Computer-aided diagnosis of gastrointestinal ulcer and hemorrhage using wireless capsule endoscopy: a systematic review and diagnostic test accuracy meta-analysis (Preprint)

2021 ◽  
Author(s):  
Chang Seok Bang ◽  
Jae Jun Lee ◽  
Gwang Ho Baik

BACKGROUND Interpretation of capsule endoscopy images or movies is operator-dependent and time-consuming. As a result, computer-aided diagnosis (CAD) has been applied to enhance the efficacy and accuracy of the review process. Two previous meta-analyses reported the diagnostic performance of CAD models for gastrointestinal ulcers or hemorrhage in capsule endoscopy. However, insufficient systematic reviews have been conducted, which cannot determine the real diagnostic validity of CAD models. OBJECTIVE To evaluate the diagnostic test accuracy of CAD models for gastrointestinal ulcers or hemorrhage using wireless capsule endoscopic images. METHODS We conducted core databases searching for studies based on CAD models for the diagnosis of ulcers or hemorrhage using capsule endoscopy and presenting data on diagnostic performance. Systematic review and diagnostic test accuracy meta-analysis were performed. RESULTS Overall, 39 studies were included. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of ulcers (or erosions) were .97 (95% confidence interval, .95–.98), .93 (.89–.95), .92 (.89–.94), and 138 (79–243), respectively. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of hemorrhage (or angioectasia) were .99 (.98–.99), .96 (.94–0.97), .97 (.95–.99), and 888 (343–2303), respectively. Subgroup analyses showed robust results. Meta-regression showed that published year, number of training images, and target disease (ulcers vs. erosions, hemorrhage vs. angioectasia) was found to be the source of heterogeneity. No publication bias was detected. CONCLUSIONS CAD models showed high performance for the optical diagnosis of gastrointestinal ulcer and hemorrhage in wireless capsule endoscopy. CLINICALTRIAL International Prospective Register of Systematic Reviews (PROSPERO): CRD42021253454 ; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=42021253454.

2020 ◽  
Vol 9 (4) ◽  
pp. 1133
Author(s):  
Hae Min Jeong ◽  
Chang Seok Bang ◽  
Jae Jun Lee ◽  
Gwang Ho Baik

Delta neutrophil index (DNI) is a novel diagnostic and prognostic biomarker of various infectious or inflammatory conditions. However, data on optimal measurement time are scarce, and no studies have evaluated the potential role of the DNI as a prognostic biomarker of gastrointestinal diseases with diagnostic test accuracy meta-analysis. Core databases were searched. The inclusion criteria were as follows: patients who have gastrointestinal diseases and DNI measurements presenting diagnostic indices for predicting the prognosis, including severity, surgical outcomes, and mortality from gastrointestinal diseases. We identified twelve studies for the systematic review and ten studies for the quantitative analysis. Pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of DNI at the initial admission date were 0.82 (95% confidence interval: 0.78–0.85), 0.75 (0.52–0.89), 0.76 (0.63–0.86), and 10 (3–35), respectively. Meta-regression showed no reasons for heterogeneity and publication bias was not detected. Fagan’s nomogram indicated that the posterior probability of ‘poor prognosis’ was 76% if the test was positive, and ‘no poor prognosis’ was 25% if the test was negative. The DNI can be considered as a reliable initial measurement biomarker for predicting prognosis in patients with gastrointestinal diseases,


2021 ◽  
Author(s):  
Chang Seok Bang ◽  
Jae Jun Lee ◽  
Gwang Ho Baik

BACKGROUND Wireless capsule endoscopy allows the identification of small intestinal protruded lesions, such as polyps, tumors, or venous structures. However, reading wireless capsule endoscopy images or movies is time-consuming, and minute lesions are easy to miss. Computer-aided diagnosis (CAD) has been applied to improve the efficacy of the reading process of wireless capsule endoscopy images or movies. However, there are no studies that systematically determine the performance of CAD models in diagnosing gastrointestinal protruded lesions. OBJECTIVE This aim of this study was to evaluate the diagnostic performance of CAD models for gastrointestinal protruded lesions using wireless capsule endoscopic images. METHODS Core databases were searched for studies based on CAD models for the diagnosis of gastrointestinal protruded lesions using wireless capsule endoscopy, and data on diagnostic performance were presented. A systematic review and diagnostic test accuracy meta-analysis were performed. RESULTS Twelve studies were included. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of protruded lesions were 0.95 (95% confidence interval, 0.93–0.97), 0.89 (0.84–0.92), 0.91 (0.86–0.94), and 74 (43–126), respectively. Subgroup analyses showed robust results. Meta-regression found no source of heterogeneity. Publication bias was not detected. CONCLUSIONS CAD models showed a high performance for the optical diagnosis of gastrointestinal protruded lesions based on wireless capsule endoscopy. CLINICALTRIAL Prospero registration number: id 276623


2021 ◽  
Author(s):  
Chang Seok Bang ◽  
Jae Jun Lee ◽  
Gwang Ho Baik

BACKGROUND The majority of colorectal polyps are diminutive and benign, especially for those in the rectosigmoid colon, and resecting these polyps is not cost-effective. Advancements in image-enhanced endoscopy has improved the optical prediction of histology in colorectal polyps. However, subjective interpretability and inter-/intra-observer variability prohibited the widespread implementation. Studies on computer-aided diagnosis (CAD) are increasing; however, their small sample size limits the statistical significance. OBJECTIVE to evaluate the diagnostic test accuracy of CAD models in predicting the histology of diminutive colorectal polyps using endoscopic images. METHODS Core databases were searched for studies based on endoscopic imaging using CAD models for the histologic diagnosis of diminutive colorectal polyps and presenting data on diagnostic performance. Systematic review and diagnostic test accuracy meta-analysis were performed. RESULTS Overall, 13 studies were included. The pooled area under the curve, sensitivity, specificity, and diagnostic odds ratio of CAD models for the diagnosis of diminutive colorectal polyps (adenomatous or neoplastic vs. nonadenomatous or nonneoplastic) were 0.96 (95% confidence interval, 0.93–0.97), 0.93 (0.91–0.95), 0.87 (0.76–0.93), and 87 (38–201), respectively. Meta-regression showed no heterogeneity, and no publication bias was detected. Subgroup analyses showed robust results. The negative predictive value of CAD models for the diagnosis of adenomatous polyp in the rectosigmoid colon was 0.96 (0.95–0.97), exceeding the threshold of the “diagnosis and leave” strategy. CONCLUSIONS CAD models show potential for the optical histologic diagnosis of diminutive colorectal polyps using endoscopic images.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Lei Xi ◽  
Chunqing Yang

AbstractObjectivesThe main aim of the present study was to assess the diagnostic value of alpha-l-fucosidase (AFU) for hepatocellular carcinoma (HCC).MethodsStudies that explored the diagnostic value of AFU in HCC were searched in EMBASE, SCI, and PUBMED. The sensitivity, specificity, and DOR about the accuracy of serum AFU in the diagnosis of HCC were pooled. The methodological quality of each article was evaluated with QUADAS-2 (quality assessment for studies of diagnostic accuracy 2). Receiver operating characteristic curves (ROC) analysis was performed. Statistical analysis was conducted by using Review Manager 5 and Open Meta-analyst.ResultsEighteen studies were selected in this study. The pooled estimates for AFU vs. α-fetoprotein (AFP) in the diagnosis of HCC in 18 studies were as follows: sensitivity of 0.7352 (0.6827, 0.7818) vs. 0.7501 (0.6725, 0.8144), and specificity of 0.7681 (0.6946, 0.8283) vs. 0.8208 (0.7586, 0.8697), diagnostic odds ratio (DOR) of 7.974(5.302, 11.993) vs. 13.401 (8.359, 21.483), area under the curve (AUC) of 0.7968 vs. 0.8451, respectively.ConclusionsAFU is comparable to AFP for the diagnosis of HCC.


Sign in / Sign up

Export Citation Format

Share Document