dilution series
Recently Published Documents


TOTAL DOCUMENTS

76
(FIVE YEARS 18)

H-INDEX

13
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Addgene The Nonprofit Plasmid Repository

This protocol describes ddPCR titration of AAV vectors. To see the full abstract and additional resources, visit https://www.addgene.org/protocols/aav-ddpcr-titration/. Sample Data: When analyzing data there should be a clear distinction between negative droplets (black) and positive droplets (blue). The no template control (NTC) should be close to zero (B08). At Addgene, runs with an NTC >5 are invalid. To reduce NTC values, we recommend wiping down all pipettes and equipment with 10% bleach prior to use and keeping all reagents and samples on ice or pre-chilled 96-well freezer blocks during use. In this protocol, a dilution series is prepared for each AAV sample and the 3 final dilutions are assayed. The samples that are assayed are diluted 2-fold serially therefore, the concentration obtained by ddPCR should decrease by a factor of 2 across the dilutions. In the example below, 2-fold serial dilutions of a sample were loaded in wells A04, A05 and A06. As shown in the image and table below, the concentration of positive droplets decreases by a factor of ~2. To increase the accuracy of the titer, calculate an average of several dilutions. For additional tips on AAV titering using ddPCR, read our blog post.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Amelia E. Sancilio ◽  
Richard T. D’Aquila ◽  
Elizabeth M. McNally ◽  
Matthew P. Velez ◽  
Michael G. Ison ◽  
...  

AbstractThe spike protein of SARS-CoV-2 engages the human angiotensin-converting enzyme 2 (ACE2) receptor to enter host cells, and neutralizing antibodies are effective at blocking this interaction to prevent infection. Widespread application of this important marker of protective immunity is limited by logistical and technical challenges associated with live virus methods and venous blood collection. To address this gap, we validated an immunoassay-based method for quantifying neutralization of the spike-ACE2 interaction in a single drop of capillary whole blood, collected on filter paper as a dried blood spot (DBS) sample. Samples are eluted overnight and incubated in the presence of spike antigen and ACE2 in a 96-well solid phase plate. Competitive immunoassay with electrochemiluminescent label is used to quantify neutralizing activity. The following measures of assay performance were evaluated: dilution series of confirmed positive and negative samples, agreement with results from matched DBS-serum samples, analysis of results from DBS samples with known COVID-19 status, and precision (intra-assay percent coefficient of variation; %CV) and reliability (inter-assay; %CV). Dilution series produced the expected pattern of dose–response. Agreement between results from serum and DBS samples was high, with concordance correlation = 0.991. Analysis of three control samples across the measurement range indicated acceptable levels of precision and reliability. Median % surrogate neutralization was 46.9 for PCR confirmed convalescent COVID-19 samples and 0.1 for negative samples. Large-scale testing is important for quantifying neutralizing antibodies that can provide protection against COVID-19 in order to estimate the level of immunity in the general population. DBS provides a minimally-invasive, low cost alternative to venous blood collection, and this scalable immunoassay-based method for quantifying inhibition of the spike-ACE2 interaction can be used as a surrogate for virus-based assays to expand testing across a wide range of settings and populations.


PLoS ONE ◽  
2021 ◽  
Vol 16 (7) ◽  
pp. e0254356
Author(s):  
Bettina Thalinger ◽  
Yannick Pütz ◽  
Michael Traugott

The use of sensitive methods is key for the detection of target taxa from trace amounts of environmental DNA (eDNA) in a sample. In this context, digital PCR (dPCR) enables direct quantification and is commonly perceived as more sensitive than endpoint PCR. However, endpoint PCR coupled with capillary electrophoresis (celPCR) potentially embodies a viable alternative as it quantitatively measures signal strength after PCR in Relative Fluorescence Units (RFU). Provided comparable levels of sensitivity are reached, celPCR permits the development of cost-efficient multiplex reactions, enabling the simultaneous detection of several target taxa. Here, we compared the sensitivity of singleplex and multiplex celPCR to dPCR for species-specific primer pairs amplifying mitochondrial DNA (COI) of fish species occurring in European freshwaters by analyzing dilution series of tissue extracts as well as field-collected water samples. Both singleplex and multiplex celPCR and dPCR displayed comparable sensitivity with reliable positive amplifications starting at two to 10 target DNA copies per μl extract. celPCR was suitable for quantifying target DNA and direct inference of copy numbers from RFU was possible after accounting for primer effects in linear mixed-effects models and calibration via dPCR. Furthermore, multiplex celPCR and dPCR were successfully used for the detection and quantification of fish-eDNA in field-collected water samples, confirming the results of the dilution series experiment and exemplifying the high sensitivity of the two approaches. The possibility of detection and quantification via multiplex celPCR is appealing for the cost-efficient screening of high sample numbers. The present results confirm the sensitivity of this approach thus enabling its application for future eDNA-based monitoring efforts.


2021 ◽  
Vol 26 (27) ◽  
Author(s):  
Dung Nguyen ◽  
Peter Simmonds ◽  
Maurice Steenhuis ◽  
Elise Wouters ◽  
Daniel Desmecht ◽  
...  

We compared the performance of SARS-CoV-2 neutralising antibody testing between 12 European laboratories involved in convalescent plasma trials. Raw titres differed almost 100-fold differences between laboratories when blind-testing 15 plasma samples. Calibration of titres in relation to the reference reagent and standard curve obtained by testing a dilution series reduced the inter-laboratory variability ca 10-fold. The harmonisation of neutralising antibody quantification is a vital step towards determining the protective and therapeutic levels of neutralising antibodies.


Author(s):  
Christoph Buchta ◽  
Jeremy V. Camp ◽  
Jovana Jovanovic ◽  
Peter Chiba ◽  
Elisabeth Puchhammer-Stöckl ◽  
...  

Abstract Objectives External quality assessment (EQA) schemes provide information on individual and general analytical performance of participating laboratories and test systems. The aim of this study was to investigate the use and performance of SARS-CoV-2 virus genome detection systems in Austrian laboratories and their preparedness to face challenges associated with the pandemic. Methods Seven samples were selected to evaluate performance and estimate variability of reported results. Notably, a dilution series was included in the panel as a measure of reproducibility and sensitivity. Several performance criteria were evaluated for individual participants as well as in the cohort of all participants. Results A total of 109 laboratories participated and used 134 platforms, including 67 different combinations of extraction and PCR platforms and corresponding reagents. There were no false positives and 10 (1.2%) false negative results, including nine in the weakly positive sample (C t ∼35.9, ∼640 copies/mL). Twenty (22%) laboratories reported results of mutation detection. Twenty-five (19%) test systems included amplification of human RNA as evidence of proper sampling. The overall linearity of C t values from individual test systems for the dilution series was good, but inter-assay variability was high. Both operator-related and systematic failures appear to have caused incorrect results. Conclusions Beyond providing certification for participating laboratories, EQA provides the opportunity for participants to evaluate their performance against others so that they may improve operating procedures and test systems. Well-selected EQA samples offer additional inferences to be made about assay sensitivity and reproducibility, which have practical applications.


2021 ◽  
Author(s):  
Brigitta Derendinger ◽  
Margaretha de Vos ◽  
Samantha Pillay ◽  
Rouxjeane Venter ◽  
John Metcalfe ◽  
...  

Strengthening the detection of second-line drug-resistance is a key tuberculosis (TB) control priority. The performance of MTBDRplus, a multidrug-resistant (MDR)-TB assay is reduced when suboptimal ramp rates are used. We investigated ramp rate's effect on MTBDRsl; the most widely-used molecular second-line drug-resistant TB assay. We tested 52 smear-negative Xpert MTB/RIF Ultra-positive sputa and a Mycobacterium tuberculosis (Mtb) dilution series at manufacturer recommended (2.2 ° C/s) or most common suboptimal ramp rate (4.0 ° C/s; identified via an earlier survey). Mtb-complex DNA (TUB-band)-positivity, indeterminate rates, fluoroquinolone- and second-line injectable-resistance accuracy, banding differences and, separately, inter-reader variability were assessed. 39% of re-surveyed laboratories (5/13) did not use the manufacturer-recommended MTBDRsl ramp rate. On sputum, this ramp rate improved indeterminates vs. 4.0 ° C/s (0/52 vs. 7/51; p=0.006), false drug-resistance calls (0/104 vs. 6/102; p=0.013), and incorrect banding calls (0/1300 vs. 55/1275; p<0.001). Valid results (neither TUB negative, indeterminate, nor any false drug-resistance calls) (52/52 vs. 41/51; p=0.001) on sputa hence improved by +21% (95% CI: 8-34%) with optimal ramp rate usage. Suboptimal ramp rate increased banding call inter-reader variability [52/1300 (4%) vs. 34/1300 (3%); p=0.030] on sputa but not dilution series; highlighting the importance of using clinical specimens for assay performance evaluations. Suboptimal ramp rate contributes to poor MTBDRsl performance. Ramp rate correction will improve second line drug-resistant TB diagnoses. Laboratories must ensure the optimal manufacturer-recommended ramp rate is used.


F1000Research ◽  
2021 ◽  
Vol 10 ◽  
pp. 373
Author(s):  
Susan E. Manzoor ◽  
Shafquat Zaman ◽  
Celina Whalley ◽  
David Inglis ◽  
Andrew Bosworth ◽  
...  

Background: Faecal transplantation is an evidence-based treatment for Clostridioides difficile. Patients infected with SARS-CoV-2 have been shown to shed the virus in stool for up to 33 days, well beyond the average clearance time for upper respiratory tract shedding. We carried out an analytical and clinical validation of reverse-transcriptase quantitative (RT-qPCR) as well as LAMP, LamPORE and droplet digital PCR in the detection of SARS-CoV-2 RNA in stool from donated samples for faecal microbiota transplantation (FMT), spiked samples and asymptomatic inpatients in an acute surgical unit.  Methods: Killed SARS-CoV-2 viral lysate and extracted RNA was spiked into donor stool & FMT and a linear dilution series from 10-1 to 10-5 and tested via RT-qPCR, LAMP, LamPORE and ddPCR against SARS-CoV-2. Patients admitted to the critical care unit with symptomatic SARS-CoV-2 and sequential asymptomatic patients from acute presentation to an acute surgical unit were also tested. Results: In a linear dilution series, detection of the lowest dilution series was found to be 8 copies per microlitre of sample. Spiked lysate samples down to 10-2 dilution were detected in FMT samples using RTQPCR, LamPORE and ddPCR and down to 10-1 with LAMP. In symptomatic patients 5/12 had detectable SARS-CoV-2 in stool via RT-qPCR and 6/12 via LamPORE, and in 1/97 asymptomatic patients via RT-qPCR. Conclusion: RT-qPCR can be detected in FMT donor samples using RT-qPCR, LamPORE and ddPCR to low levels using validated pathways. As previously demonstrated, nearly half of symptomatic and less than one percent of asymptomatic patients had detectable SARS-CoV-2 in stool.


2021 ◽  
Author(s):  
Amelia Sancilio ◽  
Richard D’Aquila ◽  
Elizabeth M. McNally ◽  
Matt E Velez ◽  
Michael G. Ison ◽  
...  

ABSTRACTBackgroundThe spike protein of SARS-CoV-2 engages the human angiotensin-converting enzyme 2 (ACE2) receptor to enter host cells, and neutralizing antibodies are effective at blocking this interaction to prevent infection. Widespread application of this important marker of protective immunity is limited by logistical and technical challenges associated with live virus methods and venous blood collection. To address this gap, we validated an immunoassay-based method for quantifying neutralization of the spike-ACE2 interaction in a single drop of capillary whole blood, collected on filter paper as a dried blood spot (DBS) sample.MethodsSamples are eluted overnight and incubated in the presence of spike antigen and ACE2 in a 96-well solid phase plate. Competitive immunoassay with electrochemiluminescent label is used to quantify neutralizing activity. The following measures of assay performance were evaluated: dilution series of confirmed positive and negative samples, agreement with results from matched DBS-serum samples, analysis of results from DBS samples with known COVID-19 status, and precision (intra-assay percent coefficient of variation; %CV) and reliability (inter-assay; %CV).ResultsDilution series produced the expected pattern of dose-response. Agreement between results from serum and DBS samples was high, with concordance correlation = 0.991. Analysis of three control samples across the measurement range indicated acceptable levels of precision and reliability. Median % neutralization was 46.9 for PCR confirmed convalescent COVID-19 samples and 0.1 for negative samples.ConclusionsLarge-scale testing is important for quantifying neutralizing antibodies that can provide protection against COVID-19 in order to estimate the level of immunity in the general population. DBS provides a minimally-invasive, low cost alternative to venous blood collection, and this scalable immunoassay-based method for quantifying neutralization of the spike-ACE2 interaction can be used as a surrogate for virus-based assays to expand testing across a wide range of settings and populations.


2021 ◽  
Author(s):  
Susan E Manzoor ◽  
Shafquat Zaman ◽  
Celina Whalley ◽  
David Inglis ◽  
Andrew Bosworth ◽  
...  

ABSTRACTIntroductionFaecal transplantation is an evidence based treatment for Clostridiodes difficile. Patients infected with SARS-CoV-2 have been shown to shed the virus in stool for up to 33 days, well beyond the average clearance time for upper respiratory tract shedding. We carried out an analytical and clinical validation of reverse-transcriptase quantitative (RT-qPCR) as well as LAMP, LamPORE and droplet digital PCR in the detection of SARS-CoV-2 RNA in stool from donated samples for FMT, spiked samples and asymptomatic inpatients in an acute surgical unit.MethodsKilled SARS-CoV-2 viral lysate and extracted RNA was spiked into donor stool & FMT and a linear dilution series from 10−1 to 10−5 and tested via RT-qPCR, LAMP, LamPORE and ddPCR against SARS-CoV-2. Patients admitted to the critical care unit with symptomatic SARS-CoV-2 and sequential asymptomatic patients from acute presentation to an acute surgical unit were also tested.ResultsIn a linear dilution series, detection of the lowest dilution series was found to be 8 copies per microlitre of sample. Spiked lysate samples down to 10−2 dilution were detected in FMT samples using RTQPCR, LamPORE and ddPCR and down to 10−1 with LAMP. In symptomatic patients 5/12 had detectable SARS-CoV-2 in stool via RT-qPCR and 6/12 via LamPORE, and in 1/97 asymptomatic patients via RT-qPCR.ConclusionsRT-qPCR can be detected in FMT donor samples using RT-qPCR, LamPORE and ddPCR to low levels using validated pathways. As previously demonstrated, nearly half of symptomatic and less than one percent of asymptomatic patients had detectable SARS-CoV-2 in stool.


Author(s):  
Bettina Thalinger ◽  
Yannick Pütz ◽  
Michael Traugott

AbstractThe use of sensitive methods is key for the detection of target taxa, from trace amounts of environmental DNA (eDNA) in a sample. In this context, digital PCR (dPCR) enables direct quantification and is commonly perceived as more sensitive than endpoint PCR. However, endpoint PCR coupled with capillary electrophoresis (celPCR) potentially embodies a viable alternative as it quantitatively measures signal strength in Relative Fluorescence Units (RFU). Provided comparable levels of sensitivity are reached, celPCR permits the development of cost-efficient multiplex PCRs, enabling the simultaneous detection of several target taxa.Here, we compared the sensitivity of singleplex and multiplex celPCR to dPCR for species-specific primer pairs amplifying mitochondrial DNA (COI) of fish species occurring in European freshwaters by analysing dilution series of DNA extracts and field-collected water samples. Both singleplex and multiplex celPCR and dPCR displayed comparable sensitivity with reliable positive amplifications starting at two to 10 target DNA copies per µl DNA extract. celPCR was suitable for quantifying target DNA and direct inference of DNA concentrations from RFU was possible after accounting for primer effects. Furthermore, multiplex celPCRs and dPCRs were successfully used for the detection and quantification of fish-eDNA in field-collected water samples, confirming the results of the dilution series experiment and exemplifying the high sensitivity of the two approaches.The possibility of detection and quantification via multiplex celPCR is appealing for the cost-efficient screening of high sample numbers. The present results confirm the sensitivity of this approach thus enabling its application for future eDNA-based monitoring efforts.


Sign in / Sign up

Export Citation Format

Share Document