Pancreatectomy With Artery En-bloc Resection for Pancreatic Neck/Body Cancer: A Single-arm Pilot Study

2021 ◽  
Vol 42 (1) ◽  
pp. 217-227
Author(s):  
KEN-ICHI OKADA ◽  
MANABU KAWAI ◽  
SEIKO HIRONO ◽  
SHINYA HAYAMI ◽  
MOTOKI MIYAZAWA ◽  
...  
2017 ◽  
Vol 15 (3) ◽  
pp. e311-e314 ◽  
Author(s):  
Zhensheng Zhang ◽  
Shuxiong Zeng ◽  
Junjie Zhao ◽  
Xin Lu ◽  
Weidong Xu ◽  
...  

2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Hiroaki Matsui ◽  
Naoto Tamai ◽  
Toshiki Futakuchi ◽  
Shunsuke Kamba ◽  
Akira Dobashi ◽  
...  

Abstract Background Endoscopic submucosal dissection (ESD) is technically difficult and requires considerable training. The authors have developed a multi-loop traction device (MLTD), a new traction device that offers easy attachment and detachment. We aimed to evaluate the utility of MLTD in ESD. Methods This ex vivo pilot study was a prospective, block-randomized, comparative study of a porcine stomach model. Twenty-four lesions were assigned to a group that undertook ESD using the MLTD (M-ESD group) and a group that undertook conventional ESD (C-ESD group) to compare the speed of submucosal dissection. In addition, the data of consecutive 10 patients with eleven gastric lesions was collected using electronic medical records to clarify the inaugural clinical outcomes of gastric ESD using MLTD. Results The median (interquartile range) speed of submucosal dissection in the M-ESD and C-ESD groups were 141.5 (60.9–177.6) mm2/min and 35.5 (20.8–52.3) mm2/min, respectively; submucosal dissection was significantly faster in the M-ESD group (p < 0.05). The rate of en bloc resection and R0 resection was 100% in both groups, and there were no perforation in either group. The MLTD attachment time was 2.5 ± 0.9 min and the MLTD extraction time was 1.0 ± 1.1 min. Clinical outcomes of MLTD in gastric ESD were almost the same as those of ex vivo pilot study. Conclusions MLTD increased the speed of submucosal dissection in ESD and was similarly effective when used by expert and trainee endoscopists without perforation. MLTD can potentially ensure a safer and faster ESD.


Endoscopy ◽  
2021 ◽  
Author(s):  
Hugo Uchima ◽  
Alberto Diez-Caballero ◽  
Jaume Capdevila ◽  
Mercé Rosinach ◽  
Alfredo Mata ◽  
...  

2021 ◽  
Vol 09 (03) ◽  
pp. E319-E323
Author(s):  
Madoka Takao ◽  
Yoshitaka Takegawa ◽  
Toshitatsu Takao ◽  
Hiroya Sakaguchi ◽  
Yoshiko Nakano ◽  
...  

Abstract Background and study aims Adequate mucosal elevation by submucosal injection is crucial for patient safety and efficiency during endoscopic submucosal dissection (ESD). This study aimed to evaluate the efficacy of fibrin glue (FG) as a long-lasting submucosal injection agent and to evaluate the technical feasibility of FG injection for ESD. Materials and methods To compare the capabilities of different agents in maintaining submucosal evaluation, we injected FG, hyaluronic acid solution, and normal saline into the porcine gastric specimen that was incised into approximately 5 × 5 cm squares. Then, we measured the height of submucosal elevations over time. Moreover, three hypothetical lesions from the resected porcine stomach underwent ESD with FG injection. Thereafter, we conducted macroscopic and histopathologic analyses. Results FG maintained the greatest submucosal elevation among all the injection agents. Three ESD procedures were performed with en bloc resection. Both macroscopic and histopathologic findings showed a thick FG clot on the ulcers. Conclusions The FG solution can be potentially used as an ESD submucosal injection agent in an in vitro model.


2021 ◽  
Vol 09 (05) ◽  
pp. E653-E658
Author(s):  
Tatsuma Nomura ◽  
Yoshikazu Hayashi ◽  
Takaaki Morikawa ◽  
Masahiro Okada ◽  
Hisashi Fukuda ◽  
...  

Abstract Background and study aims The pocket-creation method (PCM) facilitates dissection of the central part of a tumor. We previously developed the PCM with clip traction (PCM-CT) to facilitate opening the mucosal pocket, which otherwise could become cumbersome. In the present study, we aimed to examine the feasibility of PCM-CT for colorectal endoscopic submucosal dissection (ESD). Patients and methods PCM-CT was performed on 30 patients with early colorectal tumors from October 2019 to April 2020. PCM-CT allows efficient opening of the mucosal pocket by using the PCM to dissect the center of the lesion and then apply traction with a single clip after making a circumferential mucosal incision. Results The median specimen major axis length, ESD time, ESD speed, and en bloc resection rate were 48 mm, 84 minutes, 20 mm2/min, and 100 % (30/30), respectively. The success rates for the traction clip and median single-clip-traction time were 100 % (30/30) and 1.5 minutes, respectively. Conclusions Colorectal ESD using PCM-CT is a simple and promising method.


Sign in / Sign up

Export Citation Format

Share Document