A New Phase Advanced Multiloop Control System For Dynamic Voltage Restorer

ENERGYO ◽  
2018 ◽  
Author(s):  
Mohammad Ali Taghikhani ◽  
Ahad Kazemi
Author(s):  
Mohammad Ali Taghikhani ◽  
Ahad Kazemi

A dynamic voltage restorer is a power quality (custom power) device used to correct the voltage disturbances by injecting voltage as well as power into the system. The compensation capability of a dynamic voltage restorer (DVR) depends primarily on the maximum voltage injection ability and the amount of stored energy available within the restorer. In this paper a new phase advance compensation (PAC) strategy for the DVR is proposed in order to enhance the voltage restoration property of the device. Also a method of determining the exact amount of voltage injection required to systematically correct a specific voltage drop with minimum active power injection is proposed. Using the proposed method it can be shown that a particular disturbance can be corrected with less amount of storage energy compared to that of existing in-phase boosting method. Analytical expressions for both the magnitude and angle of the injected voltage are also derived. A closed-loop controller that consists of an inner current loop and an outer voltage loop is also incorporated into the DVR system.


Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1972 ◽  
Author(s):  
Javier Roldán-Pérez ◽  
Aurelio García-Cerrada ◽  
Alberto Rodríguez-Cabero ◽  
Juan Zamora-Macho

Voltage sags result in unwanted operation stops and large economical losses in industrial applications. A dynamic voltage restorer (DVR) is a power-electronics-based device conceived to protect high-power installations against these events. However, the design of a DVR control system is not straightforward and it has some peculiarities. First of all, a DVR includes a resonant (LC) connection filter with a lightly damped resonance. Secondly, the control system of a DVR should work properly regardless of the type of load, which can be linear or non-linear, to be protected. In this paper, a digital state-feedback (SF) controller for a DVR is proposed to address these issues. The design and features of the SF controller are studied in detail. Two pole-placement alternatives are discussed and the system robustness is tested under variations in the system parameters. Furthermore, implementation aspects such as discretization not commonly addressed in the literature are described. The controller is implemented in its incremental form. A decoupling system for the dq-axis dynamics that takes into account system delays and the load current is proposed and analytically studied. The proposed controller is compared with two other alternatives found in the literature: a Proportional-Integral-Differential (PID) controller and a cascade controller. The effect of the load connected downstream a DVR is also studied, revealing the potential of the SF controller to damp the resonance under light load conditions. All control system developments were tested in a 5 kVA prototype of a DVR connected to a configurable grid.


2015 ◽  
Vol 2 (4) ◽  
pp. 1-6
Author(s):  
K. Venkateswarlu ◽  
◽  
B. Ashwin Kumar ◽  
N. Srinivas ◽  
V. Mallikarjuna Rao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document