scholarly journals USE OF THE INTRAOPERATIVE OCT OF THE ANTERIOR SEGMENT OF THE EYE DURING ACCELERATED CROSSLINKING ON THE "THIN" CORNEA

Author(s):  
A.V. Tereschenko ◽  
S.K. Demyanchenko ◽  
Y.Y. Golubeva ◽  
E.N. Vishnyakova
2018 ◽  
Vol 46 (6) ◽  
pp. 2474-2480 ◽  
Author(s):  
Om Prakash Pant ◽  
Ji-long Hao ◽  
Dan-dan Zhou ◽  
Fan Wang ◽  
Cheng-wei Lu

Small incision lenticule extraction (SMILE) is a minimally invasive, safe and flapless femtosecond laser technique used mainly to correct myopia through extraction of a corneal lenticule. Lenticules obtained in this way are transparent and of high quality, and thus, can be used to treat other corneal diseases. A 65-year-old male patient presented with recurrent pterygium complicated by thin cornea. The patient was treated surgically using a SMILE-extracted lenticule to avoid further complications and to maintain eyeball integrity. The lenticule was sutured over the thin section of cornea using 10-0 interrupted nylon sutures and enclosed by a single layer of amniotic membrane. The patient was evaluated using slit-lamp biomicroscopy and anterior-segment optical-coherence tomography. During an 8-month follow-up, the graft remained intact with no sign of rejection and corneal thickness was maintained. Tectonic keratoplasty using a SMILE-extracted lenticule appears to be a safe, cost-effective and reliable method for treating thin cornea due to repeated surgeries for recurrent pterygium. This is the first case of recurrent pterygium complicated by thin cornea managed surgically using a SMILE-extracted lenticule.


2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Jiri Cendelin ◽  
Stepan Rusnak ◽  
Lenka Hecova

Aim of the Study. The aim of this prospective study was to analyse the effect of lateral stromal hydration on the morphology of clear corneal incision architecture using the microscope integrated anterior segment OCT. Methods. The cohort included 65 clear corneal incisions of 49 patients who underwent cataract surgery. Corneal incisions were recorded using a Leica Proveo 8 microscope with an intraoperative OCT EnFocus™ device continuously during the surgery. Corneal incision morphology before and after lateral stromal hydration was analysed. Results. Good adaptation of the corneal incision before hydration was present in 39 cases (60%), in 16 cases (24.6%), the prominence of posterior lip was present, and, in 10 cases (15.4%), the posterior lip tongue was inverted/retracted into the incision. In 38 cases (58.5%), hydration had no effect on the incision architecture; most often, it was primarily a well-adapted corneal incision (46.2%), less often an incision with posterior lip prominence (10.8%), or tongue inversion into the incision (1.6%) prior to hydration. Hydration worsened the incision architecture in 14 cases (21.5%); most often, it induced/worsened posterior lip prominence (15.4%), less often posterior lip retraction (1.6%), tongue inversion into the incision (1.6%), gap development in the peripheral part of the corneal incision (1.6%), or incomplete opening of the corneal incision (1.6%). In 13 cases (20%), hydration improved the incision architecture, especially in cases with inverted or retracted posterior lip tongue (12.3%), less often in cases with posterior lip prominence (7.7%). Conclusion. Lateral stromal hydration seldom affects the condition of the corneal incision. Still, it can cause both deterioration and improvement of the corneal incision architecture. Intraoperative OCT provides real-time monitoring of corneal incision morphology during hydration procedure.


2021 ◽  
Vol 1 (5) ◽  
pp. 164-171

Purpose. To compare the intraoperative OCT (optical coherence tomographer) of the femtosecond laser LenSx (Alcon Pharma GmbH, Freiburg) with a Scheimpflug-tomographer and an anterior segment OCT and thus to investigate a possible influence on the anterior segment of the eye when docking the patient’s interface. Material and Methods. A prospective cross-sectional study was conducted with 57 subjects who underwent a planned femtosecond laser-assisted cataract surgery or refractive lens exchange. The eye to be operated on was measured prior to the operation in mydriasis with the Visante OCT (Carl Zeiss Meditec AG, Jena) and the Pentacam AXL (Oculus Optikgeräte GmbH, Wetzlar). During the surgery, images of the anterior segment of the eye were taken by the integrated intraoperative OCT of the laser, which were evaluated afterwards and compared to the values of the other devices. The parameters examined were the internal anterior chamber depth (ACD), nasal and temporal chamber angles, central corneal thickness (CCT) and central lens thickness (LT). Results. The comparison of the intraoperative OCT and the two other devices showed clinically relevant differences in all parameters. The intraoperative OCT showed a 9.19 ± 27.55 μm larger CCT, 0.96 mm (median difference) larger LT, 0.05 mm smaller ACD than the Pentacam AXL and a 21.36 ± 25.50 μm larger CCT, 0.10 mm (median difference) smaller ACD than the Visante OCT. Conclusion. The comparison of the intraoperative OCT with the Visante OCT and the Pentacam AXL shows clinically relevant differences. Changes in the anterior segment of the eye may be due to errors in measurement or docking of the patient’s interface. Keywords. femtosecond laser, OCT, anterior segment of the eye, cataract surgery, refractive lens exchange


Author(s):  
Dewang Angmo ◽  
Jyoti Shakrawal ◽  
Ramanjit Sihota

With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue depth allowing better localization and easy maneuvering with lesser complications. In this surgical technique, bleb revision was performed using intraoperative real-time OCT incorporated in OPMI LUMERA 700 microscope. Live surgical and OCT view were seen on a common screen together. A moderately elevated, diffuse functional bleb was noted after three months of bleb revision in both cases with controlled intraocular pressure. Intraoperative OCT-guided bleb-sparing epithelial exchange is an adjunctive technique for bleb repair surgery with an increased precision of surgery which can reduce complications, minimize surgical time and maximize surgical outcome.


2019 ◽  
Author(s):  
Amar Agarwal ◽  
Ashar Agarwal ◽  
Ashvin Agarwal ◽  
Athiya Agarwal ◽  
Sreelakshmi P. Amar ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format