scholarly journals Rapid Quantitative Method Using Spin Columns to Measure Porphobilinogen in Urine

2008 ◽  
Vol 54 (2) ◽  
pp. 429-431 ◽  
Author(s):  
Mikhail Roshal ◽  
Jeanne Turgeon ◽  
Petrie M Rainey

Abstract Background: Large increases of urinary porphobilinogen (PBG) indicate acute porphyria, which may be due to acute intermittent porphyria, variegate porphyria, or hereditary coproporphyria. These conditions are relatively rare but share symptoms with more common conditions, such as acute surgical abdomen, and often must be ruled out rapidly. Reported quantitative methods for PBG measurement are time-consuming and inconvenient. We developed a rapid quantitative method that uses resin-packed spin columns to measure PBG in urine. Method: We applied urine to anion exchange resin in a spin column, then performed centrifugal separation and washing. PBG was eluted in 1 mol/L acetic acid and reacted with Ehrlich’s reagent. After 5 min, we measured absorbance at 525, 555, and 585 nm. PBG concentration (mg/L) was calculated as 88 (A555 − ½(A525 + A585)). Results: The reportable PBG concentration range was 0.2–15 mg/L. Between-day (total) imprecision (CV) was 8.4% at 1.2 mg/L and 3.5% at 4.4 mg/L. Comparison with our established method (x) yielded a Deming regression equation: y = 1.04x − 0.01 mg/L (R2 = 0.98; Sy,x = 0.87 mg/L). No interference was noted from urobilinogen or highly colored urine specimens. Conclusions: This method for PBG measurement is more rapid and precise than other methods. This test can serve as a quick screening test and facilitates batch analysis for routine quantitative testing.

1961 ◽  
Vol 7 (2) ◽  
pp. 165-174 ◽  
Author(s):  
Gordon C Mills

Abstract Procedures are described that utilize an anion exchange resin for preliminary purification of porphyrins from highly colored urine specimens. Following purification, porphyrins may be quantitatively determined by a spectrophotometric method. A procedure is outlined for routine screening of porphyrins in the urines of hospital patients.


1971 ◽  
Vol 17 (3) ◽  
pp. 199-205 ◽  
Author(s):  
Carolyn A Martinez ◽  
Gordon C Mills

Abstract A rapid procedure has been developed in which an anion-exchange resin and spectrophotofluorometry are used to determine total porphyrins in urine. After porphyrins are eluted from the resin with 3N HCl, their fluorescence at 646 nm is measured with an Aminco-Bowman Spectrophotofluorometer. About 10 min are required per analysis by a skilled technician. Added to urine specimens, 95.3 ± 4.9% of uroporphyrin and 94.7 ± 9.6% of coproporphyrin, were accounted for. Eighteen normal urine samples contained an average of 0.063 µmol of porphyrin per liter (range, 0.028-0.176 µmol/liter). The coefficient of variation, 2.9%, indicates the precision to be very satisfactory.


2015 ◽  
Vol 5 (1) ◽  
pp. 11
Author(s):  
Anies Mutiari ◽  
Wiratni Wiratni ◽  
Aswati Mindaryani

Pemurnian biogas telah banyak dilakukan untuk menghilangkan kadar CO2  dan meningkatkan kandungan CH4  yang terkandung di dalamnya. Kandungan CH4 yang tinggi akan memberikan unjuk kerja yang lebih baik. Model  matematis proses adsorpsi CO2 disusun berdasarkan teori lapisan film antar fasa, dimana pada proses yang ditinjau terdapat tiga fase yaitu gas, cair dan padat. Model matematis dari data eksperimental   kecepatan dan kesetimbangan proses adsorpsi CO2 melalui mekanisme pertukaran ion di suatu kolom adsorpsi telah dibuat. Model ini dibuat untuk mencari konstanta yang dapat dipergunakan pada proses scale up data laboratorium ke skala pilot plant. Parameter proses kecepatan yang dicari nilainya adalah koefisien transfer massa massa volumetris CO2 pada fase cair (kLa), koefisien transfer massa volumetris CO2 pada fasegas (kGa) dan tetapan laju reaksi (k1 dan k2). Pada hasil penelitian ini ditunjukkan bahwa nilai parameter yang diperoleh sesuai hasil fitting data dengan model matematis yang digunakan, yaitu model transfer massa pada lapisan film antar fase secara seri: adalah kGa, kla, k1 dan k2  dengan nilai Sum of Squares Error (SSE) rata-rata 0,0431. Perbandingan nilai kGa hasil simulasi dan teoritisnya memberikan kesalahan rata-rata 18,79%. Perbandingan nilai kLa hasil simulasi dan teoritis memberikan kesalahan rata-rata 7,92%.Kata kunci: model matematis, adsorpsi CO2, pemurnian biogas


2013 ◽  
Vol 2 (2) ◽  
pp. 79-87 ◽  
Author(s):  
Laura A. Pena ◽  
Alissa M. Chan ◽  
Larissa R. Cohen ◽  
Karen Hou ◽  
Brent M. Harvey ◽  
...  

2021 ◽  
pp. 117244
Author(s):  
Treavor H. Boyer ◽  
Yida Fang ◽  
Anderson Ellis ◽  
Rebecca Dietz ◽  
Youn Jeong Choi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document