scholarly journals Dimensional variations of left-sided double-lumen endobronchial tubes

2019 ◽  
Author(s):  
Niels Hegland ◽  
Sebastian Schnitzler ◽  
Jan Ellensohn ◽  
Marc P Steurer ◽  
Markus Weiss ◽  
...  

Abstract Background Tube size selection is critical in ventilating patients` lungs using double-lumen endobronchial tubes (DLTs). Little information about relevant parameters is readily available from manufacturers. The aim of this study is to provide reference data for relevant dimensions of conventionally available DLTs. Methods In this study in a benchmark in-vitro setup, several dimensional parameters of four sizes of left-sided double-lumen endobronchial tubes from six different manufacturers were assessed, such as distances and diameters of tube shaft, cuff lengths and diameters as well the angle at the tip. Results Endobronchial tubes of ostensibly the same size revealed wide variation in measured parameters between brands from different manufacturers. In some parameters, there was an overlap between different sizes from the same manufacturer, i.e. diameters and distances did not increase with increasing nominal endobronchial tube size. The information about dimensions of endobronchial tubes provided by manufacturers’ leaflets is insufficient. Conclusions Endobronchial tube size selection carries unnecessary uncertainty because clinically relevant parameters are unknown and vary considerably between different manufacturers.


2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Niels Hegland ◽  
Sebastian Schnitzler ◽  
Jan Ellensohn ◽  
Marc P. Steurer ◽  
Markus Weiss ◽  
...  

Background. Tube size selection is critical in ventilating patients’ lungs using double-lumen endobronchial tubes (DLTs). Little information about relevant parameters is readily available from manufacturers. The aim of this study is to provide reference data for relevant dimensions of conventionally available DLTs. Methods. In this study in a benchmark in vitro setup, several dimensional parameters of four sizes of left-sided double-lumen endobronchial tubes from six different manufacturers were assessed, such as distances and diameters of tube shaft, cuff lengths, and diameters as well the angle at the tip. Results. Endobronchial tubes of ostensibly the same size revealed wide variation in measured parameters between brands from different manufacturers. In some parameters, there was an overlap between different sizes from the same manufacturer, i.e., diameters and distances did not increase with increasing nominal endobronchial tube size. The information about dimensions of endobronchial tubes provided by manufacturers’ leaflets is insufficient. Conclusions. Endobronchial tube size selection carries unnecessary uncertainty because clinically relevant parameters are unknown and vary considerably between different manufacturers.



2019 ◽  
Author(s):  
Niels Hegland ◽  
Sebastian Schnitzler ◽  
Jan Ellensohn ◽  
Marc P Steurer ◽  
Markus Weiss ◽  
...  

Abstract Background: Tube size selection is critical in ventilating patient`s lungs using double-lumen endobronchial tubes. Little information about relevant parameters is readily available from manufacturers. Methods: In this observational study in a benchmark in-vitro setup, several dimensional parameters of four sizes of left-sided double-lumen endobronchial tubes from six different manufacturers were assessed, such as distances and diameters of tube shaft, cuff lengths and diameters as well the angle at the tip. Results: Endobronchial tubes of ostensibly the same size revealed wide variation in measured parameters between brands from different manufacturers. In some parameters, there was an overlap between different sizes from the same manufacturer, i.e. diameters and distances did not increase with increasing nominal endobronchial tube size. The information about dimensions of endobronchial tubes provided by manufacturers’ leaflets is insufficient. Conclusions: Endobronchial tube size selection is complicated because clinically relevant parameters are unknown and vary considerably between different manufacturers. Keywords: Airway management, double-lumen endobronchial tubes



2016 ◽  
Vol 32 ◽  
pp. 1-3 ◽  
Author(s):  
Gianluca Zani ◽  
Maitan Stefano ◽  
Bizzarri Federico Tommaso ◽  
Rispoli Marco ◽  
Buono Salvatore ◽  
...  


1995 ◽  
Vol 28 (2) ◽  
pp. 210
Author(s):  
Young Cheol Woo ◽  
Hun Cho ◽  
Hae Ja Lim ◽  
Nan Suk Kim ◽  
Seong Ho Chang


2020 ◽  
Vol 9 (2) ◽  
pp. 62
Author(s):  
AntonioMiranda da Cruz-Filho ◽  
LuisEduardo Souza-Flamini ◽  
BrunoMonguilhott Crozeta ◽  
RicardoGariba Silva ◽  
RicardoNovak Savioli ◽  
...  


2020 ◽  
Author(s):  
Austin C. Cao ◽  
Shruthi Rereddy ◽  
Natasha Mirza


Sign in / Sign up

Export Citation Format

Share Document