scholarly journals Endovascular Treatment of Intracranial Aneurysms with Matrix Detachable Coils: Midterm Anatomic Follow-Up from a Prospective Multicenter Registry

2007 ◽  
Vol 29 (1) ◽  
pp. 57-61 ◽  
Author(s):  
L. Pierot ◽  
X. Leclerc ◽  
A. Bonafé ◽  
S. Bracard
Neurosurgery ◽  
2017 ◽  
Vol 64 (CN_suppl_1) ◽  
pp. 228-228
Author(s):  
Erick Michael Westbroek ◽  
Matthew Bender ◽  
Narlin B Beaty ◽  
Bowen Jiang ◽  
Risheng Xu AB ◽  
...  

Abstract INTRODUCTION ISAT demonstrated that coiling is effective for aneurysm treatment in subarachnoid hemorrhage (SAH); however, complete occlusion of wide-necked aneurysms frequently requires adjuvants relatively contraindicated in SAH. As such, a limited “dome occlusive” strategy is often pursued in the setting of SAH. We report a single institution series of coiling of acutely ruptured aneurysms followed by delayed flow diversion for definitive, curative occlusion. METHODS A prospectively collected IRB-approved database was screened for patients with aneurysmal SAH who were initially treated by coil embolization followed by planned flow diversion at a single academic medical institution. Peri-procedural outcomes, complications, and angiographic follow-up were analyzed. RESULTS >50 patients underwent both acute coiling followed by delayed, planned flow diversion. Average aneurysm size on initial presentation was 9.5 mm. Common aneurysm locations included Pcomm (36%), Acomm (30%), MCA (10%), ACA (10%), and vertebral (5%). Dome occlusion was achieved in all cases following initial coiling. Second-stage implantation of a flow diverting stent was achieved in 49/50 cases (98%). Follow-up angiography was available for 33/50 patients (66%), with mean follow-up of 11 months. 27 patients (82%) had complete angiographic occlusion at last follow up. All patients with residual filling at follow-up still had dome occlusion. There were no mortalities (0%). Major complication rate for stage I coiling was 2% (1 patient with intra-procedural aneurysm re-rupture causing increase in a previous ICH). Major complication rate for stage 2 flow diversion was 2% (1 patient with ischemic stroke following noncompliance with dual antiplatelet regimen). Minor complications occurred in 2 additional patients (4%) with transient neurological deficits. CONCLUSION Staged endovascular treatment of ruptured intracranial aneurysms with acute dome-occlusive coil embolization followed by delayed flow diversion is a safe and effective treatment strategy.


2010 ◽  
Vol 16 (3) ◽  
pp. 231-239 ◽  
Author(s):  
L.M. Pyysalo ◽  
L.H. Keski-Nisula ◽  
T.T. Niskakangas ◽  
V.J. Kähärä ◽  
J.E. Öhman

Long-term follow-up studies after endovascular treatment for intracranial aneurysm are still rare and inconclusive. The aim of this study was to assess the long-term clinical and angiographic outcome of patients with endovascularly treated aneurysms. The clinical outcome of all 185 patients with endovascularly treated aneurysms were analyzed and 77 out of 122 surviving patients were examined with MRI and MRA nine to 16 years (mean 11 years) after the initial endovascular treatment. Sixty-three patients were deceased at the time of follow-up. The cause of death was aneurysm-related in 34 (54%) patients. The annual rebleeding rate from the treated aneurysms was 1.3% in the ruptured group and 0.1% in the unruptured group. In long-term follow-up MRA 18 aneurysms (53%) were graded as complete, 11 aneurysms (32%) had neck remnants and five aneurysms (15%) were incompletely occluded in the ruptured group. The occlusion grade was lower in the unruptured group with 20 aneurysms (41%) graded as complete, 11 (22%) had neck remnants and 18 (37%) were incomplete. However, only three aneurysms were unstable during the follow-up period and needed retreatment. Endovascular treatment of unruptured aneurysms showed incomplete angiographic outcome in 37% of cases. However, the annual bleeding rate was as low as 0.1%. Endovascular treatment of ruptured aneurysms showed incomplete angiographic outcome in 15% of cases and the annual rebleeding rate was 1,3%.


Stroke ◽  
2001 ◽  
Vol 32 (suppl_1) ◽  
pp. 356-357
Author(s):  
Colin P Derdeyn ◽  
Christopher J Moran ◽  
DeWitte T Cross ◽  
Michael R Chicoine ◽  
Ralph G Dacey

P98 Purpose: Thrombo-embolic complications associated with the endovascular treatment of intracranial aneurysms with Guglielmi Detachable Coils (GDC) generally occur at the time of the procedure or soon after. The purpose of this report is to determine the frequency of late thrombo-embolic events after GDC. Methods: The records of 189 patients who underwent GDC repair of one or more intracranial aneurysms at our institution were reviewed. The occurence of an ischemic event referrable to a coiled aneurysm was determined by clinical, angiographic, and imaging data. Events occuring within 2 days of the endovascular procedure were considered peri-procedural. Kaplan-Meier analysis of ischemic events over time was performed. Results: Two patients suffered documented thrombo-embolic events. One patient presented 5 weeks after coiling with a transient ischemic attack. Angiography demonstrated thrombus on the surface of the coils at the neck of a large ophthalmic artery aneurysm. The second patient presented with a posterior circulation stroke 4 weeks after coiling of a large superior cerebellar artery aneurysm. Angiography showed no significant proximal disease, with thrombus beginning at the neck of the treated aneurysm and extending out both P1 segments. No intra-procedural problems during the initial coiling had occured with either patient. There was no evidence for protrusion of coils into the parent artery in either patient. Both patients had been receiving daily aspirin (325 mg). One additional patient reporting symptoms suggesting possible ischemics event was evaluated and diagnosed as having atypical migraines. The frequency of a clinical thromboembolic event during the first year after coiling (excluding procedural complications) was 1.1%. Conclusions: Thrombo-embolic events may occur as late as 5 weeks after endovascular treatment of aneurysms with GDC.


2011 ◽  
Vol 17 (4) ◽  
pp. 420-424 ◽  
Author(s):  
W. Yue

We report the clinical and angiographic results of endovascular treatment of unruptured intracranial aneurysms. Over a three-year period, 80 unruptured aneurysms in 74 patients were electively treated with endovascular management. One aneurysm was diagnosed during investigations for a second ruptured aneurysm, 54 aneurysms were incidentally discovered, 18 aneurysms presented with symptoms of mass effect and seven aneurysms presented with symptoms of brain stem ischemia. Mean size of the 80 unruptured aneurysms was 12.5±8.0 mm (range, 2–39 mm). Thirty-six aneurysms (45%) were small (<10 mm), 38 aneurysms (47.5%) were large (10–25 mm), and six aneurysms (7.5%) were giant (25–39 mm). Forty-eight wide-necked aneurysms (60%) were coiled with the aid of a supporting device. The mortality rate was 1.25%, and the overall morbidity was 1.25%. Of these, one of the patients suffered a stroke, leading to severe disability (1.25%). In one patient, the aneurysm ruptured during treatment, resulting in death. Initial aneurysm occlusion was complete (100%) in 76.25% aneurysms, nearly complete (90%–98%) in 10% aneurysms and incomplete (60%–85%) in 13.75% aneurysms. Follow-up angiography was available in 67 patients with 73 treated aneurysms (91.25%) from one to 36 months (mean 9.3 months); partial reopening occurred in 7.5%, mainly large and giant aneurysms (5.5%). Additional coiling was performed in four aneurysms. There were no complications in additional treatments. At 14.1-month clinical follow-up (range, 2 to 36 months), mRS score was 0 in 78.75% patients, 1 in 10% patients, 2 in 8.75% and 3 in 1.25%. There was no aneurysmal rupture during the follow-up period. Endovascular treatment of unruptured intracranial aneurysms has low procedural mortality and morbidity rates.


2019 ◽  
Vol 30 (4) ◽  
pp. 817-826
Author(s):  
Fei Peng ◽  
Xin Feng ◽  
Xin Tong ◽  
Baorui Zhang ◽  
Luyao Wang ◽  
...  

Abstract Purpose To investigate the long-term clinical and angiographic outcomes and their related predictors in endovascular treatment (EVT) of small (<5 mm) ruptured intracranial aneurysms (SRA). Methods The study retrospectively reviewed patients with SRAs who underwent EVT between September 2011 and December 2016 in two Chinese stroke centers. Medical charts and telephone call follow-up were used to identify the overall unfavorable clinical outcomes (OUCO, modified Rankin score ≤2) and any recanalization or retreatment. The independent predictors of OUCO and recanalization were studied using univariate and multivariate analyses. Multivariate Cox proportional hazards models were used to identify the predictors of retreatment. Results In this study 272 SRAs were included with a median follow-up period of 5.0 years (interquartile range 3.5–6.5 years) and 231 patients with over 1171 aneurysm-years were contacted. Among these, OUCO, recanalization, and retreatment occurred in 20 (7.4%), 24 (12.8%), and 11 (7.1%) patients, respectively. Aneurysms accompanied by parent vessel stenosis (AAPVS), high Hunt-Hess grade, high Fisher grade, and intraoperative thrombogenesis in the parent artery (ITPA) were the independent predictors of OUCO. A wide neck was found to be a predictor of recanalization. The 11 retreatments included 1 case of surgical clipping, 6 cases of coiling, and 4 cases of stent-assisted coiling. A wide neck and AAPVS were the related predictors. Conclusion The present study demonstrated relatively favorable clinical and angiographic outcomes in EVT of SRAs in long-term follow-up of up to 5 years. THE AAPVS, as a morphological indicator of the parent artery for both OUCO and retreatment, needs further validation.


2004 ◽  
Vol 10 (3) ◽  
pp. 189-201 ◽  
Author(s):  
H. Henkes ◽  
S. Brew ◽  
S. Felber ◽  
E. Miloslavski ◽  
G. Mogilevski ◽  
...  

Endovascular treatment of intracranial aneurysms with electrolytically detachable coils is often claimed to be based on electrothrombosis, i.e. intra-aneurysmal thrombus formation through applied direct current. Despite the fact that this concept was described more than a century ago, the significance of electrothrombosis in the endovascular treatment of aneurysms remains debatable. Apart from electrothrombosis, mechanical obliteration of the aneurysmal lumen might be one of the many possible mechanisms to explain why and how detachable coils are effective in preventing aneurysms from (re-)rupture. The purpose of this experimental study was to investigate to what extent direct current comparable to that used for coil detachment would influence the adhesion of cellular and liquid blood components to the surface of electrolytically detachable platinum coils. For the in vitro study, electrolytically detachable platinum coils of various types were exposed to stagnant heparinised blood for a total of 16 h, without or with applied direct current for 30 or 90 s (1 mA, 4–6 V, coil as anode). For the in vivo study, electrolytically detachable platinum coils were exposed to flowing blood for 180 s, without or with applied direct current (2 mA, 4–6 V, coil as either anode or cathode), without anti-coagulation and after intravenous administration of 5000 U Heparin and again after the intravenous administration of 500 mg Aspisol in addition to Heparin. After exposure to blood according to these different experimental protocols, the coils were fixed in formalin solution, gold coated and examined by scanning electron microscopy. Thrombus formation on the surface of all unfibred coils was thin and highly variable both from coil to coil, and on different areas of any given coil. The application of direct current minimally enhanced thrombus formation in stagnant blood in vitro, but not in vivo. The cellular and fibrin adhesions on the coil surfaces without and with applied current did not effectively increase the diameter or volume of unfibred coils. Coils with attached nylon fibres, however, proved to be highly thrombogenic without or with application of current. In fibred coils, surface adhesions without and with applied current were voluminous enough to effectively increase the diameter of the coil, potentially important for the process of endosaccular aneurysm occlusion. Electrothrombosis plays no role in the endovascular treatment of intracranial aneurysms with electrolytically detachable coils. This explains why platinum coils with non-electrolytic detachment mechanisms show a similar efficiency and recurrence rate.


Sign in / Sign up

Export Citation Format

Share Document