ◽  
Haisong Huang ◽  
Qiaoqiao Xiong

Abstract Variable frequency phase shift interferometry is widely applied in optical precision measurement, with the accuracy of phase extraction’s direct impact on that of phase shift interferometry. In the variable-frequency phase-shift interferometry, the commonly used phase-shifting devices are prone to phase shift errors, because the ordinary equal-step phase extraction algorithm, which can be merely used to measure simple and smooth surface, influences the accuracy of phase extraction resulting in measuring error, and causes inefficiency led by the long time the iterative process lasts for when applied in complex stepped surfaces measurement. As a sort of step-by-step phase-shifting phase extraction algorithm based on selective sampling is used to measure the step surface contour, the interference image is firstly sampled at equal intervals to reduce the iterative calculation, and in view of the fact that the phase calibration of the test system is not required in this algorithm, the measured phase is given by using the alternating iterative method despite the unknown phase and unknown phase shift amount. The phase extraction accuracy and iteration time among traditional iterative algorithm, four-step phase shift algorithm and the variable phase shift phase interpolation algorithm based on selective sampling are compared in the simulation and experiment. It is shown that the variable frequency phase shifting interference phase extraction algorithm based on selective sampling has shorter operation time, less error and higher accuracy than traditional iterative algorithm in measuring complex step surface.


2005 ◽  
Vol 44 (8) ◽  
pp. 1401 ◽  
Author(s):  
Cho Jui Tay ◽  
Chenggen Quan ◽  
Lujie Chen

Sign in / Sign up

Export Citation Format

Share Document