scholarly journals Functional and Anatomical Outcome of Unstable Extra-Articular Distal Radius Fracture Managed with Plaster Immobilization and with External Fixation

Author(s):  
Dr N. Karthikeyan ◽  
Author(s):  
Abhishek Chattopadhyay ◽  
Upal Banerjee ◽  
Prashant Kumar Sinha ◽  
Subarna Misra ◽  
Ananya Chattopadhyay ◽  
...  

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Distal radius fracture is one of the most common fractures. It may be sustained due to low-energy trauma or high-energy trauma. Objectives: To compare the clinical effectiveness of Kirschner wire fixation with and plaster immobilization for patients with fracture of the distal radius.</span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">Interventions Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. About 79 patients with Distal Radial Fractures presented to MGM Medical College and LSK Hospital, Kishanganj between November 2012 and June 2014 were included in the study</span>.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">The majority were men (60.4%). Majority of the patients (69.8%) sustained the injury due to fall. The side of involvement was nearly equal and that there was no predominance of the either sides. In our study, according to AO classification, 31 cases were of Type A, 17 were of Type B and 5 were of Type C. The Anatomical evaluation by Sarmiento’s Criteria showed 33 patients with excellent result, 15 patients with good result and 5 with a fair result. At final follow-up by ‘The Gartland and Werley criteria for functional outcome’ 37 patients had excellent result, 13 had good result, 2 had fair result and 1 had a poor result. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">This study demonstrates that percutaneous Kirschner<strong> </strong>wire pinning is a minimally invasive technique that provides an effective means of maintaining the anatomical<strong> </strong>fracture reduction. It does not required highly skilled<strong> </strong>personnel or sophisticated tools for application. It is a<strong> </strong>suitable method for fixation of displaced Colles fracture with minimal intra-articular involvement. The technique involves a minimal procedure that provides anatomic reduction, fracture fixation, and maintenance of reduction with an adequate method of immobilization.</span></p>


1998 ◽  
Vol 23 (5) ◽  
pp. 920-925 ◽  
Author(s):  
Satoshi Kawaguchi ◽  
Kazuzi Sawada ◽  
Yuki Nabeta ◽  
Mitsuru Hayakawa ◽  
Mitsuhiro Aoki

2006 ◽  
Vol 20 (5) ◽  
pp. 374
Author(s):  
Hans Kreder ◽  
Julie Agel ◽  
Michael McKee ◽  
Emil Schemitsch ◽  
David Stephen ◽  
...  

2021 ◽  
pp. 1-3
Author(s):  
Kunal Shankar ◽  
Vikash M. Harinandan ◽  
Laljee Chaudhary ◽  
Debarshi Jana

Background: Distal radius fracture is more common accounting for 1/6th of the all fractures. With this background, this study was carried out to compare the functional outcome of volar locking plate and external fixator to the displaced intra-articular distal end radius fractures using Modified Mayo Wrist Score (MMWS). Materials and methods: This study included those patients with distal radius fracture attending the Orthopaedic Department of DMCH, Laheriasarai, Bihar, during January 2019 to December 2019. Patients were randomised based on - even and odd day of the week. This included two set of group with twenty patients in each group- one with volar locking plating and other with external fixation. Patients were followed up at 6 months and 1 year. At each follow up, the pain and range of movements were assessed by MMWS score which was entered in Microsoft excel and analysed in SPSS 20. Results: At the end of one year after surgery, we observed that external fixation technique was superior for treating displaced intra-articular comminuted distal end radius fractures than volar locking plate. Conclusion: External fixator showed more advantageous than volar locking plates after 1year of follow up.


Sign in / Sign up

Export Citation Format

Share Document