scholarly journals Cervical stenosis and pregnancy rate after ultrasound guided cervical dilation in women undergoing saline infusion sonography

2020 ◽  
Vol 20 (81) ◽  
pp. e116-e121
Author(s):  
Rubina Izhar ◽  
◽  
Samia Husain ◽  
Muhammad Ahmad Tahir ◽  
Sonia Husain ◽  
...  
2020 ◽  
Vol 103 (6) ◽  
pp. 585-593

Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy


2016 ◽  
Vol 5 (41) ◽  
pp. 2498-2502
Author(s):  
Poornima Maravi ◽  
Vijay Verma ◽  
Lovely Kaushal ◽  
Abhjeet Patil ◽  
Chandraprakash Ahirwar

2021 ◽  
Author(s):  
Tingting Yang ◽  
Bo Chen ◽  
Xiaoyan Sun ◽  
Qingyang Li ◽  
Qiumei Li ◽  
...  

Abstract Background So far, only few literatures have studied the relationship between blastocyst transfer position and ART outcomes, and the conclusions are still controversial. Our study is to evaluate the effect of air bubble position on ART outcome and to find the optimal embryo transfer position in frozen-thawed blastocyst transfer. Methods This study included a retrospective cohort analysis of 399 frozen-thawed single blastocyst transfers ultrasound-guided performed between June 1, 2017 and November 30, 2020. All of the women scheduled for frozen-thawed single blastocyst transfers ultrasound-guided. The primary outcome is clinical pregnancy rate and the secondary outcome is live birth rate. Statistical analyses were conducted using One-way Anova, Kruscal Whallis H test, chi-square test and Smooth curve fitting. Results When BFD was less than 19 mm, there was no significant change in clinical pregnancy rate as BFD increased (OR = 0.95, 95% CI: 0.89 to 1.02, P = 0.1373); when BFD was more than 19 mm, the clinical pregnancy rate decreased by 16% for every 1 mm increase in BFD (OR = 0.84, 95% CI: 0.72 to 0.98, P = 0.0363). The effect of BFD on live birth rate were similar to that on clinical pregnancy rate, the inflection point was 19mm, when BFD was more than 19 mm, the live birth rate decreases by 58% for every 1 mm increase in BFD (OR = 0.42, 95% CI: 0.21 to 0.86, P = 0.0174) Conclusions The ideal pregnancy outcome can be achieved within 19mm from uterus fundus after single blastocyst transfer, The clinical pregnancy and live birth at a distance of more 19mm from the uterus fundus have a cliff-like downward trend.


2017 ◽  
Vol 29 (5) ◽  
pp. 931 ◽  
Author(s):  
S. Björkman ◽  
J. Yun ◽  
M. Niku ◽  
C. Oliviero ◽  
N. M. Soede ◽  
...  

The aims of the present study was to develop and describe a transvaginal ultrasound-guided biopsy method for luteal tissue in the porcine and to evaluate the effects of the method on the reproductive tract, ovarian status and pregnancy status. Biopsies were performed in four multiparous sows on Days 9 and 15 of three consecutive oestrous cycles; the size and histological composition of the samples obtained were evaluated and the reproductive tract of the sows was monitored. Furthermore, biopsies were performed in 26 multiparous sows on Days 10 and 13 after insemination, and the pregnancy rate, gestation length and subsequent litter size were evaluated. RNA was extracted from the samples obtained and the quality and quantity were determined. Altogether, 76 biopsies were performed and 38 samples were obtained. Compared with sows from which no samples were obtained (n = 6), sows from which one or more samples were obtained (n = 24) were older (parity 5.0 ± 2.8 vs 2.2 ± 0.4, mean ± s.d.), heavier (290 ± 26 vs 244 ± 27 kg) and had higher back fat (11.4 ± 2.7 vs 6.4 ± 2.5 mm; P < 0.05 for all). No effect of the biopsies (P > 0.05) was observed on the cyclicity and reproductive organs of the sows, or on corpus luteum diameter on Day 13 (8.9 ± 1.0 vs 9.2 ± 1.1 mm), pregnancy rate (95% vs 96%), gestation length (115 ± 1 vs 115 ± 1 days) and subsequent litter size (12.7 ± 2.5 vs 13.3 ± 2.8) between sows from which samples were obtained and those from which no samples were obtained. The samples obtained had a diameter of 1 mm and contained heterogeneous tissue with various cell types. The RNA quantity was 520 ± 160 µg per sample and the RNA integrity number was 8.5 ± 1.0. In conclusion, an ultrasound-guided biopsy method for ovarian tissue, which can be used for gene expression studies, was established in the porcine. No effect on corpus luteum function was found.


Sign in / Sign up

Export Citation Format

Share Document