scholarly journals Anterior referencing versus posterior referencing in total knee arthroplasty: a prospective observational study

Author(s):  
Preetesh Choudhary ◽  
Skand Bahre ◽  
Vinay Tantuway ◽  
Ashok Nagla ◽  
Avinash Jain ◽  
...  

<p class="abstract"><strong>Background:</strong> Femoral component rotation in total knee arthroplasty (TKA) is essential for patella-femoral tracking, flexion gap balance and normal kinematic function of the knee. The two referencing techniques used for sizing and adjudging the femoral rotation are anterior referencing (AR) and posterior referencing (PR).The current study was designed so as to identify which referencing system determines the femoral rotation more accurately<span lang="EN-IN">.</span></p><p class="abstract"><strong>Methods:</strong> This study involved 34 consecutive patients (22 females and 12 males) with 60 osteoarthritic knees (bilateral=26; unilateral =8) who satisfied the inclusion criteria. The trans-epicondylar axis, was taken as gold standard to adjudge the correct femoral rotation and was marked as E. The axis of rotation as per anterior instrumentation (A), and as per posterior instrumentation (P) were marked and compared as to which of the axis (A or P) was parallel to E.<strong></strong></p><p class="abstract"><strong>Results:</strong> A was always parallel to E, however P was parallel to E in 42 knees. In 18 knees (6 with valgoid deformity, 12 with hypertrophic osteoarthritis involving the medial femoral condyle), P and E tend to converge laterally, suggestive of excessive internal rotation<span lang="EN-IN">. </span></p><p class="abstract"><strong>Conclusions:</strong> Anterior referencing determines femoral rotation more accurately than posterior referencing for knees with severe valgoid deformity or those with hypertrophic osteoarthritis involving the overgrowth of medial femoral condyle<span lang="EN-IN">.</span></p>

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Liang Yuan ◽  
Bin Yang ◽  
Xiaohua Wang ◽  
Bin Sun ◽  
Ke Zhang ◽  
...  

Purpose. Bony resection is the primary step during total knee arthroplasty. The accuracy of bony resection was highly addressed because it was deemed to have a good relationship with mechanical line. Patient-specific instruments (PSI) were invented to copy the bony resection references from the preoperative surgical plan during a total knee arthroplasty (TKA); however, the accuracy still remains controversial. This study was aimed at finding out the accuracy of the bony resection during PSI-assisted TKA. Methods. Forty-two PSI-assisted TKAs (based on full-length leg CT images) were analyzed retrospectively. Resected bones of every patient were given a CT scan, and three-dimensional radiographs were reconstructed. The thickness of each bony resection was measured with the three-dimensional radiographs and recorded. The saw blade thickness (1.27 mm) was added to the measurements, and the results represented intraoperative bone resection thickness. A comparison between intraoperative bone resection thickness and preoperatively planned thickness was conducted. The differences were calculated, and the outliers were defined as >3 mm. Results. The distal femoral condyle had the most accurate bone cuts with the smallest difference (median, 1.0 mm at the distal medial femoral condyle and 0.8 mm at the distal lateral femoral condyle) and the least outliers (none at the distal medial femoral condyle and 1 (2.4%) at the distal lateral femoral condyle). The tibial plateau came in second (median difference, 0.8 mm at the medial tibial plateau and 1.4 mm at the lateral tibial plateau; outliers, none at the medial tibial plateau and 1 (2.6%) at the lateral tibial plateau). Regardless of whether the threshold was set to >2 mm (14 (17.9%) at the tibial plateau vs. 12 (14.6%) at the distal femoral condyle, p > 0.05 ) or >3 mm (1 (1.3%) at the tibial plateau vs. 1 (1.2%) at the distal femoral condyle, p > 0.05 ), the accuracy of tibial plateau osteotomy was similar to that of the distal femoral condyle. Osteotomy accuracy at the posterior femoral condyle and the anterior femoral condyle were the worst. Outliers were up to 6 (15.0%) at the posterior medial femoral condyle, 5 (12.2%) at the posterior lateral femoral condyle, and 6 (15.8%) at the anterior femoral condyle. The percentages of overcut and undercut tended to 50% in most parts except the lateral tibial plateau. At the lateral tibial plateau, the undercut percentage was twice that of the overcut. Conclusion. The tibial plateau and the distal femoral condyle share a similar accuracy of osteotomy with PSI. PSI have a generally good accuracy during the femur and tibia bone resection in TKA. PSI could be a kind of user-friendly tool which can simplify TKA with good accuracy. Level of Evidence. This is a Level IV case series with no comparison group.


2021 ◽  
Vol 8 ◽  
pp. 222-225
Author(s):  
Ricardo Ocampo ◽  
Eric Azua ◽  
Matthew Presti ◽  
Lynn Voss

Author(s):  
Huitong Liu ◽  
Bingqiang Xu ◽  
Eryou Feng ◽  
Shizhang Liu ◽  
Wei Zhang ◽  
...  

Background: Imaging measurement of distal femur and proximal tibia has been the hot point in the research of total knee arthroplasty and prosthesis development, which is an important treatment for patients with advanced knee joint disease. This study retrospectively investigated the digital imaging measurement of normal knee parameters in southeast China and evaluated their clinical value. Methods: From February 2010 to May 2014, and in accordance with the inclusion criteria, a total of 677 knees (334 female knees and 343 male knees) were categorized into 3 age groups. Clinical and digital imaging data, including the distal femoral condyle diameter (FCD), tibial plateau diameter (TPD), the distance between the medial tibial plateau and fibular head (DPF), tibiofemoral valgus angle, distal femoral valgus angle, proximal tibia (PT) varus angle and the angle from femoral condyle to tibial perpendicular (FT), were measured by using AutoCAD 10.0 software. All measured variables were statistically analyzed by SPSS statistical software (version 18.0). Results: Data are presented as the mean ± standard deviation. The normal female and male femoral condyle diameter was (7.69 ± 0.46) cm and (8.68 ± 0.55) cm, while the normal female and male tibial plateau diameter was (7.66 ± 0.46) cm and (8.60 ± 0.55) cm, respectively. The normal female and male DPF was (0.76 ± 0.36) cm and (0.79 ± 0.36) cm. For females and males, the tibiofemoral valgus angle and distal femoral valgus angle were (3.89 ± 2.20) ° and (3.29 ± 2.12) °, (9.03 ± 2.18) ° and (8.25 ± 2.20) °. As the two methods to measure tibial plateau varus angle, PT angle of normal female and male was (4.29 ± 1.86) ° and (4.84 ± 2.23) °, while the normal female and male FT angle was (5.34 ± 1.95) ° and (5.52 ± 2.07) °. Based on the data obtained, we found significant differences between the two genders in terms of the femoral condyle diameter and tibial plateau diameter in all age groups (P < 0.01). The DPF parameter showed an obvious difference between the young group and the middle-aged group (P < 0.05), and no significant difference was observed between the sides and genders (P > 0.05). The distal femoral valgus angle showed statistical differences between genders in the left side of the young group and middle-aged group (P < 0.05), while angle PT and FT showed no significant difference (P > 0.05). Conclusion: A large number of knee measurements was obtained, and a local knee database was developed in this study. Imaging measurement prior to total knee arthroplasty is clinically important for increasing the accuracy and long-term efficacy of total knee arthroplasty. These data can also provide useful information for knee surgery and sports medicine as well as prosthesis development.


2021 ◽  
pp. 42-44
Author(s):  
Amol K Salve ◽  
Vinod Kumar Yadav ◽  
Ajay M Wankhade ◽  
Tanay Nahatkar ◽  
Sangam Jain

Intro- For TKA, there are two types of bearing designs: xed-bearing and mobile-bearing. Round femoral components articulate with a relatively at tibial articular surface in a xed-bearing knee design. Because the insert does not hinder the natural movements of the femoral component, the mobile-bearing (MB) TKA design is thought to allow more exibility of motion than the xed-bearing (FB) variety. Aim and objective: To compare xed bearing and mobile bearing total knee arthroplasty. Material and methods:This study is a prospective type of study done at Seth GS medical college Mumbai, Department of Orthopaedics during August 2019 to June 2021 on patients undergoing total knee arthroplasty. Patients who were to undergo total knee arthroplasty were invited to take part in the study. This study, done on them was explained in detail to them. An informed consent was obtained. Patients fullling the inclusion criteria were listed. Result: Range of motion achieved after mobile arthroplasty was 123.62±2.94 and in xed arthroplasty it was 121.96±2.74. Pain after last follow up in mobile arthroplasty was 48.83±0.62 and for xed arthroplasty was 47.39±0.86. Flexion gap after last follow up in mobile arthroplasty was 24.13±0.45 and in xed was 24.02±0.45. Stability was almost similar in both mobile and xed arthroplasty. Conclusions: there is no signicant difference between xed arthroplasty and mobile arthroplasty as far as Range of motion, Pain ,Flexion gap. Stability was almost similar in both mobile and xed arthroplasty.


2018 ◽  
Vol 33 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Joshua G. Twiggs ◽  
David M. Dickison ◽  
Elizabeth C. Kolos ◽  
Caitlin E. Wilcox ◽  
Justin P. Roe ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document