Design & Testing of Portable Air Conditioner for Trail Production

Author(s):  
G Naveen ◽  
◽  
Suresh Akella ◽  
K Sainath ◽  
◽  
...  
Keyword(s):  
Author(s):  
Syed Ahmed Alisha ◽  
◽  
N Vinod Kumar Reddy ◽  
Akhil Reddy ◽  
Sampath Kumar ◽  
...  

Author(s):  
D. T. Chen ◽  
J. Y. Lin ◽  
Y. K. Chuah ◽  
L. J. Fang

Author(s):  
Renato Arruda de Oliveira ◽  
Luiz Machado ◽  
Willian Moreira Duarte

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


2015 ◽  
Vol 9 (1) ◽  
pp. 135-140
Author(s):  
Dong Zhi-Ming ◽  
Guo Li-Xia ◽  
Chang Ji-Bin ◽  
Zhou Xue-Bin

Aiming to compare the cooling effect, two types of solar-powered semiconductor air-conditioning devices were designed in different structures. According to the cooling load in an experimental room, the solar panels and battery capacity were determined for the development of a test system. In the same working condition, a comparison test was carried out to examine the cooling performance. Experimental results showed that the design of dual water-cooled cooling unit presented a higher ratio of energy efficiency, with its maximum value of 1.08. By observing the experimental data of the prototype, its comparative economic evaluation results indicated that the annualized cost of solar semiconductor airconditioning was app. 2.7 times that of air-conditioning made from an ordinary compressor.


Sign in / Sign up

Export Citation Format

Share Document