scholarly journals The Study of Wavelet Analysis in Line Selection of Single-Phase Earth Fault in Medium Voltage Distribution Network

Author(s):  
Changzhi Lv ◽  
Fei Peng
2020 ◽  
Vol 4 (2) ◽  
pp. 127-138
Author(s):  
Ismael Saeed ◽  
Kamal Sheikhyounis

The modeling and calculation of a single phase-to-earth fault of 6 to 35 kV have specific features when compared with circuits with higher nominal voltages. In this paper, a mathematical analysis and modeling of a 3-phase overhead transmission line with distributed parameters consisting of several nominal T-shaped, 3-phase links with concentrated parameters replaced by 1 nominal T-shaped link were carried out. Further analysis showed that not accounting for the distributed nature of the line parameters did not cause significant errors in the assessment of the maximum overvoltage in the arc suppression in single phase-to-earth faults, and that sufficient accuracy insures the representation of the line by only 1 nominal T-shaped, 3-phase link. Such a modeling technique makes it impossible to identify the location of single-phase faults, which is the property of higher harmonic amplification of individual frequencies. Chain equivalent schemas with constant parameters are valid for a single frequency, thereby providing an opportunity to study the nature of the wave process by the discrete selection of parameters. Next in the mathematical representation, we consider the overhead transmission lines as lines with distributed parameters.


Author(s):  
Jevgēnijs Linčiks ◽  
Dzintars Baranovskis

Single Phase Earth Fault Location in the Medium Voltage Distribution NetworksThis paper gives a description of the single phase earth fault location methods in the medium voltage networks. The single phase earth fault location in the medium voltage distribution networks is problematic now. The technical devices which are using in Latvia now do not allow to detect the single phase earth faults fast and high accuracy. Fast earth fault location should be possible by using the equipments which are calculating distance to earth faults. But precisely calculate the distance to the single phase earth faults in the medium voltage networks is very difficult. The paper presents the single earth fault location methods including the calculation methods for fault distance.


Author(s):  
N. S. B. Jamili ◽  
M. R. Adzman ◽  
S. R. A. Rahim ◽  
S. M. Zali ◽  
M. Isa ◽  
...  

This paper focused on studying an algorithm of earth fault location in the medium voltage distribution network. In power system network, most of the earth fault occurs is a single line to ground fault. A medium voltage distribution network with resistance earthing at the main substation and an earth fault attached along the distribution network is modeled in ATP Draw. The generated earth fault is simulated, and the voltage and current signal produced is recorded. The earth fault location algorithm is simulated and tested in MATLAB. The accuracy of the earth fault location algorithm is tested at several locations and fault resistances. A possible correction technique is explained to minimize the error. The results show an improvement fault location distance estimation with minimum error.


Vestnik IGEU ◽  
2015 ◽  
pp. 21-29
Author(s):  
M.S. Al-Homidi ◽  
◽  
Т.Yu. Vinokurova ◽  
O.A. Dobriagina ◽  
V.A. Shuin ◽  
...  