Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis

2017 ◽  
Vol 2 (1) ◽  
Author(s):  
Man He ◽  
Bin Hu ◽  
Beibei Chen ◽  
Zucheng Jiang

Abstract Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.

2014 ◽  
Vol 29 (11) ◽  
pp. 2136-2145 ◽  
Author(s):  
Kazumi Inagaki ◽  
Shin-ichiro Fujii ◽  
Shin-ichi Miyashita ◽  
Keisuke Nagasawa ◽  
Tetsuya Okahashi ◽  
...  

A novel concentric type grid nebulizer (CGrid) was developed for sample introduction into an inductively coupled plasma optical emission spectrometer (ICP-OES).


Author(s):  
Masoud Aghahoseini ◽  
Gholamhassan Azimi ◽  
M. K. Amini

Determination of traces of Cd, Co, Cu, Mn and Pb elements in zirconium and its alloys by inductively coupled plasma optical emission spectrometry (ICP OES) suffers from severe spectral interferences...


Sign in / Sign up

Export Citation Format

Share Document