scholarly journals SCREENING OF NATURAL MODE AND EVALUATION OF BOUNDARY CONDITION FOR DYNAMIC ANALYSIS OF ARCH DAM

Author(s):  
Taiji MAZDA ◽  
Nobuyuki OKUMA ◽  
Hiroki AKINAGA
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Vahid Lotfi ◽  
Ali Lotfi

Purpose Subsequently, the response of idealized Morrow Point arch dam is studied due to stream, vertical and cross-stream ground motions for reservoir bottom/sidewalls conditions of both fully reflective and absorptive. For each combination, different orders of Hagstrom–Warburton (HW) condition are evaluated from accuracy point of view by comparing them against exact solutions. It should be emphasized that normalized length of reservoir near-field region is taken as a very low value of L/H = 0.2 during this process which makes it a very challenging test for any kind of truncation boundary condition. Design/methodology/approach In present study, dynamic analysis of concrete arch dam-reservoir systems is formulated by FE-(FE-TE) approach [i.e. finite element-(finite element-truncation element)]. In this technique, dam and reservoir are discretized by solid and fluid finite elements. Moreover, the HW high-order condition imposed at the reservoir truncation boundary. This task is formulated by employing a truncation element at that boundary. It is emphasized that reservoir far-field is excluded from the discretized model. The formulation is initially explained in details. Findings The trend in gaining accuracy with increase in order of HW condition were basically the same for all three types of excitations under both full reflective and absorptive reservoir bottom/sidewalls conditions. The only exception was for cross-stream excitation response which was showing less accurate results near the first major peak for moderate orders of HW (e.g. O3-2) in comparison to what was observed for responses due to symmetric excitations (stream and vertical). This is mainly attributed to the selection of evanescent-type parameters of HW condition which is based on the first symmetric mode of reservoir. However, it is noted that error diminishes even for cross-stream excitation as order increases. High orders of HW condition, such as O5-5 considered herein, generate highly accurate responses for all three possible excitations under both types of full reflective and absorptive reservoir bottom/sidewalls conditions. It is such that responses are hardly distinguishable from corresponding exact responses. This reveals that proposed FE-(FE-TE) analysis technique based on HW condition is quite successful, and one may fully rely on that for accurate and efficient analysis of concrete arch dam-reservoir systems. Originality/value Dynamic analysis of concrete arch dam-reservoir system is formulated by new method. HW high-order condition is applied for a very low and challenging reservoir length. Different orders are evaluated against exact solution with excellent agreement. Generalized matrices of truncation element are derived for FEM programmers. The method is discussed for all types of excitation and reservoir base conditions.


2012 ◽  
Vol 594-597 ◽  
pp. 904-907 ◽  
Author(s):  
Jun Xia ◽  
Z. Shen ◽  
Bin Chen

The finite element formulations of steel-concrete composite (SCC) beams considering interlayer slip with end shear restraint were established. Free vibrations of SCC beams and frame structures under different slip boundary conditions were examined. The influences of the shear connection stiffness and the slip boundary condition on dynamic characteristics were analyzed. It is shown that the low order 8-DOF element may exhibit slip locking phenomenon in free vibration analysis for very stiff connection. The free vibration frequencies of composite beams and frame structures increase with the shear connection stiffness increasing. Besides, it is found that the natural vibration properties of SCC frame structures are significantly affected by the slip boundary condition, and it should be suitably imposed on all composite beams in dynamic analysis.


Author(s):  
M. D. Yang ◽  
B. Teng

A time-domain simulation method is developed for the coupled dynamic analysis of a spar platform with mooring lines. For the hydrodynamic loads, a time domain second order method is developed. In this approach, Taylor series expansions are applied to the body surface boundary condition and the free surface boundary condition, and Stokes perturbation procedure is then used to establish corresponding boundary value problems with time-independent boundaries. A higher order boundary element method is developed to calculate the velocity potential of the resulting flow field at each time step. The free-surface boundary condition is satisfied to the second order by 4th order Adams-Bashforth-Moultn method. An artificial damping layer is adopted on the free surface to avoid the wave reflection. For the mooring-line dynamics, a geometrically nonlinear finite element method using isoparametric cable element based on the total Lagrangian formulation is developed. In the coupled dynamic analysis, the motion equation for the hull and dynamic equations for mooring lines are solved simultaneously using Newmark method. Numerical results including motions and tensions in the mooring lines are presented.


2015 ◽  
Author(s):  
Qiang Mao ◽  
John Devitis ◽  
Matteo Mazzotti ◽  
Ivan Bartoli ◽  
Franklin Moon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document