Assessment of Lisbon drinking water distribution network biofilm colonization and associated hazards

2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.

2021 ◽  
Vol 2139 (1) ◽  
pp. 012013
Author(s):  
C A Bonilla-Granados ◽  
N J Cely-Calixto ◽  
G A Carrillo Soto

Abstract Drinking-water distribution systems are generally designed with methodologies based on trial-and-error tests, which generate feasible results. However, these trials are not the most economical and reliable solution since they do not consider the optimization of the network. For the present work, the hydraulic model of the drinking water distribution network of San José de Cúcuta, Colombia, was optimized by applying the concept of resilience rate and minimum cost. The development of the work consisted of the hydraulic modeling of the physical components of the network in EPANET software, as well as the application of calculations of the connectivity coefficient and the unitary power of each section. With the data obtained from the modeling and calculations, the physical parameters were optimized, and the cost-benefit ratio was estimated. It was found that the current drinking water distribution system does not have a power surplus to overcome a system failure. The optimization increased the total energy surplus of the network (261%) and the resilience rate (585%). Also, the connectivity coefficient was improved with an average value of 0.95. The hydraulic optimization methodology applied resulted in a network resilient to system failures.


2009 ◽  
Vol 43 (20) ◽  
pp. 5005-5014 ◽  
Author(s):  
Jeffrey G. Szabo ◽  
Christopher A. Impellitteri ◽  
Shekar Govindaswamy ◽  
John S. Hall

2007 ◽  
Vol 2007 (1) ◽  
pp. 449-467
Author(s):  
Stacia L. Thompson ◽  
Elizabeth Casman ◽  
Paul Fischbeck ◽  
Mitchell J. Small ◽  
Jeanne M. VanBriesen

2009 ◽  
Vol 9 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Elise Corbi ◽  
Valérie Jacquemet ◽  
Alain Quendo ◽  
Francine Manciot ◽  
Adeline Lamy ◽  
...  

Lyon, France has the opportunity to distribute in abundance a groundwater resource with a good quality for drinking water. However, the length and the complexity of the distribution network can lead to consumer complaints in some areas of the water distribution system. In order to improve the organoleptic quality of distributed water, the water supplier wants to get a better understanding of potential taste and odour formation and to succeed in controlling it. Since 2006, activities have been taken with targeted analyses and sensory evaluation of water, taking into account both the consumers' private networks and the citywide distribution network. The first results were focused on the occurrence of bromophenols along the water distribution system, the understanding of the mechanisms of formation of such compounds, as well as their incidence on taste-and-odour events at the consumer's home.


Author(s):  
Pirjo-Liisa Rantanen ◽  
Ilkka Mellin ◽  
Minna Keinänen-Toivola ◽  
Merja Ahonen ◽  
Riku Vahala

We studied the seasonal variation of nitrite exposure in a drinking water distribution system (DWDS) with monochloramine disinfection in the Helsinki Metropolitan Area. In Finland, tap water is the main source of drinking water, and thus the nitrite in tap water increases nitrite exposure. Our data included both the obligatory monitoring and a sampling campaign data from a sampling campaign. Seasonality was evaluated by comparing a nitrite time series to temperature and by calculating the seasonal indices of the nitrite time series. The main drivers of nitrite seasonality were the temperature and the water age. We observed that with low water ages (median: 6.7 h) the highest nitrite exposure occurred during the summer months, and with higher water ages (median: 31 h) during the winter months. With the highest water age (190 h), nitrite concentrations were the lowest. At a low temperature, the high nitrite concentrations in the winter were caused by the decelerated ammonium oxidation. The dominant reaction at low water ages was ammonium oxidation into nitrite and, at high water ages, it was nitrite oxidation into nitrate. These results help to direct monitoring appropriately to gain exact knowledge of nitrite exposure. Also, possible future process changes and additional disinfection measures can be designed appropriately to minimize extra nitrite exposure.


Sign in / Sign up

Export Citation Format

Share Document