scholarly journals Micro-computed tomography assessment of dentinal microcracks after the preparation of curved root canals with rotary and reciprocal systems

2021 ◽  
Vol 58 (4) ◽  
pp. 515-523
Author(s):  
Yazdan Shantiaee ◽  
Babak Zandi ◽  
Shiva Shojaeian ◽  
Niloofar Mortezapour ◽  
Fatemeh Soltaninejad
2019 ◽  
Vol 25 ◽  
pp. 6351-6358
Author(s):  
Gabrielė Česaitienė ◽  
Tadas Venskutonis ◽  
Vita Mačiulskienė ◽  
Vaidotas Cicėnas ◽  
Vykintas Samaitis ◽  
...  

2016 ◽  
Vol 42 (5) ◽  
pp. 803-808 ◽  
Author(s):  
Giselle Nevares ◽  
Diana S. de Albuquerque ◽  
Laila G. Freire ◽  
Kaline Romeiro ◽  
Howard M. Fogel ◽  
...  

2013 ◽  
Vol 40 (2) ◽  
pp. 76-80 ◽  
Author(s):  
Baran Can Sağlam ◽  
Mustafa Murat Koçak ◽  
Sevinç Aktemur Türker ◽  
Sibel Koçak

2015 ◽  
Vol 48 (8) ◽  
pp. 814-814
Author(s):  
D. A. de Meireles ◽  
T. C. C. A. de Brito ◽  
A. A. F. Marques ◽  
A. D. B. Garrido ◽  
L. F. R. Garcia ◽  
...  

2011 ◽  
Vol 37 (9) ◽  
pp. 1296-1300 ◽  
Author(s):  
Sung-Yeop You ◽  
Hyeon-Cheol Kim ◽  
Kwang-Shik Bae ◽  
Seung-Ho Baek ◽  
Kee-Yeon Kum ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ibrahim Faisal ◽  
Rajab Saif ◽  
Mona Alsulaiman ◽  
Zuhair S. Natto

Abstract Background Various systems of nickel-titanium (NiTi) instrument have long been commercially available. However, the preparation of narrow and curved root canals has always been challenging. The purpose of this study was to compare the shaping ability of two NiTi systems (2Shape and NeoNiTi) in severely curved root canals with different morphological patterns using micro-computed tomography (Micro-CT). Methods A total of 22 human extracted permanent teeth of mandibular first molars, with the exact mesial angle of curvature of 25 and 35 degrees, according to Schneider’s technique, were distributed randomly into two groups (group I: 2Shape, group II: NeoNiTi) based on the rotary system used (n = 22). The groups were subdivided into two subgroups corresponding to the angle of canal curvature (25° and 35°) (n = 11). Canals were scanned using Micro-CT pre- and post-preparation to assess the volume of dentin removed; canal transportation; and canal centering ratio at 3, 6, and 9 mm from the apex. The Mann–Whitney U test was utilized to determine any significant differences between the two systems. The level of statistical significance was set at p < 0.05. Results There was no significant difference between the two groups in volume of dentin removed; canal transportation; and centering ability for 25° and 35° canal curvatures at 3, 6, and 9 mm from the apex (coronal, middle, and apical) thirds (p > 0.05). At the middle third, the NeoNiTi group demonstrated a statistically significant increase in volume of dentin removed for 35° canal curvatures compared to the 2Shape group. Conclusion Within the limitation of our in vitro study, 2Shape and NeoNiTi systems with severely curved canals were confirmed to be relatively safe in preparation and to respect original canal anatomy. Nevertheless, NeoNiTi instruments produced more centered preparation and minimal canal deviation compared to the 2Shape system.


Sign in / Sign up

Export Citation Format

Share Document