scholarly journals Accuracy of chest auscultation in detecting abnormal respiratory mechanics in the immediate postoperative period after cardiac surgery

2019 ◽  
Vol 45 (5) ◽  
Author(s):  
Glaciele Xavier ◽  
César Augusto Melo-Silva ◽  
Carlos Eduardo Ventura Gaio dos Santos ◽  
Veronica Moreira Amado

ABSTRACT Objective: To investigate the accuracy of chest auscultation in detecting abnormal respiratory mechanics. Methods: We evaluated 200 mechanically ventilated patients in the immediate postoperative period after cardiac surgery. We assessed respiratory system mechanics - static compliance of the respiratory system (Cst,rs) and respiratory system resistance (R,rs) - after which two independent examiners, blinded to the respiratory system mechanics data, performed chest auscultation. Results: Neither decreased/abolished breath sounds nor crackles were associated with decreased Cst,rs (≤ 60 mL/cmH2O), regardless of the examiner. The overall accuracy of chest auscultation was 34.0% and 42.0% for examiners A and B, respectively. The sensitivity and specificity of chest auscultation for detecting decreased/abolished breath sounds or crackles were 25.1% and 68.3%, respectively, for examiner A, versus 36.4% and 63.4%, respectively, for examiner B. Based on the judgments made by examiner A, there was a weak association between increased R,rs (≥ 15 cmH2O/L/s) and rhonchi or wheezing (ϕ = 0.31, p < 0.01). The overall accuracy for detecting rhonchi or wheezing was 89.5% and 85.0% for examiners A and B, respectively. The sensitivity and specificity for detecting rhonchi or wheezing were 30.0% and 96.1%, respectively, for examiner A, versus 10.0% and 93.3%, respectively, for examiner B. Conclusions: Chest auscultation does not appear to be an accurate diagnostic method for detecting abnormal respiratory mechanics in mechanically ventilated patients in the immediate postoperative period after cardiac surgery.

1998 ◽  
Vol 74 (4) ◽  
pp. 275-83
Author(s):  
Antônio C. P. Ferreira ◽  
Benjamin I. Kopelman ◽  
Werther Brunow de Carvalho ◽  
Jorge Bonassa

1985 ◽  
Vol 58 (6) ◽  
pp. 1849-1858 ◽  
Author(s):  
A. Rossi ◽  
S. B. Gottfried ◽  
B. D. Higgs ◽  
L. Zocchi ◽  
A. Grassino ◽  
...  

In 11 mechanically ventilated patients, respiratory mechanics were measured 1) during constant flow inflation and 2) following end-inflation airway occlusion, as proposed in model analysis (J. Appl. Physiol. 58: 1840–1848, 1985. During the latter part of inflation, the relationship between driving pressure and lung volume change was linear, allowing determination of static respiratory elastance (Ers) and resistance (RT). The latter represents in each patient the maximum resistance value that can obtain with the prevailing time constant inhomogeneity. Following occlusion, Ers and RT were also obtained along with RT (min) which represents a minimum, i.e., resistance value that would obtain in the absence of time constant inhomogeneity. A discrepancy between inflation and occlusion Ers and RT was found only in the three patients without positive end-expiratory pressure, and could be attributed to recruitment of lung units during inflation. In all instances Ers and RT were higher than normal. RT(min) was lower in all patients than the corresponding values of RT, indicating that resistance was frequency dependent due to time constant inequalities. Changes in inflation rate did not affect Ers, while RT increased with increasing flow.


Sign in / Sign up

Export Citation Format

Share Document