scholarly journals The Characteristics of Current and Resistance of A Lead-Acid Battery Recharger using High Frequency Pulse

Author(s):  
Min Ho Kim et al., Min Ho Kim et al., ◽  
2021 ◽  
Vol 4 (1) ◽  
pp. 44-52
Author(s):  
Anthony Chibuike Ohajianya ◽  
Emmanuel C. Mbamala ◽  
Chijioke M. Amakom ◽  
Chidi E. Akujor

The major cause of deterioration in lead-acid batteries is sulfation. There are patents on the use of high-frequency pulse desulfators to desulfate lead-acid batteries. Also, many products available in the market worldwide claim to use this technique to effectively desulfate lead-acid batteries that deteriorate due to sulfation. But there are little or no systematic studies to evaluate the performance of these products to know whether they do what their manufacturers claim. This research, therefore, aims at empirically evaluating one of such products. Four fully charged 100 Ampere-hour Valve Regulated Lead-Acid Gel batteries were discharged with an electronic-load battery discharger to ascertain their capacities. Thereafter, a high-frequency pulse desulfator was connected to desulfate the battery bank consisting of the four batteries. The battery bank was connected to be charged at the same time by a photovoltaic system. The desulfation experiment lasted for ten weeks but the batteries were tested to know their capacities after two, six, and ten weeks. The results show that the desulfation device works in desulfating lead-acid batteries as there are different degrees of improvement on the capacity of all the batteries. The percentage improvement in the capacity of the batteries is 89.5%, 75.9%, 1.6% and 1.4%, for batteries 1, 2, 3 and 4, respectively.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Hung-I. Hsieh ◽  
Sheng-Fang Shih ◽  
Jen-Hao Hsieh ◽  
Chi-Hao Wang

A photovoltaic pulse charger (PV-PC) using high-frequency pulse train for charging lead-acid battery (LAB) is proposed not only to explore the charging behavior with maximum power point tracking (MPPT) but also to delay sulfating crystallization on the electrode pores of the LAB to prolong the battery life, which is achieved due to a brief pulse break between adjacent pulses that refreshes the discharging of LAB. Maximum energy transfer between the PV module and a boost current converter (BCC) is modeled to maximize the charging energy for LAB under different solar insolation. A duty control, guided by a power-increment-aided incremental-conductance MPPT (PI-INC MPPT), is implemented to the BCC that operates at maximum power point (MPP) against the random insolation. A 250 W PV-PC system for charging a four-in-series LAB (48 Vdc) is examined. The charging behavior of the PV-PC system in comparison with that of CC-CV charger is studied. Four scenarios of charging statuses of PV-BC system under different solar insolation changes are investigated and compared with that using INC MPPT.


2006 ◽  
Vol 158 (2) ◽  
pp. 1012-1018 ◽  
Author(s):  
F. Huet ◽  
R.P. Nogueira ◽  
P. Lailler ◽  
L. Torcheux

2013 ◽  
Vol 12 (11) ◽  
pp. 2175-2182 ◽  
Author(s):  
Jiakuan Yang ◽  
Xinfeng Zhu ◽  
Lei Li ◽  
Jianwen Liu ◽  
Ramachandran Vasant Kumar

1995 ◽  
Vol 30 (2) ◽  
pp. 299-304 ◽  
Author(s):  
Cameron D. Skinner ◽  
Eric D. Salin

Abstract Soil lead levels were determined on and around a former battery manufacturing site. Lead concentrations ranging from 120 ppm to 5.1’ were found. The highest concentrations were found close to the factory site. When it was possible to obtain samples over a continuous depth range, it was found that lead concentration decreased with depth and that it increased above underground foundations.


Sign in / Sign up

Export Citation Format

Share Document