scholarly journals Sustained Use of the Impella 5.0 Heart Pump Enables Bridge to Clinical Decisions in 34 Patients

2021 ◽  
Vol 48 (3) ◽  
Author(s):  
Daniel W. Nelson ◽  
Sakthi Sundararajan ◽  
Evan Klein ◽  
Lyle D. Joyce ◽  
Lucian A. Durham ◽  
...  

We studied whether sustained hemodynamic support (>7 d) with the Impella 5.0 heart pump can be used as a bridge to clinical decisions in patients who present with cardiogenic shock, and whether such support can improve their outcomes. We retrospectively reviewed cases of patients who had Impella 5.0 support at our hospital from August 2017 through May 2019. Thirty-four patients (23 with cardiogenic shock and 11 with severely decompensated heart failure) underwent sustained support for a mean duration of 11.7 ± 9.3 days (range, ≤48 d). Of 29 patients (85.3%) who survived to next therapy, 15 were weaned from the Impella, 8 underwent durable left ventricular assist device placement, 4 were escalated to venoarterial extracorporeal membrane oxygenation support, and 2 underwent heart transplantation. The 30-day survival rate was 76.5% (26 of 34 patients). Only 2 patients had a major adverse event: one each had an ischemic stroke and flail mitral leaflet. None of the devices malfunctioned. Sustained hemodynamic support with the Impella 5.0 not only improved outcomes in patients who presented with cardiogenic shock, but also provided time for multidisciplinary evaluation of potential cardiac recovery, or the need for durable left ventricular assist device implantation or heart transplantation. Our study shows the value of using the Impella 5.0 as a bridge to clinical decisions.

2020 ◽  
Vol 36 (S2) ◽  
pp. 265-274
Author(s):  
Vipin Mehta ◽  
Rajamiyer V. Venkateswaran

Abstract Purpose Prognosis of patients presenting with INTERMACS 1 critical cardiogenic shock is generally poor. The aim of our study was to investigate the results of CentriMag™ extracorporeal short-term mechanical circulatory support as a bridge to decision in patients presenting with critical cardiogenic shock in our unit. Methods We retrospectively analysed 63 consecutive patients from January 2005 to June 2017, who were treated with a CentriMag™ device at our institution as a bridge to decision. Patients requiring extracorporeal support for post-cardiotomy shock and for primary graft dysfunction after heart transplantation were excluded. Results Patients’ median age was 44 years (IQR 31–52, range 15.4–62.0) and 42 (67%) were male. Primary diagnosis at presentation was ischaemic cardiomyopathy (n = 24; 38.1%), viral myocarditis (n = 19; 30.2%), idiopathic dilated cardiomyopathy (n = 8; 12.7%), and others (n = 12; 19%). The median duration of support was 25 (IQR 9.5–56) days. A total of 7 (11%) patients were supported with peripheral veno-arterial (VA) extra corporeal membrane oxygenation (ECMO), 6 (9%) with central VA ECMO, 8 (13%) with left ventricular assist device (LVAD), 17 (27%) with biventricular assist device (BiVAD), and 25 (40%) with ECMO and then converted to BiVAD. Overall, 22 (34.9%) patients died while on CentriMag™ mechanical circulatory support. Complications included bleeding requiring reoperation/intervention in 24 (38%), renal failure requiring dialysis in 29 (46%), bacterial infections in 23 (37%), fungal infections in 15 (24%), critical limb ischaemia in 6 (10%), and stroke in 8 (13%). The overall survival to successful explant from CentriMag™ was 65.1% (n = 41) and survival to hospital discharge was 58.7% (n = 37). Of these, 10 (16%) had cardiac recovery and were successfully explanted, 20 (32%) were bridged to heart transplantation, 11 (17%) were bridged to long-term left ventricular assist device, 3 (4.7%) were later on transplanted, and 1 (1.6%) recovered to decommissioning. The 1-, 5-, and 10-year survival rates were 55%, 46%, and 23% respectively. Conclusion Our results demonstrate an excellent outcome with the use of the CentriMag™ device in this seriously ill population. Despite requiring multiple procedures, over 58% of patients were discharged from hospital with 5-year survival of 46%.


Sign in / Sign up

Export Citation Format

Share Document