scholarly journals Novel use of flow diversion for the treatment of aneurysms associated with arteriovenous malformations

2017 ◽  
Vol 42 (6) ◽  
pp. E7 ◽  
Author(s):  
Craig Kilburg ◽  
Philipp Taussky ◽  
M. Yashar S. Kalani ◽  
Min S. Park

The use of flow-diverting stents for intracranial aneurysms has become more prevalent, and flow diverters are now routinely used beyond their initial scope of approval at the proximal internal carotid artery. Although flow diversion for the treatment of cerebral aneurysms is becoming more commonplace, there have been no reports of its use to treat flow-related cerebral aneurysms associated with arteriovenous malformations (AVMs). The authors report the cases of 2 patients whose AVM-associated aneurysms were managed with flow diversion. A 40-year-old woman presented with a history of headaches that led to the identification of an unruptured Spetzler-Martin Grade V, right parietooccipital AVM associated with 3 aneurysms of the ipsilateral internal carotid artery. Initial attempts at balloon-assisted coil embolization of the aneurysms were unsuccessful. The patient underwent placement of a flow-diverting stent across the diseased vessel; a 6-month follow-up angiogram demonstrated complete occlusion of the aneurysms. In the second case, a 57-year-old man presented with new-onset seizures, and an unruptured Spetzler-Martin Grade V, right frontal AVM associated with an irregular, wide-necked anterior communicating artery aneurysm was identified. The patient underwent placement of a flow-diverting stent, and complete occlusion of the aneurysm was observed on a 7-month follow-up angiogram. These 2 cases illustrate the potential for use of flow diversion as a treatment strategy for feeding artery aneurysms associated with AVMs. Because of the need for dual antiplatelet medications after flow diversion in this patient population, however, this strategy should be used judiciously.

2020 ◽  
Vol 26 (4) ◽  
pp. 468-475 ◽  
Author(s):  
Ahmed E Hussein ◽  
Meghana Shownkeen ◽  
Andre Thomas ◽  
Christopher Stapleton ◽  
Denise Brunozzi ◽  
...  

Objective Indications for the treatment of cerebral aneurysms with flow diversion stents are expanding. The current aneurysm occlusion rate at six months ranges between 60 and 80%. Predictability of complete vs. partial aneurysm occlusion is poorly defined. Here, we evaluate the angiographic contrast time-density as a predictor of aneurysm occlusion rate at six months’ post-flow diversion stents. Methods Patients with unruptured cerebral aneurysms proximal to the internal carotid artery terminus treated with single flow diversion stents were included. 2D parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) was used to calculate contrast time-density within the aneurysm and in the proximal adjacent internal carotid artery. The area under the curve ratio between the two regions of interests was assessed at baseline and after flow diversion stents deployment. The area under the curve ratio between completely vs. partially occluded aneurysms at six months’ follow-up was compared. Results Thirty patients with 31 aneurysms were included. Mean aneurysm diameter was 8 mm (range 2–28 mm). Complete occlusion was obtained in 19 aneurysms. Younger patients ( P = 0.006) and smaller aneurysms ( P = 0.046) presented higher chance of complete obliteration. Incomplete occlusion of the aneurysm was more likely if the area under the curve contrast time-density ratio showed absolute ( P = 0.001) and relative percentage ( P = 0.001) decrease after flow diversion stents deployment. Area under ROC curve was 0.85. Conclusion Negative change in the area under the curve ratio indicates less contrast stagnation in the aneurysm and lower chance of occlusion. These data provide a real-time analysis after aneurysm treatment. If validated in larger datasets, this can prompt input to the surgeon to place a second flow diversion stents.


2020 ◽  
Vol 33 (4) ◽  
pp. 297-305
Author(s):  
Mostafa Mahmoud ◽  
Ahmed Farag ◽  
Mostafa Farid ◽  
Ahmed Elserwi ◽  
Amr Abdelsamad ◽  
...  

Introduction The treatment of aneurysms in the internal carotid bifurcation region (ICABR), including aneurysms of the true internal carotid artery (ICA) terminus, those inclined on the proximal A1 or M1 segments or at the most distal pre-bifurcation (ICA) segment, is often challenging in microsurgical clipping and endovascular surgery. Few reports had discussed flow diversion as a therapeutic option for this group. Methods This was a retrospective study analysing flow diversion in treating ICABR aneurysms. Seven patients harbouring eight aneurysms in the ICABR were treated with flow diversion. Five aneurysms were inclined on the proximal A1 segment, and three were located at the most distal pre-bifurcation segment. Patients’ demographics, presentation, procedure technical description, angiographic and clinical follow-up were recorded. PubMed and Ovid MEDLINE were also reviewed for articles published in English, including case series or case reports, for ICABR aneurysms treated with flow diverters. Results All patients except one underwent angiographic follow-up. The Karman–Byrne occlusion scale was used to determine the occlusion rate. All six patients with documented angiographic follow-up had a class IV occlusion score. No permanent or transient neurological or non-neurological complications were encountered in this study. Conclusion Treating ICABR aneurysms using flow diversion is feasible, with a promising angiographic occlusion rate. Further studies are needed to analyse long-term clinical and angiographic results.


2019 ◽  
Vol 10 (01) ◽  
pp. 142-144 ◽  
Author(s):  
Ching-Jen Chen ◽  
M. Rao Patibandla ◽  
Min S. Park ◽  
M. Yashar Kalani

ABSTRACTDespite the widespread use of the pipeline embolization device (PED), no complete aneurysm regrowth after its placement has been reported in the literature. We report the first case of aneurysm regrowth after the initial follow-up angiography demonstrating near-complete occlusion of the aneurysm and remodeling of the vessel with on-label PED use for a large 20 mm × 24 mm × 22 mm (width × depth × height) cavernous segment internal carotid artery (ICA) aneurysm. The patient was treated with two overlapping PED (4.5 mm × 20 mm and 5 mm × 20 mm). Follow-up angiogram at 4 months after treatment demonstrated remodeling of the ICA with a small residual component measuring approximately 7 mm × 8 mm × 7 mm. However, at 10 months after treatment, there was a complete regrowth of the aneurysm with interval growth, now measuring 25 mm × 28 mm × 18 mm. Despite the high aneurysm occlusion rates reported with the PED, persistent aneurysm filling and aneurysm regrowth, although rare, should not be overlooked.


2017 ◽  
Vol 127 (1) ◽  
pp. 81-88 ◽  
Author(s):  
Tibor Becske ◽  
Matthew B. Potts ◽  
Maksim Shapiro ◽  
David F. Kallmes ◽  
Waleed Brinjikji ◽  
...  

OBJECTIVEThe long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODSThe PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTSAt 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONSPipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)


Neurosurgery ◽  
1987 ◽  
Vol 21 (3) ◽  
pp. 296-302 ◽  
Author(s):  
Stuart M. Weil ◽  
Harry R. van Loveren ◽  
Thomas A. Tomsick ◽  
Barbara L. Quallen ◽  
John M. Tew

Abstract Intravascular navigation with nondetachable balloons is a safe, effective method of treatment for inaccessible aneurysms of the internal carotid artery. The rate of ischemic complications is lower than that associated with carotid ligation, and the rate of subsequent hemorrhage is lower than that associated with either carotid ligation or direct clipping. Therefore, for many internal carotid artery aneurysms that originate at or proximal to the ophthalmic artery, the nondetachable balloon technique is an alternative treatment choice. During a 7-year period, 21 aneurysms of the internal carotid artery were treated by the nondetachable balloon technique. All 21 aneurysms were successfully excluded from the circulatory system by either proximal occlusion or trapping of the aneurysm neck. This series consisted of 8 carotid-ophthalmic artery aneurysms, 11 carotid-cavernous aneurysms (6 spontaneous, 5 traumatic), 1 petrous segment aneurysm, and 1 cervical segment aneurysm. At 3 years of follow-up, the following incidences were noted: transient ischemia, 4.7%; infarction, 9.6%; and hemorrhage, 0%. The complications were 1 case of transient hemiparesis and 2 late ischemic events. Fifty per cent of the patients underwent follow-up computed tomography, and thrombosis of the aneurysm was confirmed in all except one case, which was partially thrombosed.


2020 ◽  
pp. neurintsurg-2020-016051
Author(s):  
Federico Cagnazzo ◽  
Raed Ahmed ◽  
Pierre-Henri Lefevre ◽  
Imad Derraz ◽  
Cyril Dargazanli ◽  
...  

BackgroundClinical and hemodynamic consequences of flow diverters extending from the M1 to the internal carotid artery (ICA), covering the A1 segment, have rarely been investigated. We aimed to provide angiographic and clinical data about flow modifications on the covered A1.MethodsConsecutive patients receiving M1-ICA flow diverters for unruptured aneurysms were collected from our prospective database (2014–2020).Results42 A1 arteries covered with a single device were studied. All patients had an angiographic detected contralateral flow from the anterior communicating artery (AcomA). Immediately after flow diversion, 20 (47.6%) covered A1 showed slow flow. During a mean angiographic follow-up of 14 months, 13 (31%) and 22 (52.3%) A1 arteries were occluded and narrowed, respectively. Flow changes were asymptomatic in all cases. Vascular risk factors, sex, oversized compared with not oversized stents, immediate A1 slow flow, age, diameter of the A1, length of follow-up, and platelet inhibition rate were tested as prognosticators of A1 occlusion. Length of the angiographic follow-up was the only predictor of A1 occlusion (p=0.005, OR=3, CI=1.4 to 6.7). There were two device related ischemic events with a 2.3% rate of morbidity (one basal ganglia infarct after coverage of the M1 perforators and one transient acute instent thrombosis).ConclusionsCovering the A1 segment during M1-ICA flow diversion seems relatively safe, if the contralateral flow is assured by the AcomA. Approximately 31% and 52% of the covered A1 showed asymptomatic occlusions and narrowing, respectively. The likelihood of flow modification was proportional to the length of follow-up. Morbidity associated with flow diversion in the ICA terminus region was 2.3%.


2018 ◽  
Vol 10 (11) ◽  
pp. 1074-1078 ◽  
Author(s):  
Maxim Mokin ◽  
Angel Chinea ◽  
Christopher T Primiani ◽  
Zeguang Ren ◽  
Peter Kan ◽  
...  

BackgroundBlood blister aneurysms (BBA) are a rare subset of intracranial aneurysms that represent a therapeutic challenge from both a surgical and endovascular perspective.ObjectiveTo report multicenter experience with flow diversion exclusively for BBA, located at non-branching segments along the anteromedial wall of the supraclinoidal internal carotid artery (ICA).MethodsConsecutive cases of BBA located at non-branching segments along the anteromedial wall of the supraclinoidal ICA treated with flow diversion were included in the final analysis.Results49 patients with 51 BBA of the ICA treated with devices to achieve the flow diversion effect were identified. 43 patients with 45 BBA of the ICA were treated with the pipeline embolization device and were included in the final analysis. Angiographic follow-up data were available for 30 patients (32 aneurysms in total); 87.5% of aneurysms (28/32) showed complete obliteration, 9.4% (3/32) showed reduced filling, and 3.1% (1/32) persistent filling. There was no difference between the size of aneurysm (≤2 mm vs >2 mm) or the use of adjunct coiling and complete occlusion of the aneurysm on follow-up (P=0.354 and P=0.865, respectively). Clinical follow-up data were available for 38 of 43 patients. 68% of patients (26/38) had a good clinical outcome (modified Rankin scale score of 0–2) at 3 months. There were 7 (16%) immediate procedural and 2 (5%) delayed complications, with 1 case of fatal delayed re-rupture after the initial treatment.ConclusionsOur data support the use of a flow diversion technique as a safe and effective therapeutic modality for BBA of the supraclinoid ICA.


2017 ◽  
Vol 23 (6) ◽  
pp. 609-613 ◽  
Author(s):  
Tamás Németh ◽  
László Szakács ◽  
Zsolt Bella ◽  
Valéria Majoros ◽  
Pál Barzó ◽  
...  

Background We report a case of bilateral malignant otitis externa complicated with bilateral petrous internal carotid artery pseudoaneurysms and their successful treatment with a flow diverter. Case report A 68-year-old woman with serious complications of type II diabetes mellitus had malignant otitis externa on the right side. She was treated with combined antibiotic therapy and underwent mastoidectomy for mastoiditis. She presented at our hospital with acute hemorrhage from the right external auditory canal. The emergency computed tomography (CT) angiography revealed a multiobulated pseudoaneurysm at the petrous segment of the right internal carotid artery. The pseudoaneurysm was treated with a 5 × 40-mm Surpass flow diverter. Three months later, she developed a malignant external otitis on the left side. As the infection progressed, a left-sided mastoiditis, a brain abscess, and a pseudoaneurysm at the petrous segment of the left internal carotid artery developed. The pseudoaneurysm caused bleeding from the left ear, and was treated with a 5 × 50-mm Surpass flow diverter. No recurrent bleeding was observed. Four months later, a follow-up angiography showed complete occlusion of the pseudoaneurysm on the left side, but a residual aneurysm could be detected on the right side. One year after the first intervention, the follow-up CT and magnetic resonance angiography revealed the complete occlusion of the aneurysms bilaterally. Conclusion The use of a flow diverter appears to be an efficient and safe method to occlude carotid pseudoaneurysms even in an inflammatory milieu.


Neurosurgery ◽  
2020 ◽  
Vol 87 (4) ◽  
pp. 770-778
Author(s):  
Oluwaseun O Akinduro ◽  
Neethu Gopal ◽  
Tasneem F Hasan ◽  
Emad Nourollah-Zadeh ◽  
Kunal Vakharia ◽  
...  

Abstract BACKGROUND There is a paucity of literature regarding treatment options for extracranial pseudoaneurysms of the internal carotid artery (ICA). To date, Pipeline Embolization Device (PED; Medtronic Inc) use for the treatment of extracranial pseudoaneurysms of the ICA has only been reported from single-center case series. OBJECTIVE To evaluate the safety and efficacy of PED for the treatment of extracranial ICA pseudoaneurysms. METHODS This is a multicenter retrospective study involving 6 high-volume tertiary academic institutions in the United States. We analyzed patients with extracranial ICA pseudoaneurysms treated with PED between January 1, 2011, and January 1, 2019. Clinical assessment was performed pre- and postintervention using the modified Rankin Scale (mRS) and National Institution of Health Stroke Scale (NIHSS) at a minimum of 4-mo follow-up. RESULTS A total of 28 pseudoaneurysms with a mean diameter of 17.7 mm (range: 4.1-52.5 mm) were treated with PED in 24 patients at 6 participating centers. The mean age was 52.1 yr (17-73) ± 14.3 with 14 females and 10 males. At a mean of 21-mo (range 4-66 mo) follow-up, complete occlusion was achieved in 89% (n = 25/28), with near-complete occlusion (>90% occlusion) in the remainder. There were no periprocedural complications. Postprocedure NIHSS was 0 in 88% (n = 21/24) and 1 in 12% (n = 3/24) of patients, and mRS was 0 in 83% (n = 20/24) and 1 in 17% (n = 4/24) of patients. CONCLUSION The treatment of extracranial ICA pseudoaneurysms with PED is safe and effective in selected patients. Randomized controlled trials and prospective cohort studies are needed to establish the role of flow diversion for ICA pseudoaneurysms.


Neurosurgery ◽  
1984 ◽  
Vol 14 (1) ◽  
pp. 78-82 ◽  
Author(s):  
Robert A. Solomon ◽  
Jost W. Michelsen

Abstract We report the case of a patient with a large left subfrontal arteriovenous malformation (AVM) that was supplied by the right internal carotid artery. The anomalous blood supply developed because of complete occlusion of the left internal carotid artery. When the AVM was removed, the patient experienced a hemorrhage into the right basal ganglia. The possibility that this hemorrhage was related to a defect of autoregulation in blood vessels that lie proximal to a large AVM is discussed. Even though this is a unique case, the pathophysiological events that are documented are relevent to the preoperative preparation and surgical management of all patients with AVMs.


Sign in / Sign up

Export Citation Format

Share Document