Effect of Different Adhesion Strategies on Bond Strength of Resin Composite to Composite-dentin Complex

2013 ◽  
Vol 38 (1) ◽  
pp. 63-72 ◽  
Author(s):  
M Özcan ◽  
G Pekkan

ABSTRACT Service life of discolored and abraded resin composite restorations could be prolonged by repair or relayering actions. Composite-composite adhesion can be achieved successfully using some surface conditioning methods, but the most effective adhesion protocol for relayering is not known when the composite restorations are surrounded with dentin. This study evaluated the effect of three adhesion strategies on the bond strength of resin composite to the composite-dentin complex. Intact maxillary central incisors (N=72, n=8 per subgroup) were collected and the coronal parts of the teeth were embedded in autopolymerized poly(methyl tfr54methacrylate) surrounded by a polyvinyl chloride cylinder. Cylindrical cavities (diameter: 2.6 mm; depth: 2 mm) were opened in the middle of the labial surfaces of the teeth using a standard diamond bur, and the specimens were randomly divided into three groups. Two types of resin composite, namely microhybrid (Quadrant Anterior Shine; AS) and nanohybrid (Grandio; G), were photo-polymerized incrementally in the cavities according to each manufacturer's recommendations. The composite-enamel surfaces were ground finished to 1200-grit silicone carbide paper until the dentin was exposed. The surfaces of the substrate composites and the surrounding dentin were conditioned according to one of the following adhesion protocols: protocol 1: acid-etching (dentin) + silica coating (composite) + silanization (composite) + primer (dentin) + bonding agent (dentin + composite); protocol 2: silica coating (composite) + acid-etching (dentin) + silanization (composite) + primer (dentin) + bonding agent (dentin + composite); and protocol 3: acid-etching (dentin) + primer (dentin) + silanization (composite) + bonding agent (dentin + composite). Applied primer and bonding agents were the corresponding materials of the composite manufacturer. Silica coating (CoJet sand, 30 μm) was achieved using a chairside air-abrasion device (distance: 10 mm; duration: four seconds in circular motion). After conditioning protocols, the repair resin was adhered to the substrate surfaces using transparent polyethylene molds (diameter: 3.6 mm) incrementally and photo-polymerized. The substrate-adherend combinations were as follows: AS-AS, G-G, AS-G. Shear force was applied to the adhesive interface in a Universal Testing Machine (crosshead speed: 1 mm/min). The types of failures were further evaluated and categorized as follows: 1) cohesive in the composite substrate and 2) adhesive at the interface. Bond strength values (MPa) were statistically analyzed using two-way analysis of variance and least significant difference post hoc tests (α=0.05). Significant effects of the adhesion strategy (p=0.006) and the composite type (p=0.000) were found. Interaction terms were not significant (p=0.292). Regardless of the substrate-adherend combination, protocol 1 (17–22 MPa) showed significantly higher results than did protocols 2 (15–17 MPa) and 3 (11–17 MPa) (p=0.028, p=0.002, respectively). The highest results were obtained from the G-G combination after all three protocols (17–22 MPa). The incidence of cohesive failures was more common when the substrate and the adherend were the same composite type (AS-AS: 87.5%, 87.5%, 75%; G-G: 100%, 75%, 50% for protocols 1, 2, and 3, respectively). When substrate and adherend were used interchangeably, adhesive failures were more frequent (25%, 50%, and 100% for protocol 1, 2, and 3, respectively). When the substrate and the adherend are of the same type, greater repair strength could be expected. In the repair of composites next to the dentin, depending on the composite type, conditioning the composite with silica coating and silanization after etching the dentin adds to the repair strength compared to the results obtained with silane application only.

2013 ◽  
Vol 63 (1) ◽  
pp. 66-72 ◽  
Author(s):  
Ewa Błaszczeć-Kubiak ◽  
Agnieszka Pacyk ◽  
Barbara Łapińska ◽  
Grzegorz Sokołowski ◽  
Jerzy Sokołowski

2011 ◽  
Vol 36 (5) ◽  
pp. 563-566 ◽  
Author(s):  
M Özcan ◽  
E Salihoğlu-Yener

SUMMARY This clinical report describes a repair protocol for cusp fracture of a failed amalgam-dentin complex. A maxillary right first premolar with an amalgam restoration presented a buccal cusp fracture. Chairside repair has been undertaken by conditioning the existing amalgam restoration with silica coating (30 μm CoJet®-Sand), phosphoric acid etching the beveled enamel surface, priming dentin, and application of a bonding agent on both enamel and dentin. Thereafter, the amalgam was silanized (ESPE®-Sil), and opaque resin was applied and polymerized to mask the amalgam. The fractured buccal cusp was modeled using resin composite (Clearfil Photo Posterior) and photo-polymerized. Finally, the amalgam was refinished and refurbished and the composite was finished and polished.


2000 ◽  
Vol 14 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Jorge Saldivar BOCANGEL ◽  
Alex O. E. KRAUL ◽  
Absalon G. VARGAS ◽  
Flávio Fernando DEMARCO ◽  
Edmir MATSON

The purpose of the present study was to evaluate the influence of different disinfectant solutions on the tensile bond strength of a fourth generation dentin bonding agent. Forty non carious human molars were selected. Teeth were embedded in acrylic resin and ground until the exposure of a flat superficial dentin surface. Teeth were randomly divided in 4 groups and treated as follows: Group 1 - 2.5% NaOCl for 40 seconds; Group 2 - 2% chlorhexidine for 40 seconds; Group 3 - 1.23% acidulated fluoride for 4 minutes; and Group 4 - control (without disinfectant solution). Following treatments, Scotchbond Multipurpose Plus® (3M) was used according to the manufacturer’s instructions. After that, the test specimens were built with composite resin (Z100®-3M), using a standard Teflon matrix. The specimens were stored in distilled water for 24 hours at a temperature of 37ºC. The tensile strength test was performed using a Mini Instrom testing machine. The mean values obtained for each group, in MPa, were: Group 1 - 7.37 (± 2.51); Group 2 - 11.25 (± 4.65); Group 3 - 9.80 (± 3.11); and Group 4 - 10.96 (± 3.37). The results were submitted to statistical analysis using the ANOVA test, and no statistical significant differences among the groups were found. It can be concluded that the different disinfectant substances used in this research do not adversely affect dentin adhesion.


2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Robert Dalby ◽  
Ayman Ellakwa ◽  
Brian Millar ◽  
F. Elizabeth Martin

Objectives. To examine the effect of immediate dentin sealing (IDS), with dentin bonding agents (DBAs) applied to freshly cut dentin, on the shear bond strength of etched pressed ceramic luted to dentin with RelyX Unicem (RXU) cement.Method. Eighty extracted noncarious third molars were ground flat to expose the occlusal dentin surfaces. The teeth were randomly allocated to five groups (A to E) of sixteen teeth each. Groups A to D were allocated a dentin bonding agent (Optibond FL, One Coat Bond, Single Bond, or Go!) that was applied to the dentin surface to mimic the clinical procedure of IDS. These specimen groups then had etched glass ceramic discs (Authentic) luted to the sealed dentin surface using RXU. Group E (control) had etched glass ceramic discs luted to the dentin surface (without a dentin bonding agent) using RXU following the manufacturer’s instructions. All specimens were stored for one week in distilled water at room temperature and then shear stressed at a constant cross-head speed of 1 mm per minute until failure. Statistical analysis was performed by ANOVA followed by post hoc Tukey HSD method () applied for multiple paired comparisons.Results. The shear bond strength results for group A to E ranged from to  MPa. One-way ANOVA demonstrated a difference () between the groups tested and the Tukey HSD demonstrated a significant () difference between the shear bond strength (SBS) of Optibond FL (Group A) and Go! (Group D). There was no statistical difference () in the SBS between the test groups (A–D) or the control (group E).Conclusion. IDS using the dentin bonding agents tested does not statistically () affect the shear bond strength of etched pressed ceramic luted to dentin with RXU when compared to the control.


2012 ◽  
Vol 13 (5) ◽  
pp. 632-636 ◽  
Author(s):  
Pooran Samimi ◽  
Mehrdad Barekatain ◽  
Samaneh Alaei

ABSTRACT Introduction The success of bonded restorations depends on effective bonding between restorative materials and tooth structure, and it prevents microleakage. New dentin bonding systems have been introduced which promotes this concept. The aim of this study was to compare the amount of microleakage between ‘single bond’ vs ‘Prompt L-Pop’ during different time periods. Materials and methods In this clinical trial study, 60 nonretentive class five cavities were prepared on buccal surfaces of human premolars which were scheduled to be removed for orthodontic purposes. The cavities were restored using two different bonding agents; fifth generation (Single Bond) and sixth generation (Prompt L-Pop) and then filled with resin composite (Filtek Z-250). The samples in both groups were extracted after placing the restoration in three periods of time: Immediately, 1 week and 6 months postplacement. Specimens were sealed with two layers of nail varnish except for 1 mm around restoration and immersed in a silver nitrate solution for 24 hours. The teeth were then sectioned longitudinally and the degree of microleakage was determined by stereomicroscope based on standard usual criteria. Results Single bond showed more leakage at dentin margin than enamel margin in all three extraction periods and differences were significant among three groups (p < 0.05). In samples which were restored with Prompt L-Pop only in groups of 6 months there were significant differences between enamel and dentin margins. At enamel margin there were no significant differences between microleakage of groups according to the passage of time (p > 0.05). Conclusion The results of this study using two different bonding systems, indicate that adhesion to enamel was more valuable than dentin and perhaps systems that include self-etching primers are less sensitive to remaining moisture on dentin and they are less affected during different time periods. How to cite this article Samimi P, Barekatain M, Alaei S. Comparison of Microleakage of Composite Restorations using Fifth and Sixth Generation Dentin Bonding Agent: An in vivo Study. J Contemp Dent Pract 2012;13(5):632-636.