scholarly journals Commutability Assessment of External Quality Assessment Materials with the Difference in Bias Approach: Are Acceptance Criteria Based on Medical Requirements too Strict?

2016 ◽  
Vol 62 (12) ◽  
pp. 1670-1671 ◽  
Author(s):  
Vincent Delatour ◽  
Qinde Liu ◽  
Hubert W Vesper
2018 ◽  
Vol 64 (3) ◽  
pp. 455-464 ◽  
Author(s):  
Göran Nilsson ◽  
Jeffrey R Budd ◽  
Neil Greenberg ◽  
Vincent Delatour ◽  
Robert Rej ◽  
...  

Abstract A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.


Bioanalysis ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 1743-1750
Author(s):  
Yaxin Fan ◽  
Yu Wang ◽  
Mengting Chen ◽  
Yuancheng Chen ◽  
Beining Guo ◽  
...  

Aim: To compare the difference between the measured and target values in vancomycin external quality assessment (EQA) samples and to investigate the factors for underestimating its concentration. Materials & methods: A retrospective analysis of 195 international vancomycin EQA results was performed. Deviations of the concentrations determined by TDx fluorescence polarization immunoassay (FPIA), Axsym FPIA and Architect chemiluminescence microparticle immunoassay (CMIA) method were -2.43, -16.28 and -10.53%, respectively. Chromatographic peaks of the crystalling degradation products appeared in samples with large deviations. Vancomycin were degraded after long-term transporting and high temperature. Conclusion: Vancomycin concentrations measured by Axsym FPIA and Architect CMIA methods were likely to be underestimated. Long-term transporting resulted in low EQA results, suggesting that establishing a local EQA system for vancomycin is essential.


Author(s):  
Christoph Buchta ◽  
Jeremy V. Camp ◽  
Jovana Jovanovic ◽  
Peter Chiba ◽  
Elisabeth Puchhammer-Stöckl ◽  
...  

Abstract Objectives External quality assessment (EQA) schemes provide information on individual and general analytical performance of participating laboratories and test systems. The aim of this study was to investigate the use and performance of SARS-CoV-2 virus genome detection systems in Austrian laboratories and their preparedness to face challenges associated with the pandemic. Methods Seven samples were selected to evaluate performance and estimate variability of reported results. Notably, a dilution series was included in the panel as a measure of reproducibility and sensitivity. Several performance criteria were evaluated for individual participants as well as in the cohort of all participants. Results A total of 109 laboratories participated and used 134 platforms, including 67 different combinations of extraction and PCR platforms and corresponding reagents. There were no false positives and 10 (1.2%) false negative results, including nine in the weakly positive sample (C t ∼35.9, ∼640 copies/mL). Twenty (22%) laboratories reported results of mutation detection. Twenty-five (19%) test systems included amplification of human RNA as evidence of proper sampling. The overall linearity of C t values from individual test systems for the dilution series was good, but inter-assay variability was high. Both operator-related and systematic failures appear to have caused incorrect results. Conclusions Beyond providing certification for participating laboratories, EQA provides the opportunity for participants to evaluate their performance against others so that they may improve operating procedures and test systems. Well-selected EQA samples offer additional inferences to be made about assay sensitivity and reproducibility, which have practical applications.