scholarly journals Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

2018 ◽  
Vol 26 (03) ◽  
pp. 1830001 ◽  
Author(s):  
Nares Chimres ◽  
Somchai Wongwises

The performance of heat exchangers impacts industry investment, energy consumption, and pollution because the heat exchanger has been used in many industries. The use of vortex generators on the fin is the prominent method of heat transfer enhancement because the performance indexes of fins with vortex generators are greater than those of the fins without vortex generators. However, this method faces obstacles because the concepts and design instructions are still obscure. Therefore, this paper provides a summary of the publications about the use of vortex generators. The publications on the effects of traditional and alternative vortex generators that are combined with plain, wavy, and louver fins are summarized. The aim of this paper is to aggregate the publications concerned with the thermal performance and flow characteristics of the fin-and-tube heat exchanger with vortex generator using numerical and experimental investigations as the guideline for future studies.


2017 ◽  
Vol 79 (7-3) ◽  
Author(s):  
Mohd Fahmi Md Salleh ◽  
Mazlan Abdul Wahid ◽  
Seyed Alireza Ghazanfari

Heat transfer enhancement is believed can be achieved by using vortex generator. In the past decades, many researches have been performed to investigate the effect of various vortex generator geometry and parameters including vortex generator angle of attack and height. However, less study has been conducted to investigate the influence of vortex generator length at different arrangement towards the heat transfer performance across the fin-and-tube heat exchanger (FTHE). Therefore, the effects of different strategy on the rectangular winglet vortex generator (RWVG) base length towards the thermal hydraulic performance across the FTHE were numerically investigated in this study. Two types of RWVG arrangement known as common flow down (CFD) or common flow up (CFU) arrangement were used and placed behind four rows of tube in inline arrangement. Total of 7 cases were investigated including the default RWVG, extended front and extended back for both RWVG in CFD and CFU arrangement together with FTHE without vortex generator which was set as the baseline case. The Reynolds number ranged from 500 to 900. It was found that the size of the wake region behind the RWVG contributed to the additional pressure drop penalty across the FTHE. Meanwhile, different thermal characteristics were found for different base length strategy in CFD and CFU arrangement. For RWVG arranged in CFD and CFU arrangement, the extended back case shows the highest heat transfer enhancement with 5 – 25 % and 5 – 15 % increment compared to the baseline case respectively. Based on JF factor evaluation, default RWVG in CFU arrangement provide better heat transfer enhancement than the pressure drop penalty compared to other RWVG cases with average JF factor value is 0.8. Nonetheless, none of the tested cases shows higher JF factor value than the baseline case.  


2009 ◽  
Vol 16 (4) ◽  
pp. 315-329 ◽  
Author(s):  
M. Mustafa Akbari ◽  
Dr. Akira Murata ◽  
Dr. Sadanari Mochizuki ◽  
H. Saito ◽  
K. Iwamoto

Sign in / Sign up

Export Citation Format

Share Document