Tolerance for Clock Variance of LF-Band Wireless SS Communication Utilizing Peak Detection with Maximum Determination at the Center of Section Method

2009 ◽  
Vol 129 (12) ◽  
pp. 1195-1200
Author(s):  
Yukihiko Wada ◽  
Hajime Nakajima ◽  
Kazuhiko Sumi
2020 ◽  
Vol 56 (4) ◽  
pp. 375-385
Author(s):  
P. S. Zavyalov ◽  
D. R. Khakimov ◽  
A. A. Gushchina ◽  
A. V. Ermolenko ◽  
D. V. Skokov ◽  
...  
Keyword(s):  

2021 ◽  
Vol 20 (1) ◽  
pp. 1-15
Author(s):  
Qi Zhang ◽  
Zheng Xu ◽  
Yutong Lai

Abstract Hi-C experiments have become very popular for studying the 3D genome structure in recent years. Identification of long-range chromosomal interaction, i.e., peak detection, is crucial for Hi-C data analysis. But it remains a challenging task due to the inherent high dimensionality, sparsity and the over-dispersion of the Hi-C count data matrix. We propose EBHiC, an empirical Bayes approach for peak detection from Hi-C data. The proposed framework provides flexible over-dispersion modeling by explicitly including the “true” interaction intensities as latent variables. To implement the proposed peak identification method (via the empirical Bayes test), we estimate the overall distributions of the observed counts semiparametrically using a Smoothed Expectation Maximization algorithm, and the empirical null based on the zero assumption. We conducted extensive simulations to validate and evaluate the performance of our proposed approach and applied it to real datasets. Our results suggest that EBHiC can identify better peaks in terms of accuracy, biological interpretability, and the consistency across biological replicates. The source code is available on Github (https://github.com/QiZhangStat/EBHiC).


Author(s):  
Aram Radnia ◽  
Hamed Abdollahzadeh ◽  
Behnoosh Teimourian ◽  
Mohammad Hossein Farahani ◽  
Mohammad Esmaeil Akbari ◽  
...  

Abstract Background A gamma probe is a handheld device used for intraoperative interventions following interstitial injection of a radiotracer to locate regional lymph nodes through the external detection of radiation. This work reports on the design and performance evaluation of a novel fully integrated gamma probe (GammaPen), recently developed by our group. Materials and methods GammaPen is an all-in-one pocket gamma probe with low weight and adequate dimensions, consisting of a detector, a control unit and output all together. The detector module consists of a cylindrical Thallium-activated Cesium Iodide [CsI (Tl)] crystal optically coupled to a Silicon photomultiplier (SiPM), shielded using Tungsten housing on side and back faces. The electronics of the probe consists of two small boards to handle signal processing and analog peak detection tasks. A number of parameters, including probe sensitivity in air/water, spatial resolution in air/water, angular resolution in air/water, and side and back shielding effectiveness, were measured to evaluate the performance of the probe based on NEMA NU3-2004 standards. Results The sensitivity of the probe in air at distances of 10, 30, and 50 mm is 18784, 3500, and 1575 cps/MBq. The sensitivity in scattering medium was also measured at distances of 10, 30, and 50 mm as 17,680, 3050, and 1104 cps/MBq. The spatial and angular resolutions in scattering medium were 47 mm and 87 degree at 30 mm distance from the probe, while they were 40 mm and 77 degree in air. The detector shielding effectiveness and leakage sensitivity are 99.91% and 0.09%, respectively. Conclusion The performance characterization showed that GammaPen can be used effectively for sentinel lymph node localization. The probe was successfully used in several surgical interventions by an experienced surgeon confirming its suitability in a clinical setting.


2021 ◽  
Vol 68 ◽  
pp. 102606
Author(s):  
Erick Javier Argüello Prada ◽  
Carlos Alberto Bravo Gallego ◽  
Javier Ferney Castillo García

2021 ◽  
Vol 32 (4) ◽  
pp. 913-928
Author(s):  
Trina Mouchahoir ◽  
John E. Schiel ◽  
Rich Rogers ◽  
Alan Heckert ◽  
Benjamin J. Place ◽  
...  

1972 ◽  
Vol 7 (2) ◽  
pp. 151-156 ◽  
Author(s):  
D J Hitchings ◽  
A R Luxmoore

A high-speed scanning system has been developed to locate the centres of moiré fringes along any single line. The system comprises a rotating-mirror scanner for conversion of an optical signal to electrical; this conversion is followed by peak detection, storage, and print-out electronics. Up to 20 fringes can be scanned in 1 ms. The results are printed in terms of fringe separations along the scanning line.


Sign in / Sign up

Export Citation Format

Share Document