scholarly journals Evaluation of Medium Voltage Distribution Network with/without Distributed Generation using ATP Software

Author(s):  
J.O. Rezende ◽  
L.M. Peres ◽  
G. C. Guimarães ◽  
A. J. de Moraes ◽  
M. A. Tamashiro
Author(s):  
Massimo Cresta ◽  
Fabio Massimo Gatta ◽  
Alberto Geri ◽  
Regina Lamedica ◽  
Stefano Lauria ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5717
Author(s):  
Oscar Danilo Montoya ◽  
Walter Gil-González ◽  
Andrés Arias-Londoño ◽  
Arul Rajagopalan ◽  
Jesus C. Hernández

This paper addresses the voltage stability margin calculation in medium-voltage distribution networks in the context of exact mathematical modeling. This margin calculation is performed with a second-order cone (SOCP) reformulation of the classical nonlinear non-convex optimal power flow problems. The main idea around the SOCP approximation is to guarantee the global optimal solution via convex optimization, considering as the objective function the λ-coefficient associated with the maximum possible increment of the load consumption at all the nodes. Different simulation cases are considered in one test feeder, described as follows: (i) the distribution network without penetration of distributed generation; (ii) the distribution network with penetration of distributed generation; and (iii) the distribution grid with capacitive compensation. Numerical results in the test system demonstrated the effectiveness of the proposed SOCP approximation to determine the λ-coefficient. In addition, the proposed approximation is compared with nonlinear tools available in the literature. All the simulations are carried out in the MATLAB software with the CVX package and the Gurobi solver.


2016 ◽  
Vol 15 (1) ◽  
pp. 27
Author(s):  
I Wayan Agus Teja Baskara ◽  
I G Dyana Arjana ◽  
I W Rinas

Ground wire is one of the lighning protection instrument used in medium voltage distribution network with the intention to reduce interference due to lightning strikes. On the feeder Serangan the ground wire put 4 – 5 wicket. To know effective gap of ground wire is put on the feeder Serangan then used effectiveness ground wire parameters and total of disorder by lightning strikes directly or indirectly. From the analysis is obtained the effective gap on scenario 4 by 3 – 4 wicket. Choosing scenario 4 is as effective gap because seen by economic aspect, as longest gap point put of ground wire then the cost needed to use material and the installation of ground wire will be cheaper.  DOI: 10.24843/MITE.1501.05