The National Shipbuilding Research Program. Analysis of Wash Water Treatment Efficiency for Copper and Zinc

2000 ◽  
Author(s):  
Thomas J. Fox ◽  
Thomas Beacham ◽  
Gary Schafran
2018 ◽  
Vol 40 (4) ◽  
pp. 179-184 ◽  
Author(s):  
Sang-Goo Kim ◽  
Hee-Jong Son ◽  
Young-Do Hwang ◽  
Hoon-Sik Yoom ◽  
Hong-Ki Park

1950 ◽  
Vol 42 (4) ◽  
pp. 626-630
Author(s):  
E. E. Rickert ◽  
W. T. Bishop

2019 ◽  
Vol 124 ◽  
pp. 01029
Author(s):  
A. A. Filimonova ◽  
N. D. Chichirova ◽  
A. A. Chichirov ◽  
A. I. Minibaev

The main sources of highly concentrated multicomponent technological solutions at thermal power plants (TPPs) are water treatment plants. Analysis of operation of the ion-exchange water treatment plant at the Nizhnekamsk Thermal Power Plant-1 showed that half of alkali supplied to regeneration of the anion-exchange alkali filters is not used, but is discharged for neutralization and then to wastewater. Due to the fact that the cost of alkali used in technological processes is quite high, it is economically feasible to process the alkaline waste with the alkali extraction and its reuse in the production cycle. The article presents the experimental results on the electro-membrane separation of alkaline waste regeneration solutions and wash water after anion-exchange filter regeneration. The revealed differences in the selectivity of various ion transfer through the electrodialysis apparatus membranes, depending on time and amount of transmitted electricity, allowed us to establish the possibility of obtaining an alkaline solution purified from impurities.


Sign in / Sign up

Export Citation Format

Share Document