Heat capacity model for a mixture containing a phase change material

1998 ◽  
Author(s):  
W. Bowman ◽  
David Brown
2014 ◽  
Vol 136 (6) ◽  
Author(s):  
Hessam Taherian ◽  
Jorge L. Alvarado ◽  
Kalpana Tumuluri ◽  
Curt Thies ◽  
Chan-Hyun Park

Microencapsulated phase change material (MPCM) slurry is consisted of a base fluid in which MPCM is dispersed. Due to apparent high heat capacity associated with phase change process, MPCM slurry can be used as a viable heat transfer fluid (HTF) for turbulent flow conditions. Heat transfer and fluid flow properties of the slurry in turbulent flow (3000 < Re < 6000) were determined experimentally. Dynamic viscosity of the MPCM slurry was measured at different temperatures close to the melting point of the material (20–30 °C). Pressure drop measurements under turbulent flow conditions were recorded for 6 MPCM samples at various concentrations. The pressure drop of the MPCM slurry was comparable to that of water despite the higher viscosity of the slurry. The effect of heat flux, MPCM mass concentration, flow rate and the type of phase change material was investigated. The effective heat capacity of slurry at the location where phase change occurs was found to be considerably higher than that of water. A nondimensional Nusselt number correlation was proposed in order to facilitate design of heat transfer loops with MPCM slurries as working fluid.


Author(s):  
Zeng-Bo Ke ◽  
You-Ying Di ◽  
Xin-Hui Fan ◽  
Feng-Ying Chen ◽  
Zhen-Fei Gao ◽  
...  

Author(s):  
Miroslaw Liszka ◽  
Aleksandr Fridlyand ◽  
Ambalavanan Jayaraman ◽  
Michael Bonnema ◽  
Chakravarthy Sishtla

Abstract This work is a continuation of a previous study (IMECE2019-11449) which sought to explore the feasibility and means of successfully modeling the hydrogen fast filling process of cylinders lined with phase change material (PCM) entirely in CFD software. The first focus of this work was to address the simplistic approach of how the liner temperature was modelled in the previous study. Previously, the entire liner was assigned a single temperature which was obtained and updated through the lumped heat capacity method. This meant that the hotter gas at the end of the cylinder opposite the inlet was in contact with a liner at a temperature lower than could realistically be expected. This was remedied by splitting the liner into four sections. Two sections were used for the curved portions at each end of the cylinder, and the straight wall section was split into two. Each section had its temperature independently calculated through the lumped heat capacity method. A temperature difference on the order of a ten degrees Celsius was observed between the different sections of the liner prior to latent heating beginning. The mass averaged temperature of the hydrogen inside the cylinder obtained with the sectioned wall case matched that obtained with the single wall temperature almost exactly, less than a degree difference. Despite the unexpected findings of the average hydrogen temperature not changing much when the wall is split into sections, this approach was still taken with all the cases completed in this study. The liner could be split into a greater amount of sections than four, but this was considered unnecessary due to the findings regarding the overall hydrogen temperature. Four sections were considered adequate and used to model the temperature gradient along the wall or liner. The effect of gravity on the filling process was also explored based on the orientation of the cylinder. This required completing three-dimensional simulations to accurately simulate buoyancy driven flow in horizontally mounted cylinders. All the simulations were completed with ANSYS Fluent 2019 R1 without the use of additional software to handle the heat transfer involving the PCM. All simulations were completed with the coupled pressure-based solver and K-Omega SST turbulence model. The gas properties were obtained from tables generated from NIST properties (REFPROP) available within ANSYS Fluent to limit the amount of error in the accumulated mass within the cylinder due to inaccurate gas properties. The initial conditions for the gas and liner temperatures were 25°C and 100 bar for the gas pressure. A constant mass flow rate of 0.02174 kg/s at a temperature 0°C were used as the initial conditions for the inlet hydrogen gas.


2011 ◽  
Vol 214 ◽  
pp. 662-667
Author(s):  
Yan Lai Zhang ◽  
Zhong Hao Rao ◽  
Jie Fei Xie ◽  
Shuang Feng Wang

Heat storage experiment by natural convection in rectangular tanks heated from below has been conducted with fluidity slurry composed of microencapsulated phase change material (PCM). The slurry shows a peak value in the specific heat capacity with latent heat at the temperature of about T = 31 °C. The effects of the heating wall temperature TH, the PCM mass concentration Cm of the PCM slurry and the height H of the tank on heat storage are revealed, respectively.


2018 ◽  
Vol 49 (6) ◽  
pp. 509-528 ◽  
Author(s):  
Orawan Aumporn ◽  
Belkacem Zeghmati ◽  
Xavier Chesneau ◽  
Serm Janjai