Estimation of trueness of measurement results obtained in external quality assessment

Author(s):  
Bedrich Friedecky ◽  
Josef Kratochvila ◽  
Marek Budina
2015 ◽  
Vol 30 (1) ◽  
pp. 148-153 ◽  
Author(s):  
Marina Patriarca ◽  
Cas Weykamp ◽  
Josiane Arnaud ◽  
Robert L. Jones ◽  
Patrick J. Parsons ◽  
...  

International standards for the recognition of the competence of testing laboratories require that measurement results should be traceable to a conventionally agreed reference.


2018 ◽  
Vol 56 (5) ◽  
pp. 789-795 ◽  
Author(s):  
Jie Zeng ◽  
Tianqi Qi ◽  
Shu Wang ◽  
Tianjiao Zhang ◽  
Weiyan Zhou ◽  
...  

AbstractBackground:The aim of the current study was to evaluate the commutability of commercial control materials and human serum pools and to investigate the suitability of the materials for the external quality assessment (EQA) of serum apolipoprotein A-I (apo A-I) measurement.Methods:The Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol was used for the commutability study. Apo A-I concentrations in two levels of commercial control materials used in EQA program, two fresh-frozen human serum pools (FSPs) and two frozen human serum pools prepared from residual clinical specimens (RSPs) were measured along with 50 individual samples using nine commercial assays. Measurement results of the 50 individual samples obtained with different assays were pairwise analyzed by Deming regression, and 95% prediction intervals (PIs) were calculated. The commutability of the processed materials was evaluated by comparing the measurement results of the materials with the limits of the PIs.Results:The FSP-1 was commutable for all the 36 assay pairs, and FSP-2 was commutable for 30 pairs; RSP-1 and RSP-2 showed commutability for 27/36 and 22/36 assay pairs, respectively, whereas the two EQA materials were commutable only for 4/36 and 5/36 assay pairs, respectively.Conclusions:Non-commutability of the tested EQA materials has been observed among current apo A-I assays. EQA programs need either to take into account the commutability-related biases in the interpretation of the EQA results or to use more commutable materials. Frozen human serum pools were commutable for most of the assays.


2013 ◽  
Vol 59 (9) ◽  
pp. 1322-1329 ◽  
Author(s):  
Ingrid Zegers ◽  
Robert Beetham ◽  
Thomas Keller ◽  
Joanna Sheldon ◽  
David Bullock ◽  
...  

BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability study with 30 serum samples and the reference materials ERM-DA470, ERM-DA470k/IFCC, and ERM-DA472/IFCC, using 6 different methods. Data were analyzed according to the CLSI Guideline C53-A to assess whether the reference materials had the same behavior as the serum samples with respect to measurement results obtained with combinations of the methods used. RESULTS Measurement results from different methods showed a good linear correlation for the serum samples. ERM-DA470 showed marked noncommutability for certain combinations of methods. ERM-DA470k/IFCC and ERM-DA472/IFCC were commutable for more combinations of methods. The lack of commutability of ERM-DA470 for certain combinations of methods correlates with results from the UK National External Quality Assessment Service showing discrepancies between results from these methods. For serum stored in the presence of sodium azide the results from different methods are essentially equivalent. CONCLUSIONS Ceruloplasmin in ERM-DA470 is a fully documented example of a situation in which, due to lack of commutability, the use of a common material for calibration did not lead to harmonization .


Author(s):  
Christoph Buchta ◽  
Jeremy V. Camp ◽  
Jovana Jovanovic ◽  
Peter Chiba ◽  
Elisabeth Puchhammer-Stöckl ◽  
...  

Abstract Objectives External quality assessment (EQA) schemes provide information on individual and general analytical performance of participating laboratories and test systems. The aim of this study was to investigate the use and performance of SARS-CoV-2 virus genome detection systems in Austrian laboratories and their preparedness to face challenges associated with the pandemic. Methods Seven samples were selected to evaluate performance and estimate variability of reported results. Notably, a dilution series was included in the panel as a measure of reproducibility and sensitivity. Several performance criteria were evaluated for individual participants as well as in the cohort of all participants. Results A total of 109 laboratories participated and used 134 platforms, including 67 different combinations of extraction and PCR platforms and corresponding reagents. There were no false positives and 10 (1.2%) false negative results, including nine in the weakly positive sample (C t ∼35.9, ∼640 copies/mL). Twenty (22%) laboratories reported results of mutation detection. Twenty-five (19%) test systems included amplification of human RNA as evidence of proper sampling. The overall linearity of C t values from individual test systems for the dilution series was good, but inter-assay variability was high. Both operator-related and systematic failures appear to have caused incorrect results. Conclusions Beyond providing certification for participating laboratories, EQA provides the opportunity for participants to evaluate their performance against others so that they may improve operating procedures and test systems. Well-selected EQA samples offer additional inferences to be made about assay sensitivity and reproducibility, which have practical applications.


2021 ◽  
Vol 87 ◽  
pp. 39-45
Author(s):  
Xilian Yi ◽  
Yufei Wang ◽  
Tianjiao Zhang ◽  
Jie Zeng ◽  
Haijian Zhao ◽  
...  

2003 ◽  
Vol 333 (2) ◽  
pp. 221-230 ◽  
Author(s):  
Sandra Secchiero ◽  
Laura Sciacovelli ◽  
Lorena Zardo ◽  
Mario Plebani