scholarly journals Mitigation of conductor line galloping by a direct cable-connection to non-conductive composite power pylons

2018 ◽  
Vol 20 (6) ◽  
pp. 2268-2288 ◽  
Author(s):  
Mathias Kliem ◽  
Daniel Johansen ◽  
Jan Høgsberg
2018 ◽  
Vol 52 (26) ◽  
pp. 3601-3619 ◽  
Author(s):  
Mathias Kliem ◽  
Marvin Rüppel ◽  
Jan Høgsberg ◽  
Christian Berggreen ◽  
Sina Baier

This study aims to characterize the fibre direction dependent damping properties of non-conductive composite materials to be used in newly designed electrical power transmission pylons, on which the conducting cables will be directly connected. Thus, the composite structure can be designed both to insulate and to act as a damper to avoid for example conductor line galloping. In order to predict the damping of the composite materials, a comprehensive analysis on a representative unidirectional laminate was carried out. The fibre direction dependent damping analysis of glass and aramid reinforced epoxy and vinylester, partly reinforced with nanoclay or fibre-hybridized, was investigated using a Dynamic Mechanical Thermal Analysis and a Vibrating Beam Testing procedure for five different fibre orientations (0°, 30°, 45°, 60° and 90°). The focus was on damping behaviour evaluation at low temperatures (−20°C and 0°C) and low vibration frequencies (0.5 Hz, 1 Hz and 2 Hz), in order to represent the environmental conditions of vibrating conductor lines during. The prediction of the damping behaviour for coupon-level-specimens with three balanced laminates was successfully carried out with a maximal deviation of maximal 12.1%.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3615
Author(s):  
Adelaide Cerveira ◽  
Eduardo J. Solteiro Pires ◽  
José Baptista

Green energy has become a media issue due to climate changes, and consequently, the population has become more aware of pollution. Wind farms are an essential energy production alternative to fossil energy. The incentive to produce wind energy was a government policy some decades ago to decrease carbon emissions. In recent decades, wind farms were formed by a substation and a couple of turbines. Nowadays, wind farms are designed with hundreds of turbines requiring more than one substation. This paper formulates an integer linear programming model to design wind farms’ cable layout with several turbines. The proposed model obtains the optimal solution considering different cable types, infrastructure costs, and energy losses. An additional constraint was considered to limit the number of cables that cross a walkway, i.e., the number of connections between a set of wind turbines and the remaining wind farm. Furthermore, considering a discrete set of possible turbine locations, the model allows identifying those that should be present in the optimal solution, thereby addressing the optimal location of the substation(s) in the wind farm. The paper illustrates solutions and the associated costs of two wind farms, with up to 102 turbines and three substations in the optimal solution, selected among sixteen possible places. The optimal solutions are obtained in a short time.


2021 ◽  
Vol 27 ◽  
pp. 100819
Author(s):  
Zhiqiang Lai ◽  
Tao Zhao ◽  
Pengli Zhu ◽  
Jing Xiang ◽  
Dan Liu ◽  
...  

2012 ◽  
Vol 182-183 ◽  
pp. 254-258
Author(s):  
Zhong Li Zhao ◽  
Zun Li Mo ◽  
Zhong Yu Chen

Cellulose/Ag/polyaniline conductive composite with rather excellent electrical conductivity was heterogeneously synthesized in this paper. The UV-Vis analysis indicated that homogeneous nanoAg particles deposited on the surface of cellulose in the form of globe particles. They offered some electrons to polyaniline chains. This behavior resulted to the facts that more polyaniline embedded on cellulose and an integrated electrically conductive network formed. Consequently, the high electrical conductivity of the composite was observed. The value was 3.48 S/cm, which was higher two magnitudes than the electrical conductivity of cellulose/polyaniline composite (2.15×10-2S/cm), and even was higher than the electrical conductivity of pure polyaniline (0.142 S/cm). This paper provided a facile method for the preparation of cellulose/Ag/ polyaniline composite with favorable electrical conductivity.


Author(s):  
Ahmed A. Al-Ghamdi ◽  
Omar A. Al-Hartomy ◽  
Falleh R. Al-Solamy ◽  
Nikolay T. Dishovsky ◽  
Nikolay T. Atanasov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document