scholarly journals The effect of membrane biocompatibility on plasma beta 2-microglobulin levels in chronic hemodialysis patients.

1996 ◽  
Vol 7 (3) ◽  
pp. 472-478
Author(s):  
R M Hakim ◽  
R L Wingard ◽  
L Husni ◽  
R A Parker ◽  
T F Parker

Several studies have shown that patients who have been dialyzed with high-flux biocompatible membranes have a lower plasma level of beta 2-microglobulin and a lower incidence of amyloid disease compared with patients who have been dialyzed with low-flux bioincompatible membranes. However, because high-flux membranes are associated with significant dialytic removal of beta 2-microglobulin, the specific role of membrane biocompatibility in influencing the rate of increase of beta 2-microglobulin has not been previously determined. This study investigated the effect of biocompatibility on the rate of increase of plasma levels of beta 2-microglobulin in 159 new hemodialysis patients from 13 dialysis centers (ten centers affiliated with Dallas Nephrology Associates and three with Vanderbilt University Medical Center) by using two low-flux membranes with widely different biocompatibilities. These patients were prospectively randomized to be dialyzed with either a low-flux biocompatible membrane or a low-flux bioincompatible membrane. Plasma beta 2-microglobulin levels were measured at 0, 3, 6, 9, 12, and 18 months. Sixty-six patients completed the 18-month study. Plasma beta 2-microglobulin increased in all patients; however, the increase was not significantly different from baseline at any time point in the group that used the biocompatible membrane. In this group, beta 2-microglobulin increased from (mean +/- SD) 27.8 +/- 14.8 mg/L to 34.0 +/- 10.0 mg/L at 18 months (P = not significant), and the mean increase at 18 months was 2.6 +/- 14.7 mg/L. In contrast, the increase in plasma beta 2-microglobulin level in the bioincompatible membrane group became significant in Month 6 when the levels had increased from a baseline of 24.8 +/- 9.6 mg/L to 29.5 +/- 12.2 mg/L (P < 0.001); these increases continued to be significant until Month 18, when serum beta 2-microglobulin reached 36.8 +/- 13.9 mg/L with an average increase of 11.8 +/- 11.2 mg/L (P < 0.0001). The higher rate of plasma B2-microglobulin increase in the group that had been dialyzed with the bioincompatible membrane was also evident when only patients who had completed the study were analyzed. There were no significant differences in the actual level of beta 2-microglobulin or in residual renal function between the two groups during the 18 months of the study. It was concluded that over a period of 18 months, the use of biocompatible membranes, even in the low-flux configuration, is associated with a significantly slower increase in plasma beta 2-microglobulin, independent of the influence of residual renal function.

2001 ◽  
Vol 19 (3) ◽  
pp. 301-307 ◽  
Author(s):  
Chun-Liang Lin ◽  
Chih-Wei Yang ◽  
Chin-Chen Chiang ◽  
Ching-Tung Chang ◽  
Chiu-Ching Huang

Medicine ◽  
1989 ◽  
Vol 68 (2) ◽  
pp. 107-115 ◽  
Author(s):  
MICHAEL E. ULLIAN ◽  
WILLIAM S. HAMMOND ◽  
ALLEN C. ALFREY ◽  
ARNOLD SCHULTZ ◽  
BRUCE A. MOLITORIS

2016 ◽  
Vol 70 (5) ◽  
pp. 348 ◽  
Author(s):  
Valdete TopciuShufta ◽  
Ram Miftari ◽  
Valdete Haxhibeqiri ◽  
Shpend Haxhibeqiri

Nephron ◽  
1993 ◽  
Vol 65 (3) ◽  
pp. 469-471 ◽  
Author(s):  
Gianpaolo Amici ◽  
Giovambattista Virga ◽  
Giorgio Da Rin ◽  
Stefano Grandesso ◽  
Alberto Vianello ◽  
...  

2017 ◽  
Vol 32 (suppl_3) ◽  
pp. iii629-iii630
Author(s):  
Carla Moreira ◽  
Liliana Cunha ◽  
Maria Carvalho ◽  
José Oliveira ◽  
Olívia Santos ◽  
...  

Nephron ◽  
1989 ◽  
Vol 53 (1) ◽  
pp. 87-87 ◽  
Author(s):  
Hisashi Ozasa ◽  
Toshiaki Suzuki ◽  
Kazuo Ota

1998 ◽  
Vol 9 (3) ◽  
pp. 464-472
Author(s):  
B V Murthy ◽  
S Sundaram ◽  
B L Jaber ◽  
C Perrella ◽  
K B Meyer ◽  
...  

Among the several disadvantages of reprocessed dialyzers is the concern that reuse could decrease the clearance of uremic toxins, leading to a decrease in the delivered dose of dialysis. To examine this possibility in the clinical setting, the clearances of small molecular weight solutes (urea and creatinine) and middle molecular weight substances (beta 2 microglobulin) were compared during dialysis with "high-efficiency" cellulose (T220L) and "high-flux" polysulfone (F80B) dialyzers reprocessed with formaldehyde and bleach. In a crossover study, six chronic hemodialysis patients were alternately assigned to undergo 21 dialysis treatments with a single T220L dialyzer or F80B dialyzer. Each patient was studied during first use (0 reuse), 2nd reuse (3rd use), and 5th, 10th, 15th, and 20th reuse of each dialyzer. Urea, creatinine, and beta 2 microglobulin clearances were measured at blood flow rates of 300 ml/min (Qb 300) and 400 ml/min (Qb 400). Total albumin loss into the dialysate was measured during each treatment. Urea or creatinine clearance of new T220L dialyzers was not significantly different from that of new F80B dialyzers at either Qb. Urea clearance of F80B dialyzers at Qb 300 decreased from 241 +/- 2 ml/min for new dialyzers to 221 +/- 5 ml/min after 20 reuses (P < 0.001), and Qb 400 from 280 +/- 4 ml/min for new dialyzers to 253 +/- 7 ml/min after 20 reuses (P = 0.001). Similarly, with reuse, creatinine clearance of F80B dialyzers also decreased at Qb 300 (P = 0.07) and Qb 400 (P = 0.03). In contrast, urea or creatinine clearance of T220L dialyzers did not decrease with reuse at either Qb. Urea clearance of T220L dialyzers was significantly higher than that of F80B at Qb 300 at the 5th, 10th, 15th, and 20th reuse (P < 0.001, = 0.005, = 0.004, and = 0.006, respectively), and Qb 400 at the 2nd, 5th, 10th, 15th, and 20th reuse (P = 0.04, 0.008, 0.03, 0.02, and 0.008, respectively). Beta 2 microglobulin clearance of T220L dialyzers was < 5.0 ml/min across the reuses studied. Beta 2 microglobulin clearance of F80B was < 5.0 ml/min for new dialyzers, but increased to 21.2 +/- 5.3 ml/min (Qb 300) and 23.6 +/- 3.3 ml/min (Qb 400) after 20 reuses (P < 0.001). Throughout the study, albumin was undetectable in the dialysate with T220L dialyzers. With F80B dialyzers, albumin was detected in the dialysate in four instances (total loss during dialysis, 483 mg to 1.467 g). In summary, the results of this study emphasize the greater need for information on dialyzer clearances during clinical dialysis, especially with reprocessed dialyzers. A more accurate knowledge of dialyzer performance in vivo would help to ensure that the dose of dialysis prescribed is indeed delivered to the patients.