Effect of LOW-molecular-weight Heparin in Reducing Radial Artery Occlusion Rate After Transradial Coronary Catheterization

Author(s):  
2021 ◽  
Author(s):  
Matthaios Didagelos ◽  
Areti Pagiantza ◽  
Thomas Zegkos ◽  
Christos Papanastasiou ◽  
Konstantina Zarra ◽  
...  

Radial artery occlusion (RAO) is the commonest complication of transradial catheterization. There is no evidence-based therapy, in the frame of a randomized control study, for the treatment of RAO. The purpose of the LOW-RAO study is to question the hypothesis if low-molecular-weight heparin is effective in the treatment of RAO after transradial coronary catheterization (both angiography and percutaneous coronary intervention). It is a prospective, open label, randomized controlled trial that will randomize 60 patients with RAO, irrespective of symptoms, into two groups, one receiving anticoagulation with low-molecular-weight heparin and the other receiving no treatment. The primary end point is improvement in radial artery patency rate at 4 weeks after the procedure. Trial registration number: NCT04196309 (ClinicalTrials.gov)


2019 ◽  
Vol 71 (1) ◽  
Author(s):  
Mohamed A. Sadaka ◽  
Waleed Etman ◽  
Walid Ahmed ◽  
Saeed Kandil ◽  
Salah Eltahan

2020 ◽  
Vol 48 (9) ◽  
pp. 030006052095472
Author(s):  
Yingkai Xu ◽  
Yingkai Li ◽  
Jiancai Yu ◽  
Deguang Wang ◽  
Qi Zhao ◽  
...  

Objectives To compare the effectiveness and safety of the Braidin® slender 7 Fr sheath with a standard 6 Fr sheath for treating left main bifurcation disease. Methods From January 2017 to March 2019, 277 patients with left main bifurcation disease who underwent the transradial approach for percutaneous coronary intervention were divided into the slender 7 Fr sheath group (Braidin® slender 7 Fr sheath, n = 154) and standard 6 Fr sheath group (n = 123). Pathological features, surgical effect, and complications were evaluated. Results The rate of using the classic crush technique was significantly higher in the slender 7 Fr sheath group than in the standard 6 Fr sheath group. The slender 7 Fr sheath group had a significantly shorter operation time than the standard 6 Fr sheath group. There were no significant differences in the radial artery occlusion rate after surgery and at 1 month of follow-up between the groups. Multivariate logistic regression analysis showed that 6 Fr and Braidin slender 7 Fr sheaths did not predict radial artery occlusion. Conclusion The Braidin slender 7 Fr sheath has a superior operative process and similar safety for the radial artery as that of the standard 6 Fr sheath for treating left main bifurcation disease.


2020 ◽  
Vol 13 (1) ◽  
Author(s):  
Kashif Ali Hashmi ◽  
Zahid Iqbal ◽  
Atif Ali Hashmi ◽  
Maira Shoaib ◽  
Muhammad Irfan ◽  
...  

Abstract Objectives Radial artery occlusion is a silent complication of a transradial approach to cardiac catheterization that may complicate subsequent transradial procedures in patients undergoing cardiac catheterization. A transradial band reduces vascular complications and provides brisk, powerful and effective haemostasis. The purpose of this study was to assess the frequency of radial artery occlusion in 180 patients undergoing transradial coronary catheterization. Results The median age of the study cohort was 58 years. Radial artery occlusion was found in 14 (7.8%) patients. When stratifying by age group and sex, there was no significant difference in radial artery occlusion between age groups and sex. It was likewise found that comorbidities such as diabetes mellitus, hypertension and smoking, increased the risk of radial artery occlusion however this was observed to be significant only for diabetes mellitus. We therefore conclude that a transradial pneumatic pressure band is an extremely helpful and safe strategy to prevent radial artery occlusion.


Sign in / Sign up

Export Citation Format

Share Document