ScienceGate
Advanced Search
Author Search
Journal Finder
Blog
Sign in / Sign up
ScienceGate
Search
Author Search
Journal Finder
Blog
Sign in / Sign up
PARTIAL VOLUME EFFECT CORRECTION IN PET/CT WITH 11C-METHIONINE FOR THE PATIENTS WITH LUNG LESIONS
Russian Electronic Journal of Radiology
◽
10.21569/2222-7415-2021-11-3-107-119
◽
2021
◽
Vol 11
(3)
◽
pp. 107-119
Author(s):
M.S. Tlostanova
◽
◽
L.A. Chipiga
◽
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Lung Lesions
◽
Partial Volume
◽
Partial Volume Effect Correction
◽
Pet Ct
Download Full-text
Related Documents
Cited By
References
Application of Partial Volume Effect Correction and 4D PET in the Quantification of FDG Avid Lung Lesions
Molecular Imaging and Biology
◽
10.1007/s11307-014-0776-6
◽
2014
◽
Vol 17
(1)
◽
pp. 140-148
◽
Cited By ~ 26
Author(s):
Ali Salavati
◽
Samuel Borofsky
◽
Teo K. Boon-Keng
◽
Sina Houshmand
◽
Benjapa Khiewvan
◽
...
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Lung Lesions
◽
Partial Volume
◽
Partial Volume Effect Correction
Download Full-text
Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
Annals of Nuclear Medicine
◽
10.1007/s12149-013-0773-x
◽
2013
◽
Vol 27
(10)
◽
pp. 924-930
◽
Cited By ~ 2
Author(s):
Alexandre R. Krempser
◽
Roberto M. Ichinose
◽
Antonio M. F. L. Miranda de Sá
◽
Silvia M. Velasques de Oliveira
◽
Michel P. Carneiro
Keyword(s):
Volume Effect
◽
Ct Images
◽
Partial Volume Effect
◽
Field Of View
◽
Partial Volume
◽
Partial Volume Effect Correction
◽
Pet Ct
Download Full-text
Partial Volume Effect Correction
Physiological Imaging of the Brain with PET
◽
10.1016/b978-012285751-5/50013-2
◽
2001
◽
pp. 65-71
◽
Cited By ~ 1
Author(s):
Mark Slifstein
◽
Osama Mawlawi
◽
Marc Laruelle
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Partial Volume
◽
Partial Volume Effect Correction
Download Full-text
INVESTIGATION OF PARTIAL VOLUME EFFECT IN DIFFERENT PET/CT SYSTEMS: A COMPARISON OF RESULTS USING THE MADEIRA PHANTOM AND THE NEMA NU-2 2001 PHANTOM
Radiation Protection Dosimetry
◽
10.1093/rpd/ncw027
◽
2016
◽
Vol 169
(1-4)
◽
pp. 365-370
◽
Cited By ~ 2
Author(s):
L. Chipiga
◽
M. Sydoff
◽
I. Zvonova
◽
C. Bernhardsson
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Partial Volume
◽
Comparison Of Results
◽
Pet Ct
Download Full-text
Optimization of an iterative SPECT reconstruction algorithm utilizing a partial volume effect correction method
2013 IEEE 17th International Conference on Intelligent Engineering Systems (INES)
◽
10.1109/ines.2013.6632804
◽
2013
◽
Author(s):
Gabor Hesz
◽
Akos Szlavecz
◽
Balazs Benyo
Keyword(s):
Reconstruction Algorithm
◽
Correction Method
◽
Volume Effect
◽
Partial Volume Effect
◽
Partial Volume
◽
Partial Volume Effect Correction
◽
Spect Reconstruction
Download Full-text
Accuracy of partial volume effect correction in clinical molecular imaging of dopamine transporter using SPECT
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
◽
10.1016/j.nima.2006.10.236
◽
2007
◽
Vol 571
(1-2)
◽
pp. 173-176
◽
Cited By ~ 4
Author(s):
Marine Soret
◽
Jawad Alaoui
◽
Pierre M. Koulibaly
◽
Jacques Darcourt
◽
Irène Buvat
Keyword(s):
Molecular Imaging
◽
Dopamine Transporter
◽
Volume Effect
◽
Partial Volume Effect
◽
Partial Volume
◽
Partial Volume Effect Correction
Download Full-text
Fast and Accurate PET Preclinical Data Analysis: Segmentation and Partial Volume Effect Correction with no Anatomical priors
2008 IEEE Nuclear Science Symposium Conference Record
◽
10.1109/nssmic.2008.4774497
◽
2008
◽
Author(s):
Renaud Maroy
◽
Thomas Viel
◽
Raphael Boisgard
◽
Claude Comtat
◽
Regine Trebossen
◽
...
Keyword(s):
Data Analysis
◽
Volume Effect
◽
Partial Volume Effect
◽
Partial Volume
◽
Preclinical Data
◽
Partial Volume Effect Correction
◽
Anatomical Priors
Download Full-text
Minimizing the partial volume effect using the respiratory signal timing in the art of capturing images of the pet CT
Journal of Physics Conference Series
◽
10.1088/1742-6596/407/1/012021
◽
2012
◽
Vol 407
◽
pp. 012021
Author(s):
Welder Souza Goulão
◽
Araken dos Santos Werneck Rodrigues
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Signal Timing
◽
Partial Volume
◽
Pet Ct
◽
Respiratory Signal
Download Full-text
Impact of partial volume effect correction on cerebral β-amyloid imaging in APP-Swe mice using [18F]-florbetaben PET
NeuroImage
◽
10.1016/j.neuroimage.2013.09.017
◽
2014
◽
Vol 84
◽
pp. 843-853
◽
Cited By ~ 18
Author(s):
Matthias Brendel
◽
Andreas Delker
◽
Christina Rötzer
◽
Guido Böning
◽
Janette Carlsen
◽
...
Keyword(s):
Volume Effect
◽
Partial Volume Effect
◽
Amyloid Imaging
◽
Partial Volume
◽
Partial Volume Effect Correction
◽
Β Amyloid
Download Full-text
Usefulness of partial volume effect-corrected F-18 FDG PET/CT for predicting I-131 accumulation in the metastatic lymph nodes of patients with thyroid carcinoma
Annals of Nuclear Medicine
◽
10.1007/s12149-013-0767-8
◽
2013
◽
Vol 27
(10)
◽
pp. 873-879
◽
Cited By ~ 4
Author(s):
Yasuhiro Maruoka
◽
Koichiro Abe
◽
Shingo Baba
◽
Takuro Isoda
◽
Yoshiyuki Kitamura
◽
...
Keyword(s):
Thyroid Carcinoma
◽
Lymph Nodes
◽
Fdg Pet
◽
Volume Effect
◽
Partial Volume Effect
◽
Metastatic Lymph Nodes
◽
Partial Volume
◽
Metastatic Lymph
◽
Pet Ct
◽
Fdg Pet Ct
Download Full-text
Sign in / Sign up
Close
Export Citation Format
Close
Share Document
Close