scholarly journals First Reported Use of the Faxitron LOCalizer™ Radiofrequency Identification (RFID) System in Europe – A Feasibility Trial, Surgical Guide and Review for Non-palpable Breast Lesions

In Vivo ◽  
2019 ◽  
Vol 33 (5) ◽  
pp. 1559-1564 ◽  
Author(s):  
WOLFRAM MALTER ◽  
JOHANNES HOLTSCHMIDT ◽  
FABINSHY THANGARAJAH ◽  
PETER MALLMANN ◽  
BARBARA KRUG ◽  
...  
2019 ◽  
Vol 177 (3) ◽  
pp. 735-739 ◽  
Author(s):  
Caroline McGugin ◽  
Tara Spivey ◽  
Suzanne Coopey ◽  
Barbara Smith ◽  
Bridget Kelly ◽  
...  

2020 ◽  
pp. 155335062096785
Author(s):  
Carolyn M. Cullinane ◽  
James Byrne ◽  
Liga Akmenkalne ◽  
Donal P. O’ Leary ◽  
Alissa M. Connors ◽  
...  

Background. Breast screening has decreased morbidity and mortality due to detection of early, non-palpable breast cancers. One of the challenges of performing breast-conserving surgery on non-palpable breast tumours is accurate localization of the cancer. We aimed to perform a feasibility study to examine the outcomes associated with the introduction of a novel radiofrequency identification system (RFID) called LOCalizer as an alternative to traditional wire-guided localization. Methods. Data were prospectively collected on all patients undergoing breast-conserving surgery using the LOCalizer RFID system in a regional cancer centre between July 2019 and March 2020. Patients had a RFID tag placed preoperatively and underwent surgical removal of the tag with the index lesion guided by a handheld LOCalizer probe. The primary aim was successful placement and retrieval of the RFID tag. Re-excision rates, specimen size, specimen weight, cancer subtype and complication rate were all recorded. Results. Sixty-nine patients aged between 50 and 69 years had a LOCalizer tag inserted between July 2019 and March 2020. Of these, 6 (8.7%) were diagnostic and 63 (91.3%) were therapeutic. There was no migration of RFID tags, and all tags were retrieved with the index lesion. The overall re-excision of margin rate was 17.4% (12/69). All re-excision of margins was due to positive radial margins. The overall complication rate was 1.4% with one grade 1 Clavien-Dindo morbidity. Conclusion. The LOCalizer RFID is an effective and safe wire-free localization method for non-palpable breast lesions.


1997 ◽  
Vol 36 (08) ◽  
pp. 282-288 ◽  
Author(s):  
T. Atasever ◽  
A. Özdemir ◽  
I. Öznur ◽  
N. I. Karabacak ◽  
N. Gökçora ◽  
...  

Summary Aim: Our goal was to determine the clinical usefulness of TI-201 to identify breast cancer in patients with suspicious breast lesions on clinical examination, and/or abnormal radiologic (mammography and/or ultrasonography) findings. Methods: TI-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of TI-201. Visual and semiquantitative interpretation was performed. Results: Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. TI-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by TI-201 scintigraphy. The smallest mass lesion detected by TI-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. TI-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed TI-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated TI-201. TI-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by TI-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58 ± 0.38 (mean ± SD) and 1.48 ± 0.32 (p >0.05), 1.87 ± 0.65 and 1.34 ± 0.20 (p<0.05) respectively. The mean early and late L/N ratios of malignant and benign groups did not show statistical difference (p>0.05). Conclusion: Overall, TI-201 scintigraphy was the most specific of the three methods and yielded favourable results in palpable breast cancers, while it showed lower sensitivity in nonpalpable cancers and axillary metastases. Combined use of TI-201 scintigraphy with mammography and US seems to be useful in difficult cases, such as dense breasts and indeterminate breast lesions.


Author(s):  
Giulia Anna Follacchio ◽  
Francesco Monteleone ◽  
Maria Letizia Meggiorini ◽  
Maria Paola Nusiner ◽  
Carlo De Felice ◽  
...  

2003 ◽  
Vol 44 (3) ◽  
pp. 288-293
Author(s):  
B. Wilczek ◽  
P. Aspelin ◽  
B. Bone ◽  
A. Pegerfalk ◽  
J. Frisell ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document