One of the most effective methods for descaling hot-rolled steel products is performed using highpressure flat jet nozzles. These descaling nozzles are arranged in rows in hot rolling mills and areset in such a way that each adjoining pair of nozzles creates an overlapping area of water jet streams.Good homogeneity of the pressure distribution over the width of the hot-rolled plate is often used as anindicator of quality of the homogeneity of descaling. The presented laboratory measurements examineone pair of adjoining nozzles with a particular focus on the pressure distribution in the overlappingarea. This paper deals with one particular setting of a pair of descaling nozzles with zero offset anglesfor the jet streams. A measured pressure distribution and an outcome of an erosion test on an aluminumplate are presented and discussed. The erosion test shows that spots with higher pressures do notnecessarily result in a higher amount of removed material during an erosion test. The erosion test differs from the expected outcome in such a way that a detailed discussion of this phenomenon is outlined with possible explanations.