PULMONARY VEIN ISOLATION, USING RADIOFREQUENCY ABLATION (CLOSE-PROTOCOL) AND CRYOBALLOON ABLATION IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION

2019 ◽  
Vol 14 (3) ◽  
pp. 13-21
Author(s):  
Yu.L. Shevchenko ◽  
S.A. Bashilov ◽  
A.V. Sveshnikov ◽  
A.S. Vorobiev ◽  
V.G. Gudimovich ◽  
...  
2016 ◽  
Vol 02 (02) ◽  
pp. 55
Author(s):  
Karl-Heinz Kuck ◽  
Michael Schlüter ◽  
◽  

Whilst radiofrequency ablation is widely considered the “gold standard” for pulmonary-vein isolation, cryoballoon ablation is considered easier to perform. The aim of the randomised, multicentre FIRE AND ICE trial was to demonstrate, in patients with paroxysmal atrial fibrillation, the non-inferiority of cryoballoon ablation with respect to the time to a first documented clinical failure within 1 year outside a 90-day “blanking period” after the index ablation. This editorial gives an overview of the trial and its findings.


2020 ◽  
Vol 13 (9) ◽  
Author(s):  
Zak Loring ◽  
DaJuanicia N. Holmes ◽  
Roland A. Matsouaka ◽  
Anne B. Curtis ◽  
John D. Day ◽  
...  

Background: Catheter ablation is an increasingly used treatment for symptomatic atrial fibrillation (AF). However, there are limited prospective, nationwide data on patient selection and procedural characteristics. This study describes patient characteristics, techniques, treatment patterns, and safety outcomes of patients undergoing AF ablation. Methods: A total of 3139 patients undergoing AF ablation between 2016 and 2018 in the Get With The Guidelines-Atrial Fibrillation registry from 24 US centers were included. Patient demographics, medical history, procedural details, and complications were abstracted. Differences between paroxysmal and patients with persistent AF were compared using Pearson χ 2 and Wilcoxon rank-sum tests. Results: Patients undergoing AF ablation were predominantly male (63.9%) and White (93.2%) with a median age of 65. Hypertension was the most common comorbidity (67.6%), and patients with persistent AF had more comorbidities than patients with paroxysmal AF. Drug refractory, paroxysmal AF was the most common ablation indication (class I, 53.6%) followed by drug refractory, persistent AF (class I, 41.8%). Radiofrequency ablation with contact force sensing was the most common ablation modality (70.5%); 23.7% of patients underwent cryoballoon ablation. Pulmonary vein isolation was performed in 94.6% of de novo ablations; the most common adjunctive lesions included left atrial roof or posterior/inferior lines, and cavotricuspid isthmus ablation. Complications were uncommon (5.1%) and were life-threatening in 0.7% of cases. Conclusions: More than 98% of AF ablations among participating sites are performed for class I or class IIA indications. Contact force-guided radiofrequency ablation is the dominant technique and pulmonary vein isolation the principal lesion set. In-hospital complications are uncommon and rarely life-threatening.


Heart Rhythm ◽  
2008 ◽  
Vol 5 (6) ◽  
pp. 802-806 ◽  
Author(s):  
Gunnar Klein ◽  
Hanno Oswald ◽  
Ajmal Gardiwal ◽  
Ulrich Lüsebrink ◽  
Christoph Lissel ◽  
...  

QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p < 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.