Diabeloop DBLG1 Closed-Loop System Enables Patients With Type 1 Diabetes to Significantly Improve Their Glycemic Control in Real-Life Situations Without Serious Adverse Events: 6-Month Follow-up

Diabetes Care ◽  
2021 ◽  
Vol 44 (3) ◽  
pp. 844-846
Author(s):  
Coralie Amadou ◽  
Sylvia Franc ◽  
Pierre-Yves Benhamou ◽  
Sandrine Lablanche ◽  
Erik Huneker ◽  
...  
2021 ◽  
Author(s):  
Coralie Amadou ◽  
Sylvia Franc ◽  
Pierre-Yves Benhamou ◽  
Sandrine Lablanche ◽  
Erik Huneker ◽  
...  

<b>OBJECTIVE </b> <p>To analyze safety and efficacy of the DBLG1 hybrid closed-loop artificial pancreas system in patients with Type 1 Diabetes in real life conditions. </p> <p> </p> <p><b>METHODS</b></p> <p>Following a one-week run-in period with usual pump, 25 patients were provided with the commercial DBLG1 system. We present the results of Time-in-Range and HbA1c over a 6-month period.</p> <p><b> </b></p> <p><b>RESULTS</b></p> <p>The mean (SD;range) age of patients was 43 years (13.8; 25-72). At baseline, mean HbA1c and TIR 70-180mg/dL were respectively 7.9% (0.93; 5.6- 8.5) [63mmol/mol (10; 38-69)] and 53% (16.4;21-85). One patient stopped using the system after 2 months. At 6-month, mean HbA1c decreased to 7.1% [54mmol/mol] (p<0.001) and TIR 70-180mg/dL increased to 69.7% (p<0.0001). TIR<70mg/dL decreased from 2.4 to 1.3% (p=0.03). TIR<54mg/dL decreased from 0.32 to 0.24% (p=0.42). No serious adverse event was reported during the study. </p> <p> </p> <p><b>CONCLUSION</b></p> <p>The DBLG1 System confirms its ability to significantly improve glycemic control in real life conditions, without serious adverse events. </p>


2021 ◽  
Author(s):  
Coralie Amadou ◽  
Sylvia Franc ◽  
Pierre-Yves Benhamou ◽  
Sandrine Lablanche ◽  
Erik Huneker ◽  
...  

<b>OBJECTIVE </b> <p>To analyze safety and efficacy of the DBLG1 hybrid closed-loop artificial pancreas system in patients with Type 1 Diabetes in real life conditions. </p> <p> </p> <p><b>METHODS</b></p> <p>Following a one-week run-in period with usual pump, 25 patients were provided with the commercial DBLG1 system. We present the results of Time-in-Range and HbA1c over a 6-month period.</p> <p><b> </b></p> <p><b>RESULTS</b></p> <p>The mean (SD;range) age of patients was 43 years (13.8; 25-72). At baseline, mean HbA1c and TIR 70-180mg/dL were respectively 7.9% (0.93; 5.6- 8.5) [63mmol/mol (10; 38-69)] and 53% (16.4;21-85). One patient stopped using the system after 2 months. At 6-month, mean HbA1c decreased to 7.1% [54mmol/mol] (p<0.001) and TIR 70-180mg/dL increased to 69.7% (p<0.0001). TIR<70mg/dL decreased from 2.4 to 1.3% (p=0.03). TIR<54mg/dL decreased from 0.32 to 0.24% (p=0.42). No serious adverse event was reported during the study. </p> <p> </p> <p><b>CONCLUSION</b></p> <p>The DBLG1 System confirms its ability to significantly improve glycemic control in real life conditions, without serious adverse events. </p>


Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 1066-P
Author(s):  
HALIS K. AKTURK ◽  
DOMINIQUE A. GIORDANO ◽  
HAL JOSEPH ◽  
SATISH K. GARG ◽  
JANET K. SNELL-BERGEON

Diabetes ◽  
2021 ◽  
Vol 70 (Supplement 1) ◽  
pp. 102-LB
Author(s):  
ADRIAN E. PROIETTI ◽  
MARCIAL A. ANGÓS ◽  
ALEJANDRO DAIN ◽  
MARIELA I. ECHENIQUE ◽  
MARÍA L. KABAKIAN ◽  
...  

Diabetes Care ◽  
2020 ◽  
Vol 43 (12) ◽  
pp. 3102-3105
Author(s):  
Vera Lehmann ◽  
Thomas Zueger ◽  
Anna Zeder ◽  
Sam Scott ◽  
Lia Bally ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document