scholarly journals The sources of innervation of the aortic arch and thoracic aorta in human fetuses

2021 ◽  
Vol 56 (4) ◽  
pp. 468-476
Author(s):  
Galyna Ya. STELMAKH ◽  
◽  
Tatiana V. KHMARA ◽  
Inna V. LUKASHEVYCH ◽  
Volodymyr V. VIZNIUK ◽  
...  
VASA ◽  
2005 ◽  
Vol 34 (3) ◽  
pp. 181-185 ◽  
Author(s):  
Westhoff-Bleck ◽  
Meyer ◽  
Lotz ◽  
Tutarel ◽  
Weiss ◽  
...  

Background: The presence of a bicuspid aortic valve (BAV) might be associated with a progressive dilatation of the aortic root and ascending aorta. However, involvement of the aortic arch and descending aorta has not yet been elucidated. Patients and methods: Magnetic resonance angiography (MRA) was used to assess the diameter of the ascending aorta, aortic arch, and descending aorta in 28 patients with bicuspid aortic valves (mean age 30 ± 9 years). Results: Patients with BAV, but without significant aortic stenosis or regurgitation (n = 10, mean age 27 ± 8 years, n.s. versus control) were compared with controls (n = 13, mean age 33 ± 10 years). In the BAV-patients, aortic root diameter was 35.1 ± 4.9 mm versus 28.9 ± 4.8 mm in the control group (p < 0.01). The diameter of the ascending aorta was also significantly increased at the level of the pulmonary artery (35.5 ± 5.6 mm versus 27.0 ± 4.8 mm, p < 0.001). BAV-patients with moderate or severe aortic regurgitation (n = 18, mean age 32 ± 9 years, n.s. versus control) had a significant dilatation of the aortic root, ascending aorta at the level of the pulmonary artery (41.7 ± 4.8 mm versus 27.0 ± 4.8 mm in control patients, p < 0.001) and, furthermore, significantly increased diameters of the aortic arch (27.1 ± 5.6 mm versus 21.5 ± 1.8 mm, p < 0.01) and descending aorta (21.8 ± 5.6 mm versus 17.0 ± 5.6 mm, p < 0.01). Conclusions: The whole thoracic aorta is abnormally dilated in patients with BAV, particularly in patients with moderate/severe aortic regurgitation. The maximum dilatation occurs in the ascending aorta at the level of the pulmonary artery. Thus, we suggest evaluation of the entire thoracic aorta in patients with BAV.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
S Saitta ◽  
F Sturla ◽  
A Caimi ◽  
A Riva ◽  
MC Palumbo ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Ministry of Publich Health - Ricerca Corrente Introduction Thoracic endovascular aortic repair (TEVAR) represents a well-established alternative to open repair in selected patients. Its preoperative feasibility assessment and planning requires a computational tomography (CT)-based analysis of the geometric aortic features to identify an adequate proximal and distal landing zone (LZ) for endograft deployment. Yet, controversies persist on the definition and methods of measurement of specific geometric features of the LZs, including angulation and tortuosity, which are associated with an increased risk of postoperative endograft failure. In this respect, the development of a preoperative image processing method that provides an automatic and highly reproducible 3D identification of critical geometric features and specific anatomical landmarks, thus reducing the time and uncertainties related to manual segmentation, remains a largely unmet clinical need. In this study, we developed and applied a fully automated pipeline embedding a convolutional neural network (CNN), which feeds on 3D CT images to automatically segment the thoracic aorta, recognize the relevant anatomical landmarks and LZs, and quantifies the geometry of the aortic arch in each proximal LZ s (i.e. 0 to 3). Methods Ninety  CT scans of healthy aortas were retrieved, being the study conceived as a proof of concept analysis. The thoracic aorta was manually segmented by five independent and expert operators. 72 scans with the corresponding ground truth segmentations were randomly selected and used to train the CNN, which was based on a 3D U-Net architecture. The other 18 scans were used to test the CNN-based segmentations. The fully automated pipeline was obtained by integrating the CNN, 3D geometry skeletonization, and processing of the aortic centerline and wall via computational geometry (Figure). The resulting metrics included aortic arch centerline radius of curvature, proximal landing zones (PLZs) maximum diameters, angulation and tortuosity calculated according to previously published work. These parameters were statistically analyzed to compare standard arches vs. arches with a common origin of the innominate and left carotid artery (CILCA), and the different landing zones in each arch type. Results The CNN segmentation yielded a mean Dice score of 0.94 with respect to manual ground truth segmentations. Standard arches were characterized by significantly larger radius of curvature (p = 0.002) and lower tortuosity in zone 3 (p = 0.004) vs. CILCA arches. For both standard and CILCA arches, comparisons among PLZs revealed statistically significant differences in maximum zone diameters (p &lt; 0.0001), angulation (p &lt; 0.0001) and tortuosity (p &lt; 0.0001). Conclusions We developed a CNN-based automated pipeline for the automated, and reliable geometric quantification of standard and CILCA aortic arches. This tool has the potential to support TEVAR pre-procedural planning in a real clinical setting. Abstract Figure. Automatic pipeline scheme


2017 ◽  
Vol 38 ◽  
pp. 233-241 ◽  
Author(s):  
Gaspar Mestres ◽  
Marvin E. Garcia ◽  
Xavier Yugueros ◽  
Rodrigo Urrea ◽  
Paolo Tripodi ◽  
...  

2015 ◽  
Vol 96 (3) ◽  
pp. 377-380
Author(s):  
I R Yagafarov ◽  
R R Sayfullin ◽  
M M Iskhakov ◽  
N V Gazizov ◽  
M G Khatypov ◽  
...  

Spontaneous rupture of the aorta - a violation of the integrity of the aortic wall which is not caused by an aneurysm, trauma, dissection or disintegrating tumor process, and is an acute life-threatening condition. According to some authors, the main cause of spontaneous rupture of the aorta is a penetrating atherosclerotic ulcer of the aorta, which is an ulceration of aortic atherosclerotic plaque leading to penetration of the internal elastic plate in media. We present a case of successful hybrid surgical treatment of patient with spontaneous rupture of the descending thoracic aorta with the formation of para-aortic hematoma and left-sided hemothorax. The patient underwent a hybrid operation - aortic arch and descending thoracic aorta prosthetic repair, subclavian bypass with left subclavian artery ligation, left-sided thoracotomy, and pleural cavity sanitation. No intraoperative complications were observed, the patient was taken off the ventilator on day 2. The control computed tomography performed on day 10, revealed correct and stable stent graft position with no signs of continued bleeding, endoleak. The patient was discharged in satisfactory condition on day 14. Due to the high hospital mortality of open surgery on the thoracic aorta in case of penetrating atherosclerotic ulcers, as well as the predominance of elderly patients with severe comorbidities that contraindicate open surgery using cardiopulmonary bypass, endovascular and hybrid technologies, which are minimally invasive and traumatic, come to the fore. Endovascular prosthetic repair in case of penetrating atherosclerotic ulcer of aortic arch and descending thoracic aorta is an effective and safe procedure in patients at high risk, showing encouraging long-term results.


Author(s):  
John Bozinovski ◽  
Scott A. LeMaire ◽  
Scott A. Weldon ◽  
Joseph S. Coselli

CHEST Journal ◽  
2005 ◽  
Vol 128 (4) ◽  
pp. 416S ◽  
Author(s):  
Konstantinos E. Paziouros ◽  
Stavros Siminelakis ◽  
Sokrates Sismanidis ◽  
Leonidas Disnitsas ◽  
Miltiadis Matsagas ◽  
...  

The Lancet ◽  
1909 ◽  
Vol 174 (4479) ◽  
pp. 8-10
Author(s):  
H.Emlyn Jones ◽  
T.H.C. Benians

Sign in / Sign up

Export Citation Format

Share Document