Restoration of terahertz continuous wave image obtained by continuous scan mode with large time constant

2014 ◽  
Vol 53 (32) ◽  
pp. 7735 ◽  
Author(s):  
Xiao Lou ◽  
Lei Hou ◽  
Gaoyuan Guo ◽  
Wei Shi
2008 ◽  
Vol 2 (1) ◽  
pp. 28-30 ◽  
Author(s):  
Bai Xufang

Left ventricular relaxation time constant, Tau, is the best index to evaluate left ventricular diastolic function. The measurement is only available traditionally in catheter lab. In Echo lab, several methods of non-invasive measurement of Tau have been tried since 1992, however almost all the methods are still utilizing the same formula to calculate Tau as in catheter lab, which makes them inconvenient, time-consuming and sometimes not very accurate. A simple method to calculate Tau in patients with mitral regurgitation has been developed just based on Weiss’ formula and simplified Bernoulli’s equation. Similarly, formulas are developed here by pure mathematical derivative to calculate Tau by continuous-wave Doppler in patients with aortic regurgitation.


2008 ◽  
Vol 2 (1) ◽  
pp. 9-11 ◽  
Author(s):  
Xufang Bai

Left ventricular relaxation time constant, Tau, is the best index to evaluate left ventricular diastolic function, but the measurement is only available traditionally in catheter lab. In Echo lab, several methods of non-invasive measurement of Tau have been tried since 1992, however almost all the methods are still utilizing the same formula to calculate Tau as in catheter lab, which makes them inconvenient, time-consuming and sometimes not very accurate. Based on Weiss’ formula and simplified Bernoulli’s equation, a simple method is developed by pure mathematical derivative to calculate Tau by continuous-wave Doppler in patients with mitral regurgitation.


2013 ◽  
Vol 333-335 ◽  
pp. 22-26
Author(s):  
Xiao Fei Luo ◽  
Xian Xia ◽  
Kai Jun Wu

Aim at the electric power transformer with inductance is large, resistance is small, the inherent characteristics of the large time constant, a fast measurement scheme of power transformer winding DC resistance is proposed. The scheme adopts the increase the measurement circuit loop resistance mutation method, in which the circuit transition process from a time constant is forced to another time constant, to realize the rapid measurement of winding DC resistance in power transformer. Simulation results show the effectiveness of the scheme.


1971 ◽  
Vol 26 (11) ◽  
pp. 1897-1900 ◽  
Author(s):  
T. D. Märk ◽  
H. J. Oskam

Emission having a large time constant has been measured recently in the decay period of plasmas produced in nitrogen and helium-nitrogen mixtures. Whereas the fast decaying emission during the early afterglow originates from the plasma volume, it was suspected that emission responsible for the large time constant (10 to 15 ms) was not due to emission processes involving nitrogen. The present studies relate to detailed measurements of this phenomenon in a decaying helium plasma produced in a Kovarglass built discharge tube. It will be shown that this slow decaying emission is due to phosphorescence of the walls of the glass tube.


2019 ◽  
Vol 16 (3) ◽  
pp. 20181075-20181075
Author(s):  
Quan Li ◽  
Yan Li ◽  
Xiaosong Wang ◽  
Xin Liu ◽  
Yu Liu

Sign in / Sign up

Export Citation Format

Share Document