scholarly journals Evaluating the Performance of Two Solar Domestic Hot Water Systems of the Archetype Sustainable Houses

2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.

2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.


2014 ◽  
Vol 521 ◽  
pp. 539-542
Author(s):  
Da Yu Zheng ◽  
Juan Zheng ◽  
Xiang Yi Guan ◽  
Jia Zheng ◽  
Yi Ming Zhang

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges. A range of published papers and internet research including research work on various solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube) were used. Evaluation of solar collectors performance is critiqued to aid solar technologies make the transition into a specific dominant solar collector. The sources are sorted into sections: finding an academic job, general advice, teaching, research and publishing, tenure and organizations. Provides information about types of solar thermal collectors, indicating what can be added by using evacuated tube collectors instead of flat plate collectors and what can be added by using heat pipe collectors instead of evacuated tubes. Focusing only on three types of solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube). Useful source of information for consultancy and impartial advice for graduate students planning to do research in solar thermal technologies. This paper fulfils identified information about materials and heat transfer properties of materials and manufacturing challenges of these three solar thermal collectors. Describes some changes made to improve the environment which have had unforeseen and adverse effects on safety and the reasons why we need more case histories. Also discusses the reasons why there are no permanent solutions to safety problems and the reasons why senior managers should become more involved in safety problems.


2010 ◽  
Vol 171-172 ◽  
pp. 486-489
Author(s):  
Jie Li

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges. A range of published papers and internet research including research work on various solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube) were used. Evaluation of solar collectors performance is critiqued to aid solar technologies make the transition into a specific dominant solar collector. The sources are sorted into sections: finding an academic job, general advice, teaching, research and publishing, tenure and organizations. Provides information about types of solar thermal collectors, indicating what can be added by using evacuated tube collectors instead of flat plate collectors and what can be added by using heat pipe collectors instead of evacuated tubes. Focusing only on three types of solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube). Useful source of information for consultancy and impartial advice for graduate students planning to do research in solar thermal technologies. This paper fulfils identified information about materials and heat transfer properties of materials and manufacturing challenges of these three solar thermal collectors.


Designs ◽  
2018 ◽  
Vol 2 (4) ◽  
pp. 44
Author(s):  
Jordi Roviras Miñana ◽  
Vicente Sarrablo Moreno

The work presented here aims to demonstrate the technical, architectural, and energy viability of solar thermal collectors made with ceramic materials and their suitability for domestic hot water (DHW) and building heating systems in the Mediterranean climate. The proposal is for the design of a ceramic shell, formed by collector and non-collecting panels, which forms part of the building system itself, and is capable of responding to the basic requirements of a building envelope and harnessing solar energy. Ceramics considerably reduce the final cost of the collector system and offer the new system a variety of compositional and chromatic finishes, occupying the entire building surface and achieving a high degree of architectural integration, although less energy-efficient compared to a conventional metallic collector.


2018 ◽  
Vol 4 (3) ◽  
pp. 25 ◽  
Author(s):  
Daniel Ferrández ◽  
Carlos Moron ◽  
Jorge Pablo Díaz ◽  
Pablo Saiz

ResumenEl actual Código Técnico de la Edificación (CTE) pone de manifiesto la necesidad de cubrir parte de la demanda energética requerida para el abastecimiento de agua caliente sanitaria y climatización de piscinas cubiertas mediante sistemas de aprovechamiento de la energía solar térmica. En este artículo se presenta una comparativa entre las dos principales tipologías de captadores solares térmicos que existen en el mercado: el captador de placa plana y el captador de tubo de vacío, atendiendo a criterios de fracción solar, diseño e integración arquitectónica. Todo ello a fin de discernir en qué circunstancias es más favorable el uso de uno u otro sistema, comparando los resultados obtenidos mediante programas de simulación con la toma de medidas in situ.AbstractThe current Technical Building Code (CTE) highlights the need to cover part of the energy demand required for the supply of hot water and heating of indoor swimming pools using solar thermal systems. This article presents a comparison between the two main types of solar thermal collectors that exist in the market: the flat plate solar collector and the vacuum tube solar collector, according to criteria of solar fraction, design and architectural integration. All of this in order to discern in what circumstances the use of one or the other system is more favourable, comparing the results obtained through simulation programs with the taking of measurements in situ.


2021 ◽  
pp. 1-28
Author(s):  
Laveet Kumar ◽  
Md Hasanuzzaman ◽  
Nasrudin Abd Rahim

Abstract In response to the global quest for a sustainable and environmentally friendly source of energy most scientists' discretion is solar energy, especially solar thermal. However, successful deployment of solar thermal technologies such as solar assisted process heating (SAPH) systems in medium- to large-scale industries is still in quandary due to their inefficacy in raising ample temperatures. Cascaded SAPH system, which is essentially a series combination of two same or different types of thermal collectors, may provide a worthwhile solution to this problem. In this article, performance assessment and comparison of two cascaded SAPH systems have been presented: photovoltaic thermal (PVT) cascaded with flat-plate collector (PVT-FPC) and PVT coupled with heat-pipe evacuated tube collector (PVT-HPETC). Simulation models have been presented for individual FPC, HPETC and PVT as well as PVT cascaded with FPC and HPETC systems in TRNSYS and validated through outdoor experimentation. Both the first and the second laws of thermodynamics have been employed to reveal veritable performance of the systems. Results show that PVT-HPETC delivers better performance with 1625 W thermal energy, 81% energy efficiency and 13.22% exergy efficiency. It cuts 1.37 kg of CO2 on an hourly basis. Cascaded systems can be effective in sustaining industrial process heat requirements.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1829 ◽  
Author(s):  
Piotr Olczak ◽  
Dominika Matuszewska ◽  
Jadwiga Zabagło

In Poland, various solar collector systems are used; among them, the most popular are flat plate collectors (FPCs) and evacuated tube collectors (ETCs). The work presents two installations located at a distance of 80 km apart, working in similar external conditions. One of them contains 120 flat plate collectors and works for the preparation of hot water in a swimming pool building; the second one consists of 32 evacuated tube collectors with a heat pipe and supports the preparation of domestic hot water for a multi-family house. During the comparison of the two quite large solar installations, it was confirmed that the use of evacuated tube solar collectors shows a much better solar energy productivity than flat plate collectors for the absorber area. Higher heat solar gains (by 7.9%) were also observed in the case of the gross collector area. The advantages of evacuated tube collectors are observed mainly during colder periods, which allows for a steadier thermal energy production.


Author(s):  
Enrico Zambolin ◽  
Davide Del Col ◽  
Andrea Padovan

New comparative tests on different types of solar collectors are presented in this paper. Tests have been performed at the solar energy conversion laboratory of the University of Padova. Two standard glazed flat plate collectors and one evacuated tube collector are installed in parallel; the evacuated collector is a direct flow through type with external CPC (compound parabolic concentrator) reflectors. The present test rig allows to make measurements on the flat plate, on the evacuated collector or on both simultaneously, by simply acting on the valves to modify the circuit. In this paper measurements of the performance of the evacuated tube collector and flat plate collectors working at the same conditions are reported. Efficiency in stationary conditions is measured following the standard EN 12975-2 [1] and it is compared with the input/output curves measured for an entire day. The main purpose of the present work is to characterize and to compare the daily energy performance of the two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling).


2013 ◽  
Vol 712-715 ◽  
pp. 1605-1608
Author(s):  
Wen Bo Fang

The high temperature operation of Evacuated Tube Collectors (ETC) and their very low radiant heat losses make them ideal for solar water heating, solar space heating, desiccant air conditioning, thermal driven cooling and industrial process heating applications. The work temperature of common ETC can reach 100~ 250°C. The vacuum tube envelope minimizes heat loss and ensures high collector durability and steady performance. This paper investigates different types of solar thermal collectors and compared them so that the result which the heat loss of ETC is least is obtained. The thermal analysis and performance of ETC are investigated as well.


Sign in / Sign up

Export Citation Format

Share Document