scholarly journals Is There an Optimal Positive End-expiratory Pressure to Measure the Internal Jugular Vein Collapsibility Index? A Pilot Study in Mechanically Ventilated Patients

Author(s):  
Alireza Zeraatchi ◽  
Taraneh Naghibi ◽  
Hamid Kafili ◽  
Somayeh Abdollahi Sabet

Background: Hemodynamic monitoring its early stabilization is very important in critically ill patients. Evaluating the Internal jugular vein diameter during respiratory cycles by the means of Point-of care ultrasound provides an important, easily available and precise index for monitoring hemodynamic status; a new method which is called Internal Jugular Vein Collapsibility Index (IJV-CI). Any events that alters intrathoracic volumes and pressures may affect this index. In this study we investigate the effects of various levels of positive end-expiratory pressure on this index. Methods: Thirty mechanically ventilated patients were studied. We used three different PEEP levels (0, 5 and 10 cmH2o) and point-of-care ultrasound evaluation of IJV (Internal Jugular Vein) diameter to determine the IJV-CI. The analysis were performed using SPSS V.25.0. Results: Patients were included men (76.6%) and women (33.3%). The mean age of patients was 39.65±3.4 for men and 42.71± 9.34 for women. The IJV-CI were 20.71±11.77 and 24.25±11.46 in PEEP=0 and PEEP=10 cmH20 groups respectively. In 5cmH20-PEEP group median and interquartile range were 16.45(14.8). The IJV-CI in three different PEEP levels were not statistically significantly different. Conclusion: According to the finding of this study, we found no evidence of an optimal PEEP level to measure The IJV-CI.

1995 ◽  
Vol 23 (2) ◽  
pp. 175-177 ◽  
Author(s):  
P. V. Van Heerden ◽  
W. Jacob ◽  
P. D. Cameron ◽  
S. Webb

Segmental and lobar pulmonary atelectasis is a common occurrence in mechanically ventilated patients. Standard therapy for atelectasis relies on positive pressure ventilation, positive end expiratory pressure (PEEP), tracheobronchial toilet and regular chest physiotherapy. Various adjuncts to physiotherapy such as bronchoscopic clearance of secretions have not proved to be of additional benefit. Bronchoscopic clearance of secretions followed by insufflation of room air at 30 cm H2O into the atelectatic segment was employed on ten occasions in mechanically ventilated patients. Rapid re-expansion of the collapsed segment or lobe occurred in seven out of the ten treatments.


Author(s):  
Awaiz Khan ◽  
Edmundo Rubio ◽  
Bradley Icard

Abstract This project sought to develop a method to provide a clinically meaningful, surrogate measure for viscosity that will help analyze complex biofluids. Goals for this project included precise measurements that differentiate a wide variety of standard viscosities, table-top level of size, and ease-of-use. The design utilized a custom 3D-printed analog of a cone and plate viscometer with an attachment for a smartphone to provide gyroscopic data. The device is currently in the stages of final validation and will ultimately be tested in a 40-patient clinical trial intended to assess efficacy of mucolytic therapy in mechanically ventilated patients.


2019 ◽  
Vol 7 (3) ◽  
pp. 387-391
Author(s):  
Khaled Mohammed Al-Sayaghi ◽  
Hassnaa Eid Shaban Mosa ◽  
Masouda Hassan Atrous ◽  
Azza Hamdi El-Soussi ◽  
Ahmed Youssef Ali ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document