A general purpose centrifuge method for measuring particle-size distribution of air-filter inlet, outlet and catch dust samples is demonstrated. Treatment and analysis of data to determine air-cleaner performance based on size distribution is shown for two types of air filters, a louver and a glass-fiber media filter. The advantages and limitations of the method and interpretations of results associated with the application of these procedures for arriving at efficiency versus particle-size performance curves, and for predicting filter efficiency for any given dust are discussed.